Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathCTRON-FDDI-FNB-MIB
948 lines (811 loc) · 35.9 KB
/
CTRON-FDDI-FNB-MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
493
494
495
496
497
498
499
500
501
502
503
504
505
506
507
508
509
510
511
512
513
514
515
516
517
518
519
520
521
522
523
524
525
526
527
528
529
530
531
532
533
534
535
536
537
538
539
540
541
542
543
544
545
546
547
548
549
550
551
552
553
554
555
556
557
558
559
560
561
562
563
564
565
566
567
568
569
570
571
572
573
574
575
576
577
578
579
580
581
582
583
584
585
586
587
588
589
590
591
592
593
594
595
596
597
598
599
600
601
602
603
604
605
606
607
608
609
610
611
612
613
614
615
616
617
618
619
620
621
622
623
624
625
626
627
628
629
630
631
632
633
634
635
636
637
638
639
640
641
642
643
644
645
646
647
648
649
650
651
652
653
654
655
656
657
658
659
660
661
662
663
664
665
666
667
668
669
670
671
672
673
674
675
676
677
678
679
680
681
682
683
684
685
686
687
688
689
690
691
692
693
694
695
696
697
698
699
700
701
702
703
704
705
706
707
708
709
710
711
712
713
714
715
716
717
718
719
720
721
722
723
724
725
726
727
728
729
730
731
732
733
734
735
736
737
738
739
740
741
742
743
744
745
746
747
748
749
750
751
752
753
754
755
756
757
758
759
760
761
762
763
764
765
766
767
768
769
770
771
772
773
774
775
776
777
778
779
780
781
782
783
784
785
786
787
788
789
790
791
792
793
794
795
796
797
798
799
800
801
802
803
804
805
806
807
808
809
810
811
812
813
814
815
816
817
818
819
820
821
822
823
824
825
826
827
828
829
830
831
832
833
834
835
836
837
838
839
840
841
842
843
844
845
846
847
848
849
850
851
852
853
854
855
856
857
858
859
860
861
862
863
864
865
866
867
868
869
870
871
872
873
874
875
876
877
878
879
880
881
882
883
884
885
886
887
888
889
890
891
892
893
894
895
896
897
898
899
900
901
902
903
904
905
906
907
908
909
910
911
912
913
914
915
916
917
918
919
920
921
922
923
924
925
926
927
928
929
930
931
932
933
934
935
936
937
938
939
940
941
942
943
944
945
946
947
948
CTRON-FDDI-FNB-MIB DEFINITIONS ::= BEGIN
-- CTRON-FDDI-FNB-mib.txt The FDDI FNB backplane control MIB
-- Revision: 1.01.00
-- Date: September 13, 1995
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- This module provides authoritative definitions for Cabletron's
-- enterprise-specific connection MIB.
--
-- This module will be extended, as needed.
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
-- Copyright August 95 Cabletron Systems
IMPORTS
Counter
FROM RFC1155-SMI
ctFDDIFnb
FROM CTRON-MIB-NAMES
DisplayString
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212;
-- DisplayString ::= OCTET STRING
-- This MIB module uses the extended OBJECT-TYPE macro as defined
-- RFC 1212
--====== group definitions ===========
ctFDDIResource OBJECT IDENTIFIER ::= { ctFDDIFnb 1 }
ctFDDINonMux OBJECT IDENTIFIER ::= { ctFDDIFnb 2 }
ctFDDIMux OBJECT IDENTIFIER ::= { ctFDDIFnb 3 }
ctFDDISerialConfig OBJECT IDENTIFIER ::= { ctFDDIFnb 4 }
--===== ctFDDIResource group ========
ctFDDIResourceTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtFDDIResourceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table specifies the physical resources
associated with the FNB and general FNB operation for a
particular module in a particular slot."
::= { ctFDDIResource 1 }
ctFDDIResourceEntry OBJECT-TYPE
SYNTAX CtFDDIResourceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Defines a specific physical resource entry"
INDEX { ctFDDIResourceSlotID, ctFDDIResourceID }
::= { ctFDDIResourceTable 1 }
CtFDDIResourceEntry ::= SEQUENCE {
ctFDDIResourceSlotID
INTEGER,
ctFDDIResourceID
INTEGER,
ctFDDIResourceType
OBJECT IDENTIFIER,
ctFDDIResourceNumbInstance
INTEGER
}
ctFDDIResourceSlotID OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A specific instance of a slot as defined by chSlotID
as defined in the chassis MIB."
