Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathgdev_i2c_Sensor_SCD30.py
525 lines (397 loc) · 22.3 KB
/
gdev_i2c_Sensor_SCD30.py
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
#!/usr/bin/python3
# -*- coding: UTF-8 -*-
"""
I2C sensor module SCD30 for CO2 (by NDIR), Temperature, and Humidity
"""
###############################################################################
# This file is part of GeigerLog.
#
# GeigerLog is free software: you can redistribute it and/or modify
# it under the terms of the GNU General Public License as published by
# the Free Software Foundation, either version 3 of the License, or
# (at your option) any later version.
#
# GeigerLog is distributed in the hope that it will be useful,
# but WITHOUT ANY WARRANTY; without even the implied warranty of
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
# GNU General Public License for more details.
#
# You should have received a copy of the GNU General Public License
# along with GeigerLog. If not, see <http://www.gnu.org/licenses/>.
###############################################################################
__author__ = "ullix"
__copyright__ = "Copyright 2016, 2017, 2018, 2019, 2020, 2021, 2022, 2023, 2024"
__credits__ = [""]
__license__ = "GPL3"
from gsup_utils import *
# Reference: Sensirion_CO2_Sensors_SCD30_Interface_Description.pdf - Version 0.91 – D1 – August 2018
# https://www.sensirion.com/de/umweltsensoren/kohlendioxidsensor/kohlendioxidsensoren-scd30/
#
# ATTENTION: SCD30 needs clock-stretching !!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!!
#
# Clock-stretching is NOT available on Raspi!
# Work around is to reduce I2C clock in Raspi to 10 kHz (Default is 100 kHz)
# see: https://learn.adafruit.com/circuitpython-on-raspberrypi-linux/i2c-clock-stretching
#
# Maximal I2C speed is 100 kHz and the master has to support clock stretching. Sensirion recommends
# to operate the SCD30 at a baud rate of 50 kHz or smaller. Clock stretching period in write- and
# read-frames is 30 ms, however, due to internal calibration processes a maximal clock stretching
# of 150 ms may occur once per day. For detailed information to the I2C protocol, refer to NXP
# I2C-bus specification1. SCD30 does not support repeated start condition. Clock stretching is
# necessary to start the microcontroller and might occur before every ACK. I2C master clock
# stretching needs to be implemented according to the NXP specification. The boot-up time is < 2 s.
class SensorSCD30:
"""Code for the Sensirion SCD30 sensor"""
addr = 0x61 # the only option for the SCD30
name = "SCD30"
firmware = "not set" # my device: 3.66 (same as example from manual)
measIntvl = 5 # Measurement Interval in sec (default = 2)
frc = None # Forced Recalibration value (FRC). Default is 400 [ppm]
handle = g.I2CDongle # default for use by 'I2C' device; RaspiI2C defines its own
def __init__(self, addr, I2Chandle=None):
"""Init SensorSCD30 class"""
self.addr = addr
if I2Chandle is not None: self.handle = I2Chandle
def SensorInit(self):
"""Scan for presence, get Serial No, start periodic measurement"""
defname = "SensorInit: " + self.name + ": "
dmsg = "Sensor {:8s} at address 0x{:02X}".format(self.name, self.addr)
# dprint(defname)
setIndent(1)
## check for presence of an I2C device at I2C address
presence = self.handle.DongleIsSensorPresent(self.addr)
if not presence:
# no device found
setIndent(0)
return False, "Did not find any I2C device at address 0x{:02X}".format(self.addr)
else:
# device found
gdprint("Found an I2C device at address 0x{:02X}".format(self.addr))
# NOTE: Reset on the IOW dongle:
# When a reset is done, the first call of firmware after reset
# always results in a "wrong report ID" response, but the firmware
# does come out correct.
#
# Likewise, the first call to self.SCD30DataReady() also comes
# out with "wrong report ID" response, but this CANNOT be changed by
# removing reset!
#
## soft reset
# dprint(defname + "Sensor Reset")
# gdprint(self.SensorReset())
## get firmware version
# dprint(defname + "Get Firmware")
gdprint(self.SCD30getFirmwareVersion())
