In case of using parametric equalizer, apply preamp of -6.6dB and build filters manually with these parameters. The first 5 filters can be used independently. When using independent subset of filters, apply preamp of -6.5 dB.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 2130 Hz | 0.76 | -2.9 dB |
Peaking | 2271 Hz | 2.98 | 2.1 dB |
Peaking | 2628 Hz | 4.1 | 3.8 dB |
Peaking | 4877 Hz | 2.48 | 7.3 dB |
Peaking | 19080 Hz | 0.45 | -8.3 dB |
Peaking | 70 Hz | 0.24 | -1.0 dB |
Peaking | 6091 Hz | 2.91 | 0.5 dB |
Peaking | 6734 Hz | 4.58 | -3.0 dB |
Peaking | 8304 Hz | 2.57 | 2.9 dB |
Peaking | 13580 Hz | 1.4 | -0.9 dB |
In case of using fixed band (also called graphic) equalizer, apply preamp of -4.0dB (if available) and set gains manually with these parameters.
Type | Fc | Q | Gain |
---|---|---|---|
Peaking | 31 Hz | 1.41 | -0.8 dB |
Peaking | 62 Hz | 1.41 | -0.8 dB |
Peaking | 125 Hz | 1.41 | -0.6 dB |
Peaking | 250 Hz | 1.41 | -0.6 dB |
Peaking | 500 Hz | 1.41 | -0.3 dB |
Peaking | 1000 Hz | 1.41 | -0.7 dB |
Peaking | 2000 Hz | 1.41 | -1.4 dB |
Peaking | 4000 Hz | 1.41 | 4.1 dB |
Peaking | 8000 Hz | 1.41 | 1.0 dB |
Peaking | 16000 Hz | 1.41 | -8.3 dB |