::= { ctFDDIResourceEntry 1 }
ctFDDIResourceID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique index that defines a specific physcial resource for
which this relationship exists. The value of this is as
defined by chResourceID in the chassis MIB."
::= { ctFDDIResourceEntry 2 }
ctFDDIResourceType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the type of resource. This is the same value as
chResourceType in the chassis MIB."
::= { ctFDDIResourceEntry 3 }
ctFDDIResourceNumbInstance OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object defines the number of instances of a physical
resource.
Specific resource instances are physically located from
top-to-bottom on a particular module. If there are multiple
'columns' of a resource from the top to the bottom, then
the numbering will start from the left side and proceed
top-to-bottom in each column.
For instance, the first FNB ring will be instance 1 (top
in the chassis) while the second FNB ring is instance 2
(below FNB 1 in the backplane)."
::= { ctFDDIResourceEntry 4 }
-- The ctFDDINonMuxGroup
-- This group pertains to all devices that provide FDDI conectivity
-- which are not multiplexed.
ctFDDINonMuxCapTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtFDDINonMuxCapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table describes all possible capabilities/configurations
for all non-muxed FDDI configurations within the chassis."
::= { ctFDDINonMux 1 }
ctFDDINonMuxCapEntry OBJECT-TYPE
SYNTAX CtFDDINonMuxCapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Describes a particular capability/configuration entry."
INDEX { ctFDDINMSlot, ctFDDINMConfigID }
::= { ctFDDINonMuxCapTable 1 }
CtFDDINonMuxCapEntry ::= SEQUENCE {
ctFDDINMSlot
INTEGER,
ctFDDINMConfigID
INTEGER,
ctFDDINMConfig
DisplayString,
ctFDDINMConfigDesc
DisplayString
}
ctFDDINMSlot OBJECT-TYPE
SYNTAX INTEGER (1..256)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot within the chassis for which this
configuration information is defined."
::= { ctFDDINonMuxCapEntry 1 }
ctFDDINMConfigID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The instance of a particular configuration."
::= { ctFDDINonMuxCapEntry 2 }
ctFDDINMConfig OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object defines a specific valid connection
configuration. It will specify the connection state of all
resource instances. If an instance of a resource is
not specified, then it is disconnected.
Each valid configuration is encoded in an ascii string, using
a specified format for interpretation. The connection
specifications are in groups of four where each group defines
a specific connection configuration. The terms of a connection
group is defined as follows:
1st - The resource ID as defined by
ctFDDIResourceID.
2nd - A specific instance of the physical
resource. This will be a value between 1 and
ctFDDIResourceNumbInstance for the particular
resource ID in the first term. If a resource ID
has more than one specific resource instance, but
the whole resource can be connected, then this
term will have the value '0' to signify all instances
of the resource.
3rd - The connection ID for this specific
physical resource. This value is the same as
ctFDDINMConnectionID, and through the
ctFDDINonMuxConnectionTable maps to a specific
instance of SMT and MAC.
For example if the value of this object is '1.1.2.2.1.1',
then it states that resource 1, instance 1 is connected to
connection ID 2 and resource 2, instance 1 is connected to
connection ID 1 and is inserted into its FDDI ring.
If a valid configuration is no connections then this
object will have a value of '0.0.0'"
::= { ctFDDINonMuxCapEntry 3 }
ctFDDINMConfigDesc OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains a textual description of a valid
connection configuration. This is a more user-friendly
representation of the configuration than the ctFDDINMConfig
object."
::= { ctFDDINonMuxCapEntry 4 }
ctFDDINonMuxCapEnableTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtFDDINonMuxCapEnableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table describes the currently enabled configuration
for each module."
::= { ctFDDINonMux 2 }
ctFDDINonMuxCapEnableEntry OBJECT-TYPE
SYNTAX CtFDDINonMuxCapEnableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Describes a specific configuration enable entry."
INDEX { ctFDDINMEnableSlot }
::= { ctFDDINonMuxCapEnableTable 1 }
CtFDDINonMuxCapEnableEntry ::= SEQUENCE {
ctFDDINMEnableSlot
INTEGER,
ctFDDINMCapEnable
INTEGER
}
ctFDDINMEnableSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A specific slot for which this configuration enable
pertains."
::= { ctFDDINonMuxCapEnableEntry 1 }
ctFDDINMCapEnable OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A specific configuration that is enabled.
Enabling a configuration is done by writing the value of
ctFDDINMConfigID for a specific configuration to this object.
This object, when read, will return the value of
ctFDDINMConfigID for the presently enabled configuration."
::= { ctFDDINonMuxCapEnableEntry 2 }
ctFDDINonMuxConnectionTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtFDDINonMuxConnectionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table defines specific information for each defined
FDDI/FNB connection. This maps the third sub identifier
of ctFDDINMConfig to a particular SMT and MAC instance in
the 1512 FDDI MIB."
::= { ctFDDINonMux 3 }
ctFDDINonMuxConnectionEntry OBJECT-TYPE
SYNTAX CtFDDINonMuxConnectionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Defines a specific configuration connection entry."
INDEX { ctFDDINMConnectionSlot, ctFDDINMConnectionID }
::= { ctFDDINonMuxConnectionTable 1 }
CtFDDINonMuxConnectionEntry ::= SEQUENCE {
ctFDDINMConnectionSlot
INTEGER,
ctFDDINMConnectionID
INTEGER,
ctFDDINMSMT
INTEGER,
ctFDDINMMAC
INTEGER,
ctFDDINMBytes
INTEGER,
ctFDDINMFrames
INTEGER
}
ctFDDINMConnectionSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A specific slot for which this connection entry is
defined."
::= { ctFDDINonMuxConnectionEntry 1 }
ctFDDINMConnectionID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes a specific connection identifier. Valid
connection identifiers are defined by the third
sub-identifier in ctFDDINMConfig as identified by
ctFDDINMCapEnable."
::= { ctFDDINonMuxConnectionEntry 2 }
ctFDDINMSMT OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A specific instance of SMT for which this entry pertains."
REFERENCE
"The IETF RFC FDDI-SMT73-MIB, fddimibSMTIndex"
::= { ctFDDINonMuxConnectionEntry 3 }
ctFDDINMMAC OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A specific MAC that this connection entry pertains."
REFERENCE
"The IETF RFC FDDI-SMT73-MIB, fddimibMACIndex"
::= { ctFDDINonMuxConnectionEntry 4 }
ctFDDINMBytes OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bandwidth utilization in bytes per second."
::= { ctFDDINonMuxConnectionEntry 5 }
ctFDDINMFrames OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bandwidth utilization in frames per second."
::= { ctFDDINonMuxConnectionEntry 6 }
ctFDDINonMuxInterfaceTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtFDDINonMuxInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table describs the number of interfaces defined by
each non multiplexing FDDI FNB module."
::= { ctFDDINonMux 4 }
ctFDDINonMuxInterfaceEntry OBJECT-TYPE
SYNTAX CtFDDINonMuxInterfaceEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A specfic non multiplexing module interface definition."
INDEX { ctFDDINMInterSlot }
::= { ctFDDINonMuxInterfaceTable 1 }
CtFDDINonMuxInterfaceEntry ::= SEQUENCE {
ctFDDINMInterSlot
INTEGER,
ctFDDINMNumbInterfaces
INTEGER
}
ctFDDINMInterSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A specific slot for which this inteface entry is
defined."
::= { ctFDDINonMuxInterfaceEntry 1 }
ctFDDINMNumbInterfaces OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of interfaces defined on this particular
module."
::= { ctFDDINonMuxInterfaceEntry 2 }
-- the ctFDDIMuxGroup
-- This groups controls those devices that perform a FDDI multiplexing
-- operation
ctFDDIMuxCapTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtFDDIMuxCapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table describes all possible configuration/capabilities
defined for a FDDI multiplexing module."