## get Forced Recalibration value (FRC)
# after power cycle this returns always "400" irrespective of what it really is!
# dprint(defname + "Get Forced Recalibration value (FRC)")
gdprint(defname + "Forced Recalibration value (FRC): {} ppm".format(self.SCD30getFRC()))
## set interval (default is 2 sec)
# dprint(defname + "Set Measurement Interval")
gdprint(self.SCD30MeasurementSetInterval(self.measIntvl))
## stop auto measurements # need to stop first???
# dprint(defname + "SCD30MeasurementStop")
gdprint(self.SCD30MeasurementStop())
## start auto measurements
# dprint(defname + "SCD30MeasurementStart")
gdprint(self.SCD30MeasurementStart())
setIndent(0)
return (True, "Initialized " + dmsg)
def SCD30getFirmwareVersion(self):
"""get the Firmware Version as Major.Minor"""
# 1.4.9 Read firmware version
# Command: 0xD100 , no argument needed
# Wait None in datasheet Version 1.0 – D1 – May 2020
# response: 3 bytes (2 b firmware + 1 bcrc) Firmware version: Major.Minor: 0x03, 0x42 => 3.66 (3.66 is also found on my chip)
# Duration:
# ISS: SCD30getFirmwareVersion: duration: 1.6 ms
start = time.time()
defname = "SCD30getFirmwareVersion: "
tmsg = "FirmWr"
register = 0xD100
readbytes = 3
data = []
wait = 0
answ = self.handle.DongleWriteRead (self.addr, register, readbytes, data, addrScheme=3, msg=tmsg, wait=wait)
if len(answ) != readbytes:
edprint(defname + "Failure reading Serial Number, reponse: ", answ)
return "Not Found"
self.firmware = "{}.{}".format(answ[0], answ[1])
duration = (time.time() - start) * 1000
msg = defname + "got firmware:{} (expecting: 3.66) in:{:0.1f} ms".format(self.firmware, duration)
return msg
def SensorReset(self):
"""Soft Reset SCD30 sensor"""
# 1.4.10 Soft reset
# The SCD30 provides a soft reset mechanism that forces the sensor into the same state as after
# powering up without the need for removing the power-supply. It does so by restarting its system
# controller. After soft reset the sensor will reload all calibrated data. However, it is worth
# noting that the sensor reloads calibration data prior to every measurement by default. This
# includes previously set reference values from ASC or FRC as well as temperature offset values
# last setting. The sensor is able to receive the command at any time, regardless of its internal
# state. In order to start the soft reset procedure the following command should be sent.
# duration: 0.7 ms
start = time.time()
# defname = "SensorReset: " + self.name + ": "
defname = "SensorReset: "
# dprint(defname)
tmsg = "Reset"
register = 0xD304
readbytes = 0
data = []
wrt = self.handle.DongleWriteReg(self.addr, register, readbytes, data, addrScheme=3, msg=tmsg)
# required wait 0.7 ms
time.sleep(0.001) # 1 ms
duration = 1000 * (time.time() - start)
return defname + "{} took {:0.1f} ms".format(tmsg, duration)
def SCD30MeasurementStart(self):
"""needs to be done only once"""
# 1.4.1 Trigger continuous measurement with optional ambient pressure compensation
# Starts continuous measurement of the SCD30 to measure CO 2 concentration, humidity
# and temperature. Measurement data which is not read from the sensor will be overwritten.
# The measurement interval is adjustable via the command documented in chapter 1.4.3,
# initial measurement rate is 2s.
# Continuous measurement status is saved in non-volatile memory. When the sensor is
# powered down while continuous measurement mode is active SCD30 will measure
# continuously after repowering without sending the measurement command. The CO2
# measurement value can be compensated for ambient pressure by feeding the pressure value
# in mBar to the sensor. Setting the ambient pressure will overwrite previous settings of
# altitude compensation. Setting the argument to zero will deactivate the ambient pressure
# compensation (default ambient pressure = 1013.25 mBar). For setting a new ambient pressure
# when continuous measurement is running the whole command has to be written to SCD30.
#
# command: 0x0010 argument
# argument: Format: uint16 Available range: 0 & [700 ... 1400]. Pressure in mBar.
# argument: 0x00 0x00 0x81 : Start continuous measurement without ambient pressure compensation
defname = "SCD30MeasurementStart: "
tmsg = "StartMeas"
register = 0x0010
readbytes = 0
data = [0x00, 0x00, 0x81]
wrt = self.handle.DongleWriteReg(self.addr, register, readbytes, data, addrScheme=3, msg=tmsg)
# return defname + "Done"
return "Measurement START Done"
def SCD30MeasurementStop(self):
"""needs to be done to stop activity"""
# 1.3.2 Stop continuous measurement
# Command: 0x0104, no argument (!!!!!!!!!!!!! in Example 0x0107 is used ????????????)
# ( but in 1.1.2 I2C Sequence there is again 0x0104 )
# response: None
defname = "SCD30MeasurementStop: "
tmsg = "StopMeas"
register = 0x0104
readbytes = 0
data = []
wrt = self.handle.DongleWriteReg(self.addr, register, readbytes, data, addrScheme=3, msg=tmsg)
# return defname + "Done"
return "Measurement STOP Done"
def SCD30MeasurementSetInterval(self, interval):
"""sets the measurement interval. Default is 2 sec"""
defname = "SCD30MeasurementSetInterval: "
# 1.3.3 Set measurement interval
# Sets the interval used by the SCD30 sensor to measure in continuous measurement mode (see chapter 1.3.1).
# Initial value is 2 s. The chosen measurement interval is saved in non-volatile memory and thus is not
# reset to its initial value after power up.
# Command: 0x4600 argument
# argument: Format: unit16 Interval in seconds. Available range: [2 ... 1800] given in 2 bytes
# in the order MSB, LSB, followed by CRC8
# Set measurement interval to 2s: 0x00, 0x02, 0xE3
# Set measurement interval to 5s: 0x00, 0x05, 0x74
# response: None
mi = interval
mi1 = mi >> 8
mi2 = mi & 0xFF
mi3 = getCRC8((mi1, mi2))
tmsg = "SetMeasIntvl"
register = 0x4600
readbytes = 0
# data = [0x00, 0x02, 0xE3] # default = 2 sec
data = [mi1, mi2, mi3] # my setting (5 sec = 0x00, 0x05, 0x74)
wrt = self.handle.DongleWriteReg(self.addr, register, readbytes, data, addrScheme=3, msg=tmsg)
return "Measurement Interval set to: {} sec".format(data[0]<<8 | data[1])
def SCD30getFRC(self):
"""Get the Forced Recalibration value (FRC). Default is 400 ppm"""
# 1.4.6 (De-)Activate Automatic Self-Calibration (ASC)
# Subsegment: Set Forced Recalibration value (FRC)
# Forced recalibration (FRC) is used to compensate for sensor drifts when a reference value of
# the CO 2 concentration in close proximity to the SCD30 is available. For best results, the
# sensor has to be run in a stable environment in continuous mode at a measurement rate of 2s
# for at least two minutes before applying the FRC command and sending the reference value.
# The reference CO2 concentration has to be within the range 400 ppm ≤ c ref (CO2 ) ≤ 2000 ppm.
# Command: 0x5204 argument
# argument: no argument for GETTING the FRC
# response: 3 bytes: FRC MSB, FRC LSB, CRC()
# Default 400ppm: 0x01, 0xc2, 0x50
defname = "SCD30getFRC: "
tmsg = "getFRC"
register = 0x5204
readbytes = 3
data = []
wait = 0
answ = self.handle.DongleWriteRead (self.addr, register, readbytes, data, addrScheme=3, msg=tmsg, wait=wait)
if len(answ) == readbytes: self.frc = answ[0] << 8 | answ[1]
return self.frc
def SCD30setFRC(self, frcvalue):
"""Set the Forced Recalibration value (FRC). Default is 400 ppm"""
