About ionospheric correction of clock bias #31
Comments
I believe the reason for that is the clock reference used for precise products differs from the one used for SSR corrections. Therefore, it is necessary to convert them into a common reference frame before making the subsequent comparison.
However, I find it is hard to look up clock reference of each satellite systems (GECJ) of all satellite-based PPP service (HAS, B2b, CLAS, and MADOCA). The official Interface Control Documents (ICDs) seems to not explicitly provide that information. