-
Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathCTTRAPLOG-MIB
473 lines (426 loc) · 16.3 KB
/
CTTRAPLOG-MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
CTTRAPLOG-MIB DEFINITIONS ::= BEGIN
-- cttraplog-mib.txt
-- Revision: 01.00.02
-- Part Number:
-- Date: July 17, 1998
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- This module provides authoritative definitions for Cabletron's
-- enterprise-specific trap log mib.
--
-- This module will be extended, as required.
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
-- Copyright July 1998 Cabletron Systems
-- PLEASE NOTE: All groups in this mib are optional
IMPORTS
DisplayString
FROM RFC1213-MIB
Counter, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
ctTrapLog
FROM CTRON-MIB-NAMES;
totalNumberOfEntries OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Total number of logged entries for this chassis."
::= { ctTrapLog 1 }
configTable OBJECT-TYPE
SYNTAX SEQUENCE OF ConfigTableEntry
ACCESS not-accessible
STATUS mandatory
::= { ctTrapLog 2 }
configTableEntry OBJECT-TYPE
SYNTAX ConfigTableEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry allows a user to configure the alarm table
for a specific slot. Objects such as Current Entry,
MaxEntries Allowed, and an Enable/Disable switch are
available."
INDEX { slotInChassis }
::= { configTable 1 }
ConfigTableEntry ::=
SEQUENCE {
slotInChassis
INTEGER,
numEntriesLoggeds
Counter,
numEntriesRequested
INTEGER,
numEntriesAllocated
INTEGER,
lastLoggedEntryLogId
INTEGER,
logCommand
INTEGER,
wrap
INTEGER
}
slotInChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Each Slot can be separately configured. This is the
slot number for the configuration entry. "
::= { configTableEntry 1 }
numEntriesLoggeds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the total number of entries looged for this
slot."
::= { configTableEntry 2 }
numEntriesRequested OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum number of entries to store before wrapping
the log on this slot."
::= { configTableEntry 3 }
numEntriesAllocated OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the number of entries allocated to log alarms
on this slot. It will always be less than or equal
to the requested number of entries."
::= { configTableEntry 4 }
lastLoggedEntryLogId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the log id of the last entry logged for this
slot."
::= { configTableEntry 5 }
logCommand OBJECT-TYPE
SYNTAX INTEGER {
clearLog (1)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allows the user to send the log the commands
specified in the enumeration."
::= { configTableEntry 6 }
wrap OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is whether or not this configuration has
wrapped or not."
::= { configTableEntry 7 }
trapLogTable OBJECT-TYPE
SYNTAX SEQUENCE OF TrapLogEntry
ACCESS not-accessible
STATUS mandatory
::= { ctTrapLog 3 }
trapLogEntry OBJECT-TYPE
SYNTAX TrapLogEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each alarm entry is generated from one of the
following sources; (1) a module in one of the main
chassis slots, (2) the EM, (3) or a power supply. "
INDEX { slotChassis,
logId }
::= { trapLogTable 1 }
TrapLogEntry ::=
SEQUENCE {
logId
INTEGER,
nvmpId
INTEGER,
trapLogAcknowledged
INTEGER,
trapLogVarBind
OCTET STRING,
trapLogDescription
DisplayString,
timeLogged
TimeTicks,
filterId
INTEGER,
slotChassis
INTEGER,
trapOID
OBJECT IDENTIFIER,
z80Time
TimeTicks
}
logId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Each slot has a maximium number of log entries that it
can support. Each entry is assigned a monotonically
increasing sequence number. When the maximum number
of entries for a slot is reached, the log wraps. Each
new entry will replace the oldest entry for that slot."
::= { trapLogEntry 1 }
nvmpId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This contains the nvmp id of the trap that occurred."
::= { trapLogEntry 2 }
trapLogAcknowledged OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field is set to 2 if a trap as been acknowledged
from the EM."
::= { trapLogEntry 3 }
trapLogVarBind OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..1500))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is an ASN.1 encoded string representing the pairs
of OID/value items supplied in the original SNMP or
NVMP trap. "
::= { trapLogEntry 4 }
trapLogDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is an internally defined string used to describe
an alarm. Its primary use is for display on the EMs
LCD. A default value will be used for the old trap
calls."