# 1.4.6 (De-)Activate Automatic Self-Calibration (ASC)
# Subsegment: Set Forced Recalibration value (FRC)
# Forced recalibration (FRC) is used to compensate for sensor drifts when a reference value of
# the CO 2 concentration in close proximity to the SCD30 is available. For best results, the
# sensor has to be run in a stable environment in continuous mode at a measurement rate of 2s
# for at least two minutes before applying the FRC command and sending the reference value.
# The reference CO2 concentration has to be within the range 400 ppm ≤ c ref (CO2 ) ≤ 2000 ppm.
#
# The most recently used reference value is retained in **volatile** memory and can be read out
# with the command sequence given below. After repowering the sensor, the command will return
# the standard reference value of 400 ppm.
# NOTE: After a restart the reference is read as 400, however the applied reference
# remains in effect but cannot be read anymore
# Command: 0x5204 argument
# argument: SETTING the FRC: Format: uint16 CO2 concentration in ppm: FRC MSB, FRC LSB, CRC8
# Default 400ppm: 0x01, 0xc2, 0x50
# response: None (to read the current calib use SCD30getFRC())
#
defname = "SCD30setFRC: "
frc = int(frcvalue)
frc1 = frc >> 8
frc2 = frc & 0xFF
frc3 = getCRC8((frc1, frc2))
tmsg = "setFRC"
register = 0x5204
readbytes = 0
data = [frc1, frc2, frc3]
wrt = self.handle.DongleWriteReg(self.addr, register, readbytes, data, addrScheme=3, msg=tmsg)
self.frc = self.SCD30getFRC()
return defname + "Done"
def SCD30DataReady(self):
"""get the data-ready status of sensor;
return: 1 True Data are ready
0 False Data are NOT ready
-1 Improper response
"""
# 1.4.4 Get data ready status
# Data ready command is used to determine if a measurement can be read from the sensor’s
# buffer. Whenever there is a measurement available from the internal buffer this command
# returns 1 and 0 otherwise. As soon as the measurement has been read by the return value
# changes to 0. Note that the read header should be send with a delay of > 3ms following
# the write sequence.
# It is recommended to use data ready status byte before readout of the measurement values.
#
# command: 0x0202, no argument needed
# readbytes: 3; MSB, LSB, CRC
start = time.time()
defname = "SCD30DataReady: "
# dprint(defname)
try:
ready = -1 # code for failure
tmsg = "Ready?"
msg = ""
register = 0x0202
readbytes = 3
data = []
wait = 0.003 # wait 3 ms acc to datasheet: Version 1.0 – D1 – May 2020
answ = self.handle.DongleWriteRead (self.addr, register, readbytes, data, addrScheme=3, msg=tmsg, wait=wait)
duration = (time.time() - start) * 1000
if len(answ) == readbytes:
word0 = answ[0] << 8 | answ[1]
if word0 == 1:
ready = True # Data are ready
msg = "30 Data ready"
color = BOLDGREEN
else:
ready = False # Data are NOT ready
msg = "30 Data NOT ready"
color = BOLDRED
msg = defname + " "*70 + "{}{}".format(color, msg)
elif len(answ) == 0:
msg = BOLDRED + "30 No data returned: answ= '{}'".format(answ)
else:
msg = BOLDRED + "30 Improper data returned: answ= '{}'".format(answ)
cdprint(msg + " {:0.1f} ms".format(duration))
except Exception as e:
exceptPrint(e, defname)
return ready
def SensorgetValues(self):
"""Read the CO2, Temp and Humid values if available"""