::= { ctFDDIMux 1 }
ctFDDIMuxCapEntry OBJECT-TYPE
SYNTAX CtFDDIMuxCapEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Describes a specfic FDDI multiplexor capability/configuration
entry."
INDEX { ctFDDIMuxSlot, ctFDDIMuxConfig }
::= { ctFDDIMuxCapTable 1 }
CtFDDIMuxCapEntry ::= SEQUENCE {
ctFDDIMuxSlot
INTEGER,
ctFDDIMuxConfigID
INTEGER,
ctFDDIMuxConfig
DisplayString,
ctFDDIMuxConfigDesc
DisplayString
}
ctFDDIMuxSlot OBJECT-TYPE
SYNTAX INTEGER (1..256)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the slot within the chassis for which this
multiplexed capability/configuration entry pertains."
::= { ctFDDIMuxCapEntry 1 }
ctFDDIMuxConfigID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The instance of a particular configuration."
::= { ctFDDIMuxCapEntry 2 }
ctFDDIMuxConfig OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object defines a specific valid connection
configuration. It will specify the connection state of all
resource instances. If an instance of a resource is
not specified, then it is disconnected.
Each valid configuration is encoded in an ascii string, using
a specified format for interpretation. The specific
connections are in groups of four where each group defines a
specific connection configuration. The terms of the connection
group are defined as follows:
1st - Resource ID. The value is the same as
ctFDDIResourceID for a specific resource entry.
2nd - Instance of the resource. This has a value in
the range of 1 to ctFDDIResourceNumbInstance.
3rd - Path of the resource as input to the
multiplexor. Paths are specified as 1
for the primary ring and 2 for the secondary.
4th - This is the multiplexor output channel
that this resource comes out of the multiplexor.
This value is the same as a value of ctFDDIMuxOutID.
5th - Ring Connectivity. This sub-identifier
describes if the given mux-in resource
(sub-identifiers 1-3) is inserted into the backplane
FNB ring. Valid values are 0 for no 1 for yes.
So for example a value of 1.1.1.1.0.2.2.2.2.1 is resource 1,
instance 1 (primary) is on mux-out 1 and it's not inserted;
resource 2, instance 2 (secondary) is on mux-out 2 and
is inserted into the backplane.
If a valid configuration is no connections then this
object will have a value of '0.0.0.0.0'"
::= { ctFDDIMuxCapEntry 3 }
ctFDDIMuxConfigDesc OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This object contains a textual description of a valid
connection configuration. This is a more user-friendly
representation of the configuration than the ctFDDIMuxConfig
object."
::= { ctFDDIMuxCapEntry 4 }
ctFDDIMuxCapEnableTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtFDDIMuxCapEnableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table describes the currently enabled configuration
for each module."
::= { ctFDDIMux 2 }
ctFDDIMuxCapEnableEntry OBJECT-TYPE
SYNTAX CtFDDIMuxCapEnableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Describes a specific configuration enable entry."
INDEX { ctFDDIMuxEnableSlot }
::= { ctFDDIMuxCapEnableTable 1 }
CtFDDIMuxCapEnableEntry ::= SEQUENCE {
ctFDDIMuxEnableSlot
INTEGER,
ctFDDIMuxCapEnable
INTEGER,
ctFDDIMuxMasterPortAssignmentChange
Counter
}
ctFDDIMuxEnableSlot OBJECT-TYPE
SYNTAX INTEGER (1..256)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A specific slot for which this configuration enable
pertains."
::= { ctFDDIMuxCapEnableEntry 1 }
ctFDDIMuxCapEnable OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A specific instance of the configuration that is
enabled.
Setting this object with a specific value of ctFDDIMuxConfigID
enabled that configuration. A request of the value of this
object will return the value of ctFDDIMuxConfigID for the
presently enabled configuration."
::= { ctFDDIMuxCapEnableEntry 2 }
ctFDDIMuxMasterPortAssignmentChange OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Depicts the number of changes to the master port to multiplexor
output mapping."
::= { ctFDDIMuxCapEnableEntry 3 }
ctFDDIMuxOutTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtFDDIMuxOutEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Describes the multiplexor outputs for each of the
FNB multiplexor modules. This maps the multiplexor output
to a specific instance of MAC and SMT in the FDDI MIB."
