# Fan speed control grid based on hard drive temperatures
disk_fan_speed_grid = {
(0, 27): 40, # Temperature from 0°C to 30°C: 40%
(28, 30): 50, # Temperature from 28°C to 30°C: 50%
(31, 34): 60, # Temperature from 31°C to 34°C: 60%
35: 65, # Temperature reach 35°C: 65%
36: 70, # Temperature reach 36°C: 70%
37: 75, # Temperature reach 37°C: 75%
(38, 40): 80, # Temperature from 38°C to 40°C: 80%
(41, 45): 90, # Temperature from 41°C to 45°C: 90%
(46, 60): 100, # Temperature from 46°C to 650°C: 100%
}
# Fan speed control grid based on CPU temperatures
cpu_fan_speed_grid = {
(0, 25): 30, # Temperature from 0°C to 25°C: 30%
(26, 34): 45, # Temperature from 26°C to 34°C: 45%
(35, 40): 55, # Temperature from 35°C to 40°C: 55%
(41, 45): 60, # Temperature from 41°C to 45°C: 60%
46: 65, # Temperature reach 46°C: 65%
47: 70, # Temperature reach 47°C: 70%
(48, 60): 70, # Temperature from 50°C to 60°C: 75%
(61, 80): 85, # Temperature from 61°C to 80°C: 85%
(81, 100): 100 # Temperature from 61°C to 100°C: 100%
}
# If you want to send log to a webhook, put the URL here !
WEBHOOK_URL = ""
# Send a webhook notification when DISK reach a certain temperature
NOTIFICATION_DISK_REACH_HIGH_TEMPERATURE = 40
NOTIFICATION_DISK_REACH_LOW_TEMPERATURE = 10
# Send a webhook notification at least every X minutes if temperature is reach
NOTIFICATION_SEND_EVERY_MINUTE = 5