# 1.4.5 Read measurement
# When new measurement data is available it can be read out with the following command.
# Note that the read header should be send with a delay of > 3ms following the write
# sequence. Make sure that the measurement is completed by reading the data ready status
# bit before read out.
#
# Command: 0x0300, no argument needed. Reads a single measurement of CO2 concentration. (But also the rest!)
# Example with sensor returning: CO2 Concentration = 439 PPM
# Humidity = 48.8 %
# Temperature = 27.2 °C
# CO2 CO2 CO2 CO2 T T T T RH RH RH RH
# MMSB MLSB CRC LMSB LLSB CRC MMSB MLSB CRC LMSB LLSB CRC MMSB MLSB CRC LMSB LLSB CRC
# 0x43 0xDB 0xCB 0x8c 0x2e 0x8f 0x41 0xd9 0x70 0xe7 0xff 0xf5 0x42 0x43 0xbf 0x3a 0x1b 0x74
# Example: The CO2 concentration 400 ppm corresponds to 0x43c80000 in Big-Endian notation.
# measurement duration:
# mit dongle ISS: SCD30: CO2:600.779, Temp:22.575, Humid:33.948 dur: 4.9 ... 5.7 ms (avg: 5.2) 1.0x
# mit dongle ELV: SCD30: CO2:773.918, Temp:27.040, Humid:36.856 dur: 14.5 ... 17.8 ms (avg: 14.8 ms) 2.8x
# mit dongle IOW: SCD30: CO2:807.496, Temp:26.786, Humid:37.331 dur: 47 ... 51 ms (avg: 47.9 ms) 9.2x
# mit dongle FTD: SCD30: CO2:807.496, Temp:26.786, Humid:37.331 dur: xx ... xx ms (avg: xxxx ms) xxxx
# mit dongle ISS: 100 kHz SCD30: dur: 4.9 ... 5.7 ms (avg: 5.2) 1.0x
# mit dongle ISS: 400 kHz SCD30: dur: 3.1 ... 4.2 ms (avg: 3.4) 0.65x 1.53x faster
# @9600 baud
# mit dongle ISS: 100 kHz SCD30: dur: 10.8 ... 12.6 ms (avg: 11.6)
# mit dongle ISS: 400 kHz SCD30: dur: 8.8 ... 10.0 ms (avg: 9.1)
# mit dongle ISS: 1000 kHz SCD30: dur: 8.4 ... 11.1 ms (avg: 9.3) # slower!
start = time.time()
defname = "SensorgetValues: " + self.name + ": "
sgvdata = (g.NAN,) * 3
# cdprint(defname)
setIndent(1)
### does not help
# start = time.time()
# success = False
# while (time.time() - start) < 1:
# time.sleep(0.02)
# dataReady = self.SCD30DataReady()
# if dataReady:
# success = True
# break
# if not success: rdprint(defname, "Giving up")
###
dataReady = self.SCD30DataReady()
if dataReady == 1:
# data are ready
tmsg = "getval"
register = 0x0300
readbytes = 18
data = []
wait = 0.003 # wait 3 ms acc to datasheet: Version 1.0 – D1 – May 2020
answ = self.handle.DongleWriteRead (self.addr, register, readbytes, data, addrScheme=3, msg=tmsg, wait=wait)
#####################################################################################################################
# reference --> CO2 Concentration = 439 PPM, Temperature = 27.2 °C, Humidity = 48.8 %
# answ = [0x43, 0xDB, 0xCB, 0x8c, 0x2e, 0x8f, 0x41, 0xd9, 0x70, 0xe7, 0xff, 0xf5, 0x42, 0x43, 0xbf, 0x3a, 0x1b, 0x74]
#####################################################################################################################
if len(answ) == readbytes:
# Big-Endian notation
# must convert to float explicitely, because numpy data format creates blobs in the SQL database!
data_bytes = np.array(answ[0:2] + answ[3:5], dtype=np.uint8)
co2 = float(data_bytes.view(dtype='>f')[0])
data_bytes = np.array(answ[6:8] + answ[9:11], dtype=np.uint8)
temp = float(data_bytes.view(dtype='>f')[0])
data_bytes = np.array(answ[12:14] + answ[15:17], dtype=np.uint8)
humid = float(data_bytes.view(dtype='>f')[0])
if co2 > 300: sgvdata = (round(co2, 0), round(temp, 3), round(humid, 3)) # first value is most often CO2==0; should be >400, but give it room
msg = True, defname + "CO2:{:6.3f}, Temp:{:6.3f}, Humid:{:6.3f}".format(co2, temp, humid)
else:
msg = False, defname + "Failure reading proper byte count"
else:
# data not ready
msg = False, defname + "Data NOT ready, or failure to get status, or wrong bytecount"
duration = (time.time() - start) * 1000
if msg[0]: gdprint(msg[1] + " dur:{:0.2f} ms".format(duration))
setIndent(0)
return sgvdata
def SensorGetInfo(self):
info = "{}\n" .format("CO2, Temperature, Humidity")
info += "- Address: 0x{:02X}\n" .format(self.addr)
info += "- Firmware: {}\n" .format(self.firmware)
info += "- Measure Intvl: {} sec\n" .format(self.measIntvl)
info += "- Ref. Value: {} ppm\n" .format(self.frc)
info += "- Variables: {}\n" .format(", ".join("{}".format(x) for x in g.Sensors["SCD30"][5]))
return info.split("\n")