Feature: Kia eGMP, Add SOC estimation from cellvoltage min-max #923
+44
−0
Add this suggestion to a batch that can be applied as a single commit.
This suggestion is invalid because no changes were made to the code.
Suggestions cannot be applied while the pull request is closed.
Suggestions cannot be applied while viewing a subset of changes.
Only one suggestion per line can be applied in a batch.
Add this suggestion to a batch that can be applied as a single commit.
Applying suggestions on deleted lines is not supported.
You must change the existing code in this line in order to create a valid suggestion.
Outdated suggestions cannot be applied.
This suggestion has been applied or marked resolved.
Suggestions cannot be applied from pending reviews.
Suggestions cannot be applied on multi-line comments.
Suggestions cannot be applied while the pull request is queued to merge.
Suggestion cannot be applied right now. Please check back later.
What
This PR implements a bandaid solution, SOC% estimation based on cellvoltage min/max
Why
The SOC% is not usable on eGMP packs. To use the batteries, SOC% is mandatory. So we now estimate this value
How
We calculate a SOC% value from the min and max cellvoltages. We then use either one that is the lowest.