Notifications
You must be signed in to change notification settings - Fork 0
/
IrrigationControlOld.CR1
191 lines (172 loc) · 5.61 KB
/
IrrigationControlOld.CR1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
'CR1000
'Created by Short Cut (3.0)
'Declare Variables and Units
Public BattV
Public PTemp_C
Public T107_C
Public LeafWet_kohms
Public RTime(9)
public IrrigFlag
public IrrigCount
public CoolingCount
Public WP(4)
Public StartTemp_C(4)
Public Temp1Sec_C(4)
Public Temp30Sec_C(4)
Public DeltaT_C(4)
Public LastGoodValue(4)
Public MeanWP
Public IrrigDurat
Public GoodMeasures
Const Alpha = 1
Const Beta = 0
Units BattV=Volts
Units PTemp_C=Deg C
Units T107_C=Deg C
Units LeafWet_kohms=kilohms
'Define Data Tables
DataTable(PotTables,True,-1)
DataInterval(0,20,min,10)
Average(1,BattV,FP2,False)
Average(1,PTemp_C,FP2,False)
Sample(1,T107_C,FP2)
Average(1,LeafWet_kohms,FP2,False)
Average(1,WP(1),FP2,False)
Average(1,WP(2),FP2,False)
Average(1,WP(3),FP2,False)
Average(1,WP(4),FP2,False)
Average(1,MeanWP,FP2,False)
Average(1,IrrigDurat,FP2,False)
Average(1,DeltaT_C(1),FP2,False)
Average(1,DeltaT_C(2),FP2,False)
Average(1,DeltaT_C(3),FP2,False)
Average(1,DeltaT_C(4),FP2,False)
Average(1,LastGoodValue(1),FP2,False)
Average(1,LastGoodValue(2),FP2,False)
Average(1,LastGoodValue(3),FP2,False)
Average(1,LastGoodValue(4),FP2,False)
EndTable
'Main Program
BeginProg
'Main Scan
dim IrrigHour = 4
dim MaxDurat = 60
dim CoolDurat = 0.66
dim CoolTrigger = 26
Scan(20,min,1,0)
'Default Datalogger Battery Voltage measurement 'BattV'
Battery(BattV)
'Default Wiring Panel Temperature measurement 'PTemp_C'
PanelTemp(PTemp_C,_60Hz)
'109 Temperature Probe measurement 'T109_C'
'Measure thermoster temperature Therm109 (Dest, Reps, SEChan, VX/ExChan, SettlingTime, Integ, Mult, Offset)
Therm107(T107_C,1,16,3,0,_60Hz,1,0)
'237 Leaf Wetness Sensor measurement 'LeafWet_kohms'. BrHalf(Dest, Reps, Range, SEChan, VX/ExChan, MeasPEx, ExmV, RevEx, Settlingtime, Integ, Mult, Offset)
BrHalf(LeafWet_kohms,1,mV25,15,1,1,2500,True,0,250,1,0)
LeafWet_kohms=(1/LeafWet_kohms)-101
'Do soil moisture measurements
'Do soil water potential measurements
'Measure reference temperature'
PanelTemp(PTemp_C,_60Hz)
'Measure Sensors starting temperature
'TCDiff (Dest, Reps, Range, DiffChan, TCType, TRef,RevDiff, SettlingTime, Integ, Mult, Offset)
TCDiff (StartTemp_C(1), 1, mV2_5C, 1, TypeT, PTemp_C,True, 0, _60Hz, 1, 0)
TCDiff (StartTemp_C(2), 1, mV2_5C, 2, TypeT, PTemp_C,True, 0, _60Hz, 1, 0)
TCDiff (StartTemp_C(3), 1, mV2_5C, 3, TypeT, PTemp_C,True, 0, _60Hz, 1, 0)
TCDiff (StartTemp_C(4), 1, mV2_5C, 4, TypeT, PTemp_C,True, 0, _60Hz, 1, 0)
'Switch heater on
PortSet(7,1)
'Pause for a second
Delay(0,1,Sec)
'Take 1 Second measurements
TCDiff (Temp1Sec_C(1), 1, mV2_5C, 1, TypeT, PTemp_C,True, 0, _60Hz, 1, 0)
TCDiff (Temp1Sec_C(2), 1, mV2_5C, 2, TypeT, PTemp_C,True, 0, _60Hz, 1, 0)
TCDiff (Temp1Sec_C(3), 1, mV2_5C, 3, TypeT, PTemp_C,True, 0, _60Hz, 1, 0)
TCDiff (Temp1Sec_C(4), 1, mV2_5C, 4, TypeT, PTemp_C,True, 0, _60Hz, 1, 0)
'Pause for a further 29 seconds
Delay(0,29,Sec)
'Take 30 Second measurements
TCDiff (Temp30Sec_C(1), 1, mV2_5C, 1, TypeT, PTemp_C,True, 0, _60Hz, 1, 0)
TCDiff (Temp30Sec_C(2), 1, mV2_5C, 2, TypeT, PTemp_C,True, 0, _60Hz, 1, 0)
TCDiff (Temp30Sec_C(3), 1, mV2_5C, 3, TypeT, PTemp_C,True, 0, _60Hz, 1, 0)
TCDiff (Temp30Sec_C(4), 1, mV2_5C, 4, TypeT, PTemp_C,True, 0, _60Hz, 1, 0)
'Turn header off
PortSet(7,0)
'Do calculations
DeltaT_C(1) = Temp30Sec_C(1) - Temp1Sec_C(1)
WP(1) = exp(Alpha * DeltaT_C(1) + Beta)
DeltaT_C(2) = Temp30Sec_C(2) - Temp1Sec_C(2)
WP(2) = exp(Alpha * DeltaT_C(2) + Beta)
DeltaT_C(3) = Temp30Sec_C(3) - Temp1Sec_C(3)
WP(3) = exp(Alpha * DeltaT_C(3) + Beta)
DeltaT_C(4) = Temp30Sec_C(4) - Temp1Sec_C(4)
WP(4) = exp(Alpha * DeltaT_C(4) + Beta)
'Calculate mean water potential
MeanWP = 0
'GoodMeasures = 0
dim I
For I = 1 to 4
' If WP(I) = NAN Then
' GoodMeasures += 0
' Else
' MeanWP += WP(I)
' GoodMeasures += 1
' EndIf
if WP(I) = NAN Then
LastGoodValue(I) = LastGoodValue(I)
Else
if WP(I) > 2 Then
LastGoodValue(I) = WP(I)
Endif
Endif
MeanWP += LastGoodValue(I)
Next I
MeanWP = MeanWP/4'GoodMeasures
if MeanWP = NAN Then
MeanWP = 7.5
Endif
'Call Data Tables and Store Data
CallTable(PotTables)
Delay(0,150,mSec) 'Delay(Option, Delay, Units)
'Update time variable
RealTime(RTime(1))
'1=year, 2=month, 3=day of month, 4=hour of day, 5=minutes, 6=seconds, 7=microseconds, 8=day of week, 9=day of year
'Work out how long irrigation should be applied for
dim DurationFactor
DurationFactor = (MeanWP - 2.5)/4
If DurationFactor < 0 Then
DurationFactor = 0
EndIf
If DurationFactor > 1 Then
DurationFactor = 1
EndIf
IrrigDurat = DurationFactor * MaxDurat
'If the time is right apply irrigation
If RTime(4)= IrrigHour and IrrigFlag = 0 and IrrigDurat > 0 Then
PortSet(1,1)
Delay(0,IrrigDurat*0.9,min)
PortSet(1,0)
Delay(0,5,Sec)
PortSet(2,1)
Delay(0,IrrigDurat*1.1,min)
PortSet(2,0)
IrrigFlag = 1
IrrigCount +=1
EndIf
If Rtime(4) = IrrigHour + 1
IrrigFlag = 0
Endif
Delay(0,150,mSec) 'Delay(Option, Delay, Units)
If Rtime(4) >= 10 and Rtime(4) < 18 and T107_C > CoolTrigger
PortSet(1,1)
Delay(0,CoolDurat*0.9,Min)
PortSet(1,0)
Delay(0,5,Sec)
PortSet(2,1)
Delay(0,CoolDurat*1.1,Min)
PortSet(2,0)
CoolingCount +=1
Endif
NextScan
EndProg