1.2
* dhwt: perform anti-legionella charge only if set
* hcircuit: always compute ambient temperature
* dbus: support reading DHWT charge state
* dbus: provide hcircuit HasAmbientSensor property
* backend mqtt: allow setting subtopics
* log: report counters as unsigned integers
* filecfg: fix offset temperature parsing
* webapp: switch to Python 3, use icons in navbar
* webapp: improve formatting, add success feedback
* webapp: support DHWT
* webapp: support full temperature readings
* webapp: support per-entity runmode override
* webapp: improve PWA integration, fix relative links
* webapp: make every element configurable
* treewide: improve memory footprint
1.1
* rwchcd: implement config checking and using alternative config
* rwchcd: fix memory leaks on program exit path
* rwchcd: ensure only one instance is running
* runtime: implement DHW kill switch
* io: implement non-permanent relay accounting
* io: fix aggregate temperature failure logic
* alarms: implement a notifier
* pumps: implement shared pumps
* hwp1: improve support
* dhwt: implement support for electric thermostat
* dhwt: fix electric operation logic & handling of hs_overtemp
* dhwt: implement electric switchover on heatsource failure
* dhwt: don't engage feedpump if isolation valve is closed
* dhwt: ensure frostfree temperature is honored
* dhwt: implement adaptive heat request
* dhwt: ensure recycling stops when switching system mode
* dhwt: improve handling of isolation valve and feed and recycle pumps
* dhwt: support DHW isolation valve (support external electric failover for integrated tank boiler)
* boiler: Adjust trip anticipation up to full hysteresis
* boiler: fix RM_OFF handling
* boiler: ensure limit_tmax is always honored
* boiler: improve handling of minimum return temp with no mixing valve
* boiler: remove load pump implementation
* boiler: operate from target to target + hysteresis
* hcircuit: tighten transition threshold when indoor sensor is present
* hcircuit: fix floor output logic and improve rate-of-rise limiter
* hcircuit: gracefully handle bilinear computation failure
* hcircuit: implement per-runmode fast cooldown
* hcircuit: fix up transition boost accounting and transition handling
* hcircuit: implement indoor max temp
* valve: remove PI controller jacketing
* valve: PI controller: implement saturated arithmetic
* plant: SYS_OFF/SYS_TEST always take precedence
* plant: move summer maintenance routines to individual entities
* log_statsd: fix log output & IPv6 support
* log_rrd: allow arbitrary log intervals
* dbus: fix temperature read primitive
* webapp: use Bootstrap for webapp and implement basic JSON config
* Cleanup API, add usage(), reorganize code
1.0
* Initial release