::= { trapLogEntry 5 }
timeLogged OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time the entry was logged. This will be date and
time if possible."
::= { trapLogEntry 6 }
filterId OBJECT-TYPE
SYNTAX INTEGER {
informational (1),
warning (2),
severe (3),
fatal (4),
existing (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This will be used to filter certain alarms. The
criteria is TBD. An example of classification:
informational - requires no intervention. warning -
Does not require immediate intervention. e.g. static
risk severe - Requires immediate intervention. e.g.
power overload. fatal - Requires attention and
module may take corrective action such as reboot. e.g.
Unrecoverable software or hardware error. "
::= { trapLogEntry 7 }
slotChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot of this trap log."
::= { trapLogEntry 8 }
trapOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This OID combines the General Trap code, Specific
Trap code, and the sys object id into one OID."
::= { trapLogEntry 9 }
z80Time OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the time that the Z80 has been up for the
board that sent this trap."
::= { trapLogEntry 10 }
filterTable OBJECT-TYPE
SYNTAX SEQUENCE OF FilterEntry
ACCESS not-accessible
STATUS mandatory
::= { ctTrapLog 4 }
filterEntry OBJECT-TYPE
SYNTAX FilterEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each filter entry is generated from one of the
following sources; (1) a module in one of the main
chassis slots, (2) the EM, (3) or a power supply. "
INDEX { filterSlotInChassis,
filterFilterId,
filterLogId }
::= { filterTable 1 }
FilterEntry ::=
SEQUENCE {
filterLogId
INTEGER,
filterNvmpId
INTEGER,
filterTrapLogAcknowledged
INTEGER,
filterTrapLogVarBind
OCTET STRING,
filterTrapLogDescription
DisplayString,
filterTimeLogged
TimeTicks,
filterFilterId
INTEGER,
filterSlotInChassis
INTEGER,
filterTrapOID
OBJECT IDENTIFIER,
filterZ80Time
TimeTicks
}
filterLogId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Each slot has a maximum number of log entries that it
can support. Each entry is assigned a monotonically
increasing sequence number. When the maximum number of
entries for a slot is reached, the log wraps. Each new
entry willreplace the oldest entry for that slot."
::= { filterEntry 1 }
filterNvmpId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This contains the nvmp id of the trap that was
generated."
::= { filterEntry 2 }
filterTrapLogAcknowledged OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This field is non-zero if a trap has been acknowleged
from the EM."
::= { filterEntry 3 }
filterTrapLogVarBind OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..1500))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is an ASN.1 encoded string representing the pairs
of OID/value items supplied in the original SNMP or
NVMP trap."
::= { filterEntry 4 }
filterTrapLogDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is an internally defined string used to
describe an alarm. It's primary use is for display
on the EMs LCD. A default value will be used for
the old trap calls."
::= { filterEntry 5 }
filterTimeLogged OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time the entry was logged. This will be date
and time if possible."
::= { filterEntry 6 }
filterFilterId OBJECT-TYPE
SYNTAX INTEGER {
informational (1),
warning (2),
severe (3),
fatal (4),
existing (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This will be used tofilter certain alarms. The
criteria is TBD. An example of classification:
informational-requires no intervention. warning -
Does not require immediate intervention. e.g.
statis risk severe - Requires immediate
intervention. e.g. power overload. fatal -
Requires attention and module may take
corrective action such as reboot. e.g. Unrecoverale
software or hardware error."
::= { filterEntry 7 }
filterSlotInChassis OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Slot of this filter entry."
::= { filterEntry 8 }
filterTrapOID OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This OID combines the General Trap code, Specific
Trap code, and the sys object id into one OID."
::= { filterEntry 9 }
filterZ80Time OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of time ticks that have passed since
this boards Z80 processor has been up."
::= { filterEntry 10 }
trapLoggerAgent OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
enabled(2),
standby(3),
elected(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reflects the operational status of the traplogger agent"
::= { ctTrapLog 5 }
END