Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathCHASSIS-MIB
709 lines (638 loc) · 27.7 KB
/
CHASSIS-MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
CHASSIS-MIB DEFINITIONS ::= BEGIN
-- ctron-chassis-mib.txt
-- Revision: 1.07.00
-- Part Number: 2170548
-- Date: January 31, 1997
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- This module provides authoritative definitions for Cabletron's
-- enterprise-specific chassis MIB.
--
-- This module will be extended, as needed.
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
-- Copyright August 95 Cabletron Systems
IMPORTS
NetworkAddress, Counter, TimeTicks
FROM RFC1155-SMI
chassis
FROM CTRON-MIB-NAMES
DisplayString
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212;
-- This MIB module uses the extended OBJECT-TYPE macro as defined
-- RFC 1212
-- Textual convention
-- DisplayString ::= OCTET STRING
-- This data type is used to model textual information taken from
-- the NVT ASCII character set. By convention, objects with this
-- syntax, unless explicitly stated, are declared as having:
--
-- SIZE (0..255)
-- chType is, in generic terms, similar to sysObjectID in
-- MIB-II. It is defined for the sake of completeness, and
-- in order to negate dependencies on other MIBs.
chType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identifies the type of hub-based or standalone device.
A vendor's authoritative identification of this
chassis or device. By convention, this value is
allocated within the SMI enterprises subtree(1.3.6.1.4.1),
and provides an easy and unambiguous means for
determining `what kind of box' is being managed. If this
information is not present or unknown, its value should
be set to the OBJECT IDENTIFIER { 0 0 }, which is a
syntactically valid object identifier."
::= { chassis 1 }
chBackplaneTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChBackplaneEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of backplanes resident in this chassis."
::= { chassis 2 }
chBackplaneEntry OBJECT-TYPE
SYNTAX ChBackplaneEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A backplane entry containing objects for a particular
backplane."
INDEX { chBackplaneID }
::= { chBackplaneTable 1 }
ChBackplaneEntry ::=
SEQUENCE {
chBackplaneID
INTEGER,
chBackplaneType
OBJECT IDENTIFIER
}
chBackplaneID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An unique value identifying a backplane within the
chassis."
::= { chBackplaneEntry 1 }
chBackplaneType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An authoritative identification that is specific to
the particular media being used to realize the
backplane. For example, if the backplane is realized
by an Ethernet, then the value of this object refers
to a well known OID defined for Ethernet. If this
information is not present or unknown, its value
should be set to OBJECT IDENTIFIER { 0 0 }, which
is a syntactically valid object identifier."
::= { chBackplaneEntry 2 }
chNumSlots OBJECT-TYPE
SYNTAX INTEGER (0..64)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of slots in a chassis. For bounded, slot-less
systems, the value of this object shall be zero(0)."
::= { chassis 3 }
-- Component Table and Definitions
-- Components are instances of functional devices. For
-- example, if two routers and three bridges were installed
-- in a chassis, said chassis accommodates five components.
chCompTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChCompEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of components installed in this chassis."
::= { chassis 4 }
chCompEntry OBJECT-TYPE
SYNTAX ChCompEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A component entry containing objects for a particular
component."
INDEX { chCompID }
::= { chCompTable 1 }
ChCompEntry ::=
SEQUENCE {
chCompID
INTEGER,
chCompAdminStatus
INTEGER,
chCompArg
OCTET STRING,
chCompType
OBJECT IDENTIFIER,
chCompName
DisplayString,
chCompVersion
DisplayString,
chCompTimeStamp
TimeTicks,
chCompAccessPolicy
INTEGER,
chCompBasicCommStr
OCTET STRING,
chCompROCommStr
OCTET STRING,
chCompRWCommStr
OCTET STRING,
chCompSUCommStr
OCTET STRING,
chCompNetAdr
NetworkAddress
}
chCompID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An unique value identifying a component, which includes,
but is not limited to, routers, bridges, and terminal
servers. Multiple instances of a functional device may
exist within the same chassis."
::= { chCompEntry 1 }
chCompAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1), -- none of the following
invalid(2),
enabled(3),
testing(4),
operational(5),
error(6),
disabled(7),
delete(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Provides the state of the given component. A component
is activated by writing a value of enabled(3). Once
enabled, a component enters testing mode, which is
denoted by testing(4), when this object is read. After
tests are complete, the component either enters the
operational(5), or the error(6) state.
The component may be de-activated by writing a value of
disabled(7). In a disabled state, a component does
exist within the given chassis, but is benign. A disabled
component is available for subsequent activation."
::= { chCompEntry 2 }
chCompArg OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A variable that may be passed to a component, when it
is being either enabled or disabled."
::= { chCompEntry 3 }
chCompType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identifies a component within this chassis. A vendor's
authoritative identification of this component type.
By convention, this value is allocated within the SMI
enterprises subtree(1.3.6.1.4.1), and provides an easy
and unambiguous means for determining the component
type. If this information is not present or unknown,
its value should be set to the OBJECT IDENTIFIER { 0 0 },
which is a syntactically valid object identifier."
::= { chCompEntry 4 }
chCompName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of the component."
::= { chCompEntry 5 }
chCompVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of the version/revision level for
this component's software."
::= { chCompEntry 6 }
chCompTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime of this management entity, when
this component was last (re-)initialized."
::= { chCompEntry 7 }
chCompAccessPolicy OBJECT-TYPE
SYNTAX INTEGER {
unknown(1), -- none of the following
invalid(2),
same(3), -- current IP address and
-- community string pair
-- may be used to access
-- this component
otherCommStr(4), -- use community string
-- specified by
-- chCompROCommStr (or
-- chCompRWCommStr), with
-- current IP address to
-- access this component.
-- Community access profile
-- and view are determined
-- by the associated
-- community string that
-- will be used.
other(5) -- use community string
-- specified by
-- chCompROCommStr (or
-- chCompRWCommStr), and
-- address specified by
-- chCompNetAdr to access
-- this component.
-- Community access profile
-- and view are determined
-- by the associated
-- community string that
-- will be used.
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines access information for the pertinent component."
::= { chCompEntry 8 }
chCompBasicCommStr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Read-only community string for the pertinent component.
If the value of chCompAccessPolicy is otherCommStr(4) or
other(5), then this object shall determine the read-only
Community String to be used when accessing this component.
This also defined the basic read only community string to
access MIBs registered to this component."
::= { chCompEntry 9 }
chCompROCommStr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Read-only community string for the pertinent component.
If the value of chCompAccessPolicy is otherCommStr(4) or
other(5), then this object shall determine the read-only
Community String to be used when accessing this component.
This also defined the read only community string to
access MIBs registered to this component."
::= { chCompEntry 10 }
chCompRWCommStr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Read-write community string for the pertinent component.
If the value of chCompAccessPolicy is otherCommStr(4) or
other(5), then this object shall determine the read-write
Community String to be used when accessing this component.
This also defined the read write community string to
access MIBs registered to this component."
::= { chCompEntry 11 }
chCompSUCommStr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Super user community string for the pertinent component.
If the value of chCompAccessPolicy is otherCommStr(4) or
other(5), then this object shall determine the read-write
Community String to be used when accessing this component.
This also defined the read write community string to
access MIBs registered to this component."
::= { chCompEntry 12 }
chCompNetAdr OBJECT-TYPE
SYNTAX NetworkAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"If the value of chCompAccessPolicy is other(5), then this
object shall determine the Network Address to be used to
access this component. In all other cases, a value of
0.0.0.0 shall be returned, when read."
::= { chCompEntry 13 }
-- Slot Table and definitions
-- A module is the physical entity that resides in a chassis slot.
-- A module is also denoted as a board or card. A component may
-- be realized by one or more modules, or one or more components
-- may be realized by the same module.
-- The slot table provides a physical representation of a chassis
-- and its components.
chSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of modules installed in this chassis. A component,
such as a router, may be incorporated on one or more
modules. More than one component may be incorporated on
each module."
::= { chassis 5 }
chSlotEntry OBJECT-TYPE
SYNTAX ChSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A slot entry containing objects for a particular
module."
INDEX { chSlotID, chSlotCompID }
::= { chSlotTable 1 }
ChSlotEntry ::=
SEQUENCE {
chSlotID
INTEGER,
chSlotCompID
INTEGER,
chSlotClass
OBJECT IDENTIFIER,
chSlotModuleType
OBJECT IDENTIFIER,
chSlotModuleName
DisplayString,
chSlotModuleVersion
DisplayString,
chSlotModuleTimeStamp
TimeTicks
}
chSlotID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number containing this module. An unique
value, in the range between 0 and and the value of
chNumSlots."
::= { chSlotEntry 1 }
chSlotCompID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ID value for the component incorporated within this
module. This object is similar to chCompID."
::= { chSlotEntry 2 }
chSlotClass OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The class (or type) of slot. For example, slots that
only allow for power supply modules fall into a class
that is different from slots that allow only interface
cards."
::= { chSlotEntry 3 }
chSlotModuleType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Uniquely defines the module type. A vendor's
authoritative identification for a module. By
convention, this value is allocated within the SMI
enterprises subtree(1.3.6.1.4.1), and provides an easy
and unambiguous means for determining the type of
module."
::= { chSlotEntry 4 }
chSlotModuleName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A textual description of the module."
