Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

clarify reference of calc_separatrix_electron_temp #51

Open
hassec opened this issue May 16, 2024 · 1 comment
Open

clarify reference of calc_separatrix_electron_temp #51

hassec opened this issue May 16, 2024 · 1 comment
Assignees
Labels
documentation Improvements or additions to documentation enhancement New feature or request

Comments

@hassec
Copy link
Collaborator

hassec commented May 16, 2024

          Stangeby 2018 has the cold-target approximation. This is the correct form if the target temperature is non-negligible.

Originally posted by @tbody-cfs in #36 (comment)

I think we should add that additional comment to the code then.

Copy link

github-actions bot commented Aug 1, 2024

This issue has not seen any activity in the past 60 days. It is now marked as stale and will be closed in 7 days if no further activity is registered.

@hassec hassec added enhancement New feature or request documentation Improvements or additions to documentation and removed no-issue-activity labels Aug 1, 2024
Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment