TBW
There are two kinds of monitoring messages received from the device. There is a "CM2024 SUP" message every second which seems to be an overall status and is used to indicate that a battery is ready to charge (and possibly other things I am yet to figure out). The second type of message is a "CM2024 DAT" which returns the status of each slot independently.
First a message like this will arrive
43 4D 32 30 32 34 20 53 55 50 CM2024 SUP
Followed by another fixed length message like this:
02 00 7B 01 EE 02 0D 00 82 78 78 78 78 78 78 78
78 78 78 78 78 78 78 78 78 78 78 78 78 78 78 78
78 98 16 0D 0A
Then when a battery is inserted it will switch to something like:
01 00 7B 01 ED 02 09 00 13 00 01 01 00 02 00 00
00 3C 05 05 00 08 78 78 78 78 78 78 78 78 78 78
78 73 26 0D 0A
So far I have figured out the following:
Offset | Description |
---|---|
01 | Unknown |
02 | Unknown |
03 | Unknown |
04 | Unknown |
05 | Unknown |
06 | Unknown |
07 | Unknown |
08 - 09 | Sequence Counter going from 0x0000 to 0x0257 (0-599) in increments of 13 - Little Endian |
10 | Slot awaiting setup (see slot table) |
11 | Chemistry selected (See chemistry table) |
12 | Program selected (See program table) |
13 | Selected maximum charge current (applicable for NiHM/Cd only) (see charge current table) |
14 | Selected discharge rate (see discharge table) |
15 - 16 | Selected capacity in mAh in units of 1. Little Endian |
17 | SD card status (see table) |
18 | Cool time in minutes |
19 | Unknown |
20 | Unknown |
21 | Unknown |
22 | SD Slot status |
TBW
Value | Description |
---|---|
00 | Slot 1 |
01 | Slot 2 |
02 | Slot 3 |
03 | Slot 4 |
04 | Slot 5 |
05 | Slot 6 |
06 | Slot 7 |
07 | Slot 8 |
08 | Slot A |
09 | Slot B |
Value | Description |
---|---|
01 | NiHM/Cd |
02 | NiZn |
Value | Description |
---|---|
01 | Recharge |
02 | Discharge |
03 | Procharge |
04 | Cycle |
05 | Alive |
06 | Maximize |
Value | Description |
---|---|
00 | Not Applicable (NiZn) |
01 | 500mA |
02 | 1000mA |
03 | 1500mA |
04 | 2000mA |
05 | 2500mA |
06 | 3000mA |
The values are interpreted differently depending on the chemistry
Value | Description |
---|---|
01 | 150mA |
02 | 300mA |
03 | 450mA |
04 | 600mA |
Value | Description |
---|---|
01 | 125mA |
02 | 250mA |
03 | 375mA |
04 | 500mA |
05 | 625mA |
06 | 750mA |
Value | Description |
---|---|
00 | SD off |
01 | Unknown |
02 | On / Ready |
Value | Description |
---|---|
00 | NO CARD |
01 | Unknown |
02 | Unknown |
03 | Unknown |
04 | Unknown |
05 | Unknown |
06 | Unknown |
07 | Inserted |
08 | Ready |