::= { chSlotEntry 5 }
chSlotModuleVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of the version/revision level for
this module's hardware and firmware."
::= { chSlotEntry 6 }
chSlotModuleTimeStamp OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime for this management entity, when
this module was last (re-)initialized."
::= { chSlotEntry 7 }
-- MIB Table
-- This table provides a list of MIBs that are incorporated in
-- the various components within chassis slots.
chCompMIBTable OBJECT-TYPE
SYNTAX SEQUENCE OF ChCompMIBEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A list of MIBs incorporated on components and their
respective modules, within this chassis."
::= { chassis 6 }
chCompMIBEntry OBJECT-TYPE
SYNTAX ChCompMIBEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A MIB entry containing objects for a MIB that is
realized by a particular module."
INDEX { chCompMIBID, chCompMIBSlotID, chCompMIBCompID }
::= { chCompMIBTable 1 }
ChCompMIBEntry ::=
SEQUENCE {
chCompMIBID
INTEGER,
chCompMIBSlotID
INTEGER,
chCompMIBCompID
INTEGER,
chCompMIBGrpOID
OBJECT IDENTIFIER,
chCompMIBVectorObjectBase
OBJECT IDENTIFIER,
chCompMIBVectorNum
INTEGER,
chCompMIBType
INTEGER,
chCompMIBStatus
INTEGER
}
chCompMIBID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"An unique value identifying an instance of a MIB."
::= { chCompMIBEntry 1 }
chCompMIBSlotID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The slot number for the module that incorporates this
MIB. The value shall be in the range between 0 and
chNumSlots. A non-zero values indicates that the
information presented by this entry is realized only
on the module in the specified slot. A zero value
indicates that this information pertains to the entire
component, without partitioning across modules.
This object is similar to chSlotID."
::= { chCompMIBEntry 2 }
chCompMIBCompID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The component related to this MIB. This object is
similar to chCompID."
::= { chCompMIBEntry 3 }
chCompMIBGrpOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-write
STATUS deprecated
DESCRIPTION
"A reference to a specific MIB group definition. For
example, in the case of MIB-II, the value of this
object may refer to an applicable group, which has
been implemented.
The access is read-write. This will allow network
administrators, to register MIBs for a module that is
known to the chassis management entity, by type alone:
that is, a module for which component information is
unknown."
::= { chCompMIBEntry 4 }
chCompMIBVectorObjectBase OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-write
STATUS deprecated
DESCRIPTION
"A reference to a specific entry of a vector object
within this MIB, associated with the module identified
by chCompMIBSlotID. For example, in the case of a
repeater, the value of this object may refer to an
entry in prtrBasicPortTable. This object facilitates
logical to physical mapping of entities such as
channels, links, interfaces, and ports."
::= { chCompMIBEntry 5 }
chCompMIBVectorNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS deprecated
DESCRIPTION
"A value indicating the number of entries, starting with
the one denoted by chCompMIBVectorObjectBase, that are
realized on this module."
::= { chCompMIBEntry 6 }
chCompMIBType OBJECT-TYPE
SYNTAX INTEGER {
not-instanced(1),
instanced(2)
}
ACCESS read-write
STATUS deprecated
DESCRIPTION
"Depicts whether the MIB in question is instanced
or not.
For reason similar to ones that apply to
chCompMIBGrpOID, the access mode is read-write."
::= { chCompMIBEntry 7 }
chCompMIBStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
invalid(2),
agent(3),
management(4)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Depicts the status of the MIB. If marked as agent
the MIB is generated based upon the components
defined. If marked as management the entry was entered
via a management station. If marked invalid the
entry is to be deleted."
::= { chCompMIBEntry 8 }
chPhysicalChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Depicts the number of physical changes that have occured
to the chassis MIB. This includes additions and
removal of components in the component table."
::= { chassis 7 }
chLogicalChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS deprecated
DESCRIPTION
"Depicts the number of logical changes that have occured
to the chassis MIB. This includes all sets to name
strings etc."
::= { chassis 8 }
chCompGlobalBasicCommStr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..27))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is defined as the base read only community string to
access MIBs on this module. A write to this object will
change all instances of chCompBasicCommStr."
::= { chassis 9 }
chCompGlobalROCommStr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..27))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is defined as the expanded read only community string to
access MIBs on this module. A write to this object will
change all instances of chCompROCommStr."
::= { chassis 10 }
chCompGlobalRWCommStr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..27))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is defined as the read write community string to
access MIBs on this module. A write to this object will
change all instances of chCompRWCommStr."
::= { chassis 11 }
chCompGlobalSUCommStr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(1..27))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is defined as the super user community string to
access MIBs on this module. A write to this object will
change all instances of chCompSUCommStr."
::= { chassis 12 }