::= { ctFDDIMux 3 }
ctFDDIMuxOutEntry OBJECT-TYPE
SYNTAX CtFDDIMuxOutEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Describes a particular multiplexor output."
INDEX { ctFDDIMuxOutSlot, ctFDDIMuxOutID }
::= { ctFDDIMuxOutTable 1 }
CtFDDIMuxOutEntry ::= SEQUENCE {
ctFDDIMuxOutSlot
INTEGER,
ctFDDIMuxOutID
INTEGER,
ctFDDIMuxOutMACIndex
INTEGER,
ctFDDIMuxOutSMTIndex
INTEGER,
ctFDDIMuxBytes
INTEGER,
ctFDDIMuxFrames
INTEGER
}
ctFDDIMuxOutSlot OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The given slot for which this multiplexor output information
pertains."
::= { ctFDDIMuxOutEntry 1 }
ctFDDIMuxOutID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The specific instance of the multiplexor output. Instances
of this object are used by the values of ctFDDIMuxConfig."
::= { ctFDDIMuxOutEntry 2 }
ctFDDIMuxOutMACIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MAC instance of this multiplexor output. If this
this object has a value greater than 0, then this
value is the same as fddimibMACIndex. If this object has the
value of 0, the given mux-out does not have a MAC."
REFERENCE
"The IETF RFC FDDI-SMT73-MIB, fddimibMACIndex"
::= { ctFDDIMuxOutEntry 3 }
ctFDDIMuxOutSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identifies the instance of SMT as defined within the
FDDI MIB."
REFERENCE
"The IETF RFC FDDI-SMT73-MIB, fddimibSMTIndex"
::= { ctFDDIMuxOutEntry 4 }
ctFDDIMuxBytes OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bandwidth utilization in bytes per second."
::= { ctFDDIMuxOutEntry 5 }
ctFDDIMuxFrames OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The bandwidth utilization in frames per second."
::= { ctFDDIMuxOutEntry 6 }
ctFDDIMuxMasterPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtFDDIMuxMasterPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of entries that define master ports as they are
defined for the given multiplexed FDDI connection."
::= { ctFDDIMux 4 }
ctFDDIMuxMasterPortEntry OBJECT-TYPE
SYNTAX CtFDDIMuxMasterPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A specific FDDI-FNB multiplexed master port definition."
INDEX { ctFDDIMuxMasterPortSlotID, ctFDDIMuxMasterPortID }
::= { ctFDDIMuxMasterPortTable 1 }
CtFDDIMuxMasterPortEntry ::= SEQUENCE {
ctFDDIMuxMasterPortSlotID
INTEGER,
ctFDDIMuxMasterPortID
INTEGER,
ctFDDIMuxMasterPortAssignment
INTEGER,
ctFDDIMuxMasterPortIndex
INTEGER
}
ctFDDIMuxMasterPortSlotID OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A specific instance of a slot as defined by chSlotID."
::= { ctFDDIMuxMasterPortEntry 1 }
ctFDDIMuxMasterPortID OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique identifier for this specific master port."
::= { ctFDDIMuxMasterPortEntry 2 }
ctFDDIMuxMasterPortAssignment OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Provides the masterport to multiplexor output mapping.
This is as defined by ctFDDIMuxOutMacAssignment."
::= { ctFDDIMuxMasterPortEntry 3 }
ctFDDIMuxMasterPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines a specific port within the FDDI MIBs fddimibPORTTable."
REFERENCE
"The IETF RFC FDDI-SMT73-MIB, fddimibPORTIndex"
::= { ctFDDIMuxMasterPortEntry 4 }
-- The ctFDDISerialControl group
-- This group describes the control over the FDDI serial controlled
-- modules.
ctFDDINumbModules OBJECT-TYPE
SYNTAX INTEGER (0..14)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes the number of modules that are present configurable
thru the serial control portion of this MIB.
This directly reflects the number of rows found within the
ctFDDISerialConfigTable."
::= { ctFDDISerialConfig 1 }
ctFDDISerialConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtFDDISerialConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table describes the adminstrative control over each
of the FNB serial control modules."
