diff --git a/Examples/Test_Cases/BAR_10/BAR_10_DISCON.IN b/Examples/Test_Cases/BAR_10/BAR_10_DISCON.IN index 88bc00d3..b7c95aae 100644 --- a/Examples/Test_Cases/BAR_10/BAR_10_DISCON.IN +++ b/Examples/Test_Cases/BAR_10/BAR_10_DISCON.IN @@ -157,8 +157,8 @@ 0.4189 ! SD_GenSpdCornerFreq - Cutoff Frequency for first order low-pass filter for generator speed for shutdown, [rad/s] ​ 9999.00 ! SD_Time - Shutdown time, [s]​ 1 ! SD_Method - Shutdown method {1: Reduce generator torque and increase blade pitch},​ [-]​ -4500000 ! SD_MaxTorqueRate - Maximum torque rate for shutdown, [Nm/s]​ -0.03480 ! SD_MaxPitchRate - Maximum pitch rate used for shutdown, [rad/s]​ +62000 ! SD_MaxTorqueRate - Maximum torque rate for shutdown, [Nm/s]​ +2.00 ! SD_MaxPitchRate - Maximum pitch rate used for shutdown, [rad/s]​ !------- Floating ----------------------------------------------------------- 1 ! Fl_n - Number of Fl_Kp gains in gain scheduling, optional with default of 1 diff --git a/Examples/Test_Cases/IEA-15-240-RWT-UMaineSemi/DISCON-UMaineSemi.IN b/Examples/Test_Cases/IEA-15-240-RWT-UMaineSemi/DISCON-UMaineSemi.IN index af75b858..1b6063a0 100644 --- a/Examples/Test_Cases/IEA-15-240-RWT-UMaineSemi/DISCON-UMaineSemi.IN +++ b/Examples/Test_Cases/IEA-15-240-RWT-UMaineSemi/DISCON-UMaineSemi.IN @@ -158,7 +158,7 @@ 9999.00 ! SD_Time - Shutdown time, [s]​ 1 ! SD_Method - Shutdown method {1: Reduce generator torque and increase blade pitch},​ [-]​ 4500000 ! SD_MaxTorqueRate - Maximum torque rate for shutdown, [Nm/s]​ -0.03480 ! SD_MaxPitchRate - Maximum pitch rate used for shutdown, [rad/s]​ +0.03490 ! SD_MaxPitchRate - Maximum pitch rate used for shutdown, [rad/s]​ !------- Floating ----------------------------------------------------------- 1 ! Fl_n - Number of Fl_Kp gains in gain scheduling, optional with default of 1 diff --git a/Examples/Test_Cases/MHK_RM1/MHK_RM1_DISCON.IN b/Examples/Test_Cases/MHK_RM1/MHK_RM1_DISCON.IN index e6c9c657..5b47c8df 100644 --- a/Examples/Test_Cases/MHK_RM1/MHK_RM1_DISCON.IN +++ b/Examples/Test_Cases/MHK_RM1/MHK_RM1_DISCON.IN @@ -157,8 +157,8 @@ 0.4189 ! SD_GenSpdCornerFreq - Cutoff Frequency for first order low-pass filter for generator speed for shutdown, [rad/s] ​ 9999.00 ! SD_Time - Shutdown time, [s]​ 1 ! SD_Method - Shutdown method {1: Reduce generator torque and increase blade pitch},​ [-]​ -4500000 ! SD_MaxTorqueRate - Maximum torque rate for shutdown, [Nm/s]​ -0.03480 ! SD_MaxPitchRate - Maximum pitch rate used for shutdown, [rad/s]​ +7800 ! SD_MaxTorqueRate - Maximum torque rate for shutdown, [Nm/s]​ +0.1745 ! SD_MaxPitchRate - Maximum pitch rate used for shutdown, [rad/s]​ !------- Floating ----------------------------------------------------------- 1 ! Fl_n - Number of Fl_Kp gains in gain scheduling, optional with default of 1 diff --git a/Examples/Test_Cases/NREL-5MW/DISCON.IN b/Examples/Test_Cases/NREL-5MW/DISCON.IN index b477013f..7a9d9fbb 100644 --- a/Examples/Test_Cases/NREL-5MW/DISCON.IN +++ b/Examples/Test_Cases/NREL-5MW/DISCON.IN @@ -158,7 +158,7 @@ 9999.00 ! SD_Time - Shutdown time, [s]​ 1 ! SD_Method - Shutdown method {1: Reduce generator torque and increase blade pitch},​ [-]​ 4500000 ! SD_MaxTorqueRate - Maximum torque rate for shutdown, [Nm/s]​ -0.03480 ! SD_MaxPitchRate - Maximum pitch rate used for shutdown, [rad/s]​ +0.03490 ! SD_MaxPitchRate - Maximum pitch rate used for shutdown, [rad/s]​ !------- Floating ----------------------------------------------------------- 1 ! Fl_n - Number of Fl_Kp gains in gain scheduling, optional with default of 1 diff --git a/Examples/Test_Cases/NREL_2p8_127/NREL-2p8-127_DISCON.IN b/Examples/Test_Cases/NREL_2p8_127/NREL-2p8-127_DISCON.IN index e3c844b7..70c515c2 100644 --- a/Examples/Test_Cases/NREL_2p8_127/NREL-2p8-127_DISCON.IN +++ b/Examples/Test_Cases/NREL_2p8_127/NREL-2p8-127_DISCON.IN @@ -157,8 +157,8 @@ 0.4189 ! SD_GenSpdCornerFreq - Cutoff Frequency for first order low-pass filter for generator speed for shutdown, [rad/s] ​ 9999.00 ! SD_Time - Shutdown time, [s]​ 1 ! SD_Method - Shutdown method {1: Reduce generator torque and increase blade pitch},​ [-]​ -4500000 ! SD_MaxTorqueRate - Maximum torque rate for shutdown, [Nm/s]​ -0.03480 ! SD_MaxPitchRate - Maximum pitch rate used for shutdown, [rad/s]​ +22000 ! SD_MaxTorqueRate - Maximum torque rate for shutdown, [Nm/s]​ +0.1745 ! SD_MaxPitchRate - Maximum pitch rate used for shutdown, [rad/s]​ !------- Floating ----------------------------------------------------------- 1 ! Fl_n - Number of Fl_Kp gains in gain scheduling, optional with default of 1