VMware vmxnet3 driver support

This page describes the usage of the VPP's native PCI driver support for VMware vmxnet3 with Contiv/VPP.

Prerequisites

  • vfio-pci driver needs to be loaded (execute modprobe vfio-pci or add vfio-pci into the /etc/modules)

  • on systems without IOMMU, enable unsafe No-IOMMU mode:

# option 1: works immediately, but only until the node is rebooted
echo "1" > /sys/module/vfio/parameters/enable_unsafe_noiommu_mode

# option 2: works after reboot:
echo "options vfio enable_unsafe_noiommu_mode=1" > /etc/modprobe.d/vfio-noiommu.conf
  • PCI devices must be disabled in the DPDK section of the VPP startup config file in /etc/vpp/contiv-vswitch.conf:
dpdk {
  no-pci
}

Configuration

To configure a vmxnte3 interface, MainVppInterface with the prefix vmxnet3- must be configured in the NodeConfig section of the deployment yaml. After the vmxnet3- prefix, the device's PCI address is encoded, e.g. the device with pCI address 0000:0b:00.0 renders into the interface name vmxnet3-0/b/0/0.

Also, since contrary to the DPDK interfaces, the vmxnet3 interfaces support also non-polling interface rx modes, it is a good idea to configure the interrupt or adaptive InterfaceRxMode.

Example configuration:

diff --git a/k8s/contiv-vpp.yaml b/k8s/contiv-vpp.yaml
index 8d1d270a0..4b249c349 100644
--- a/k8s/contiv-vpp.yaml
+++ b/k8s/contiv-vpp.yaml
@@ -26,6 +26,7 @@ data:
     tapInterfaceVersion: 2
     tapv2RxRingSize: 256
     tapv2TxRingSize: 256
+    interfaceRxMode: "adaptive"
     tcpChecksumOffloadDisabled: true
     natExternalTraffic: true
     mtuSize: 1450
@@ -44,6 +45,12 @@ data:
       vppHostSubnetCIDR: 172.30.0.0/16
       vppHostSubnetOneNodePrefixLen: 24
       vxlanCIDR: 192.168.30.0/24
+    nodeConfig:
+    - nodeName: ubuntu-server-1
+      mainVppInterface:
+        interfaceName: vmxnet3-0/b/0/0
+    - nodeName: ubuntu-server-2
+      mainVppInterface:
+        interfaceName: vmxnet3-0/b/0/0
   controller.conf: |
     delayLocalResync: 5000000000
     enablePeriodicHealing: false

Please note that this config can be specified using the helm chart, and the node config also via CRD.

STN Usage

Vmxnet3 VPP driver can also be used in the STN (single NIC) mode. In this case, you need to specify stealInterface as usually. In case that the vmxnet3 kernel driver was used in the host OS before stealing the NIC, vmxnet3 driver will be automatically used.

Example configuration:

diff --git a/k8s/contiv-vpp.yaml b/k8s/contiv-vpp.yaml
index 8d1d270a0..4b249c349 100644
--- a/k8s/contiv-vpp.yaml
+++ b/k8s/contiv-vpp.yaml
@@ -26,6 +26,7 @@ data:
     tapInterfaceVersion: 2
     tapv2RxRingSize: 256
     tapv2TxRingSize: 256
+    interfaceRxMode: "adaptive"
     tcpChecksumOffloadDisabled: true
     natExternalTraffic: true
     mtuSize: 1450
@@ -44,6 +45,12 @@ data:
       vppHostSubnetCIDR: 172.30.0.0/16
       vppHostSubnetOneNodePrefixLen: 24
       vxlanCIDR: 192.168.30.0/24
+    nodeConfig:
+    - nodeName: ubuntu-server-1
+      stealInterface: ens192
   controller.conf: |
     delayLocalResync: 5000000000
     enablePeriodicHealing: false