::= { ctFDDISerialConfig 2 }
ctFDDISerialConfigEntry OBJECT-TYPE
SYNTAX CtFDDISerialConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Describes the controls over a single FNB serial control
entry."
INDEX { ctFDDISerialSlotID }
::= { ctFDDISerialConfigTable 1 }
CtFDDISerialConfigEntry ::= SEQUENCE {
ctFDDISerialSlotID
INTEGER,
ctFDDISerialAdminStatus
INTEGER,
ctFDDISerialOperStatus
INTEGER
}
ctFDDISerialSlotID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the slot that this FNB serial control module is in.
This is an instance of chSlotID as defined in the chassis MIB."
::= { ctFDDISerialConfigEntry 1 }
ctFDDISerialAdminStatus OBJECT-TYPE
SYNTAX INTEGER {
insertFNB1(1),
insertFNB2(2),
insertFNB1FNB2(3),
bypass(4),
hwControlFNB1(5),
hwControlFNB2(6),
hwControl(7) -- Use hardware control
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Describes the adminstrative desired state for this FNB
serial control module.
insertFNB1(1) - The serial controlled module should be
inserted into FNB-1 and bypass FNB-2.
insertFNB2(2) - The serial contolled module should be
inserted into FNB-2 and bypass FNB-1.
insertFNB1FNB2(3) - Insert the serial controlled module
on both FNBs.
bypass(4) - Bypass the connection to both FNBs.
hwControlFNB1(5) - Use hardware settings for FNB-1.
hwControlFNB2(6) - Use hardware settings for FNB-2.
hwControl(7) - Use the hardware settings for both
FNBs."
::= { ctFDDISerialConfigEntry 2 }
ctFDDISerialOperStatus OBJECT-TYPE
SYNTAX INTEGER {
insertFNB1(1),
insertFNB2(2),
insertFNB1FNB2(3),
bypass(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes the operational status of this FDDI serial
controlled module.
insertFNB1(1) - The serial controlled module is
inserted into FNB-1 and bypassed from FNB-2.
insertFNB2(2) - The serial controlled module is
bypassed from FNB-1 and inserted into FNB-2.
insertFNB1FNB2(3) - The serial controlled module is
inserted into both FNB-1 and FNB-2.
bypass(4) - The serial controlled module is bypassed
from both FNB-1 and FNB-2."
::= { ctFDDISerialConfigEntry 3 }
ctFDDIModuleFPIMTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtFDDIModuleFPIMEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table describes the FPIMs that are on the front panel of
each FDDI serial control module, if that module supports FPIMs."
::= { ctFDDISerialConfig 3 }
ctFDDIModuleFPIMEntry OBJECT-TYPE
SYNTAX CtFDDIModuleFPIMEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Describes a single FDDI FPIM on a module."
INDEX { ctFddiFPIMSlotID, ctFddiFPIM }
::= { ctFDDIModuleFPIMTable 1 }
CtFDDIModuleFPIMEntry ::= SEQUENCE {
ctFddiFPIMSlotID
INTEGER,
ctFddiFPIM
INTEGER,
ctFddiFPIMStatus
INTEGER,
ctFddiFPIMType
OBJECT IDENTIFIER
}
ctFddiFPIMSlotID OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the slot in which this module exists. This
is an instance of chSlotID as found in the chassis MIB."
::= { ctFDDIModuleFPIMEntry 1 }
ctFddiFPIM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the instance of the port for which this definition
is made. Ports are physically located from top-to-bottom on a
particular module. If there are multiple 'columns' of ports
from the top to the bottom, then the numbering will start
from the left side and proceed top-to-bottom in each column."
::= { ctFDDIModuleFPIMEntry 2 }
ctFddiFPIMStatus OBJECT-TYPE
SYNTAX INTEGER {
link(1),
noLink(2),
notSupported(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes the link status of the given FPIM.
A value of link(1) states that a link is present.
A value of noLink(2) states that no link is present.
A value of notSupported(3) means that link status is not
supported by this port and is unknown."
::= { ctFDDIModuleFPIMEntry 4 }
ctFddiFPIMType OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Describes the type of FPIM as found in ctron-oids."
::= { ctFDDIModuleFPIMEntry 5 }
END