Notifications
You must be signed in to change notification settings - Fork 1
/
Copy pathSUPERMICRO-HEALTH-MIB
246 lines (212 loc) · 6.68 KB
/
SUPERMICRO-HEALTH-MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
-- *****************************************************************
-- SUPERMICRO-SMI.mib: Super Micro Enterprise Structure of Management Information
--
-- October 26 2001, Software LAB
--
-- Copyright (c) 1993-2001 by Super Micro Computer Inc.
-- All rights reserved.
--
-- *****************************************************************
SUPERMICRO-HEALTH-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Integer32,
Gauge32
FROM SNMPv2-SMI
TEXTUAL-CONVENTION,
DisplayString,
TruthValue
FROM SNMPv2-TC
MODULE-COMPLIANCE,
OBJECT-GROUP
FROM SNMPv2-CONF
smHealth
FROM SUPERMICRO-SMI;
smHealthMIB MODULE-IDENTITY
LAST-UPDATED "200110260000Z"
ORGANIZATION "Super Micro Computer Inc."
CONTACT-INFO
" Software Lab
Postal: 980 Rock Avenue
San Jose, CA 95131
USA
Tel: +1 408 503 8000
E-mail: [email protected]"
DESCRIPTION
"MIB module for monitoring health information"
::= { smHealth 1 }
SMHealthInfoTypes ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Represents the different types of health information that
may be present in a managed device. The following health
information types are currently predefined:
0: fan speed
1: voltage
2: temperature
"
SYNTAX Integer32 (0..64)
smHealthObjects OBJECT IDENTIFIER ::= { smHealthMIB 1 }
smHealthMonitorTable OBJECT-TYPE
SYNTAX SEQUENCE OF SMHealthMonitorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A table of health monitoring entries."
::= { smHealthObjects 1 }
-- ================
smHealthMonitorEntry OBJECT-TYPE
SYNTAX SMHealthMonitorEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the health monitoring table.
Entries cannot be created or deleted via SNMP operations."
INDEX { smHealthMonitorIndex }
::= { smHealthMonitorTable 1 }
SMHealthMonitorEntry ::=
SEQUENCE {
smHealthMonitorIndex Integer32,
smHealthMonitorName DisplayString,
smHealthMonitorType SMHealthInfoTypes,
smHealthMonitorReading Integer32,
smHealthMonitorHighLimit Integer32,
smHealthMonitorLowLimit Integer32,
smHealthMonitorMaxReading Integer32,
smHealthMonitorMinReading Integer32,
smHealthMonitorDivisor Integer32,
smHealthMonitorMonitor TruthValue
}
smHealthMonitorIndex OBJECT-TYPE
SYNTAX Integer32 (1..65535)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The unique value which identifies this Monitor device."
::= { smHealthMonitorEntry 1 }
smHealthMonitorName OBJECT-TYPE
SYNTAX DisplayString
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A textual full name assigned to the Monitor device.
This object is suitable for output to a human operator."
::= { smHealthMonitorEntry 2 }
smHealthMonitorType OBJECT-TYPE
SYNTAX SMHealthInfoTypes
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Identifies this Monitor device type."
::= { smHealthMonitorEntry 3 }
smHealthMonitorReading OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the value from the Monitor device that are
currently in use on the managed device.
FAN reading is in unit of RPM,
Voltage reading is in unit of mV,
Temperture reading is in unit of degree C"
::= { smHealthMonitorEntry 4 }
smHealthMonitorHighLimit OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the value for the High limitation
for the Monitor device that are currently in use on the
managed device.
Apply to Temperature and Voltage deivces only.
Voltage limit is in unit of mV,
Temperture limit is in unit of degree C"
::= { smHealthMonitorEntry 5 }
smHealthMonitorLowLimit OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the value for the Low limitation
for the Monitor device that are currently in use on the
managed device.
FAN limit is in unit of RPM,
Voltage limit is in unit of mV,
Temperture limit is in unit of degree C"
::= { smHealthMonitorEntry 6 }
smHealthMonitorMaxReading OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the value for the possible Maximum reading value
for the Monitor device that are currently in use on the
managed device.
FAN reading is in unit of RPM,
Voltage reading is in unit of mV,
Temperture reading is in unit of degree C"
::= { smHealthMonitorEntry 7 }
smHealthMonitorMinReading OBJECT-TYPE
SYNTAX Integer32 (0..65535)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the value for the possible Minimum reading value
for the Monitor device that are currently in use on the
managed device.
FAN reading is in unit of RPM,
Voltage reading is in unit of mV,
Temperture reading is in unit of degree C"
::= { smHealthMonitorEntry 8 }
smHealthMonitorDivisor OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the value for the Divisor for the Fan
device that are currently in use on the managed device.
Apply to Fan devices only."
::= { smHealthMonitorEntry 9 }
smHealthMonitorMonitor OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Indicates the monitoring status for the Fan device
that are currently in use on the managed device.
1 = monitor, 2=do not monitor"
::= { smHealthMonitorEntry 10 }
-- notifications
smHealthNotifications OBJECT IDENTIFIER ::= { smHealthMIB 2 }
-- (no notifications are currently defined)
-- conformance information
smHealthConformance OBJECT IDENTIFIER ::= { smHealthMIB 3 }
smHealthCompliances OBJECT IDENTIFIER ::= { smHealthConformance 1 }
smHealthGroups OBJECT IDENTIFIER ::= { smHealthConformance 2 }
-- compliance statements
smHealthCompliance MODULE-COMPLIANCE
STATUS current
DESCRIPTION
"The compliance statement for entities which implement
the Supermicro Health Monitoring MIB"
MODULE -- this module
MANDATORY-GROUPS { smHealthMonitorGroup}
::= { smHealthCompliances 1 }
-- units of conformance
smHealthMonitorGroup OBJECT-GROUP
OBJECTS {
smHealthMonitorType,
smHealthMonitorName,
smHealthMonitorReading,
smHealthMonitorHighLimit,
smHealthMonitorLowLimit,
smHealthMonitorMaxReading,
smHealthMonitorMinReading,
smHealthMonitorMonitor
}
STATUS current
DESCRIPTION
"A collection of objects providing Monitor devices."
::= { smHealthGroups 1 }
END