-
Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathCTRON-CSMACD-MIB
214 lines (187 loc) · 8.23 KB
/
CTRON-CSMACD-MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
CTRON-CSMACD-MIB DEFINITIONS ::= BEGIN
-- ctron-csmacd-mib.txt
-- Revision: 1.06.00
-- Part Number: 2170554-01
-- Date: August 11, 1995
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- This module provides authoritative definitions for Cabletron's
-- enterprise-specific CSMACD MIB.
--
-- This module will be extended, as required.
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
-- Copyright October 95 Cabletron Systems
-- The contents of this MIB is obsolete. Existing products
-- still utilize it but all future products will implement
-- other MIBs that contain much of this information.
IMPORTS
Counter FROM RFC1155-SMI
ctCSMACD FROM CTRON-MIB-NAMES
OBJECT-TYPE FROM RFC-1212;
-- The fnbCSMACD group
-- Implementation of this group is mandatory for CSMA/CD
-- subsystems on devices that incorporate the FNB.
ctFnbCSMACD OBJECT IDENTIFIER ::= { ctCSMACD 1 }
ctFnbPortConnect OBJECT IDENTIFIER ::= { ctCSMACD 2 }
ctFnbCSMACDTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtFnbCSMACDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of entries that provide connection status of
CSMA/CD subsystems, for the FNB."
::= { ctFnbCSMACD 1 }
ctFnbCSMACDEntry OBJECT-TYPE
SYNTAX CtFnbCSMACDEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the ctFnbCSMACDTable containing objects
that provide FNB connection status for a CSMA/CD
subsystem."
INDEX { ctFnbCSMACDIndex }
::= { ctFnbCSMACDTable 1 }
CtFnbCSMACDEntry ::=
SEQUENCE {
ctFnbCSMACDIndex
INTEGER,
ctFnbConnect
INTEGER,
ctFnbPortChanges
Counter
}
ctFnbCSMACDIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An unique value for each CSMACD subsystem. Its
value ranges between 1 and chassisSlots. The value
for each interface must remain constant, at least,
from one re-initialization of the entity's network
management system to the next re-initialization."
::= { ctFnbCSMACDEntry 1 }
ctFnbConnect OBJECT-TYPE
SYNTAX INTEGER {
connectB(1),
connectC(2),
disconnect(3),
connectA(4),
subnetB(5),
subnetC(6),
multiChannel(7),
frontpanel(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Denotes the connection status of the CSMA/CD board
to the inter-RIC bus. The values of 1, 2, and 4 define
connection status of connect for the subsystem, values 5
and 6 define connection status of subnet connect for
the subsystem, value 8 is defined as a front panel
connection on the module, and a value of 3 defines
disconnect status."
::= { ctFnbCSMACDEntry 2 }
ctFnbPortChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the number of times any port on the
given MIM has changed it's connection to the
inter-RIC bus."
::= { ctFnbCSMACDEntry 3 }
ctFnbPortConnectTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtFnbPortConnectEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table is used to control port
association on ethernet devices. Only
those boards that support port switching
will be listed in this table."
::= { ctFnbPortConnect 1 }
ctFnbPortConnectEntry OBJECT-TYPE
SYNTAX CtFnbPortConnectEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Describes a specific port connection entry."
INDEX { ctFnbPortConnectBoardIndex, ctFnbPortConnectPortIndex }
::= { ctFnbPortConnectTable 1 }
CtFnbPortConnectEntry ::= SEQUENCE {
ctFnbPortConnectBoardIndex
INTEGER,
ctFnbPortConnectPortIndex
INTEGER,
ctFnbPortConnectPortAssignment
INTEGER,
ctFnbPortCompID
INTEGER
}
ctFnbPortConnectBoardIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An instance of a board for which this port
assignment relationship exists."
::= { ctFnbPortConnectEntry 1 }
ctFnbPortConnectPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An instance of a port for which this
assignment relationship exists."
::= { ctFnbPortConnectEntry 2 }
ctFnbPortConnectPortAssignment OBJECT-TYPE
SYNTAX INTEGER {
connectA(1),
connectB(2),
connectC(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The specific channel that the port is
assigned."
::= { ctFnbPortConnectEntry 3 }
ctFnbPortCompID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the component ID as defined in the chassis
MIB that this port is associated with. These
components will be repeater components."
::= { ctFnbPortConnectEntry 4 }
ctFnbPortConnectionChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maintains the number of times any port within
the mangement domain of this MIM changes it's
port assignment."
::= { ctFnbPortConnect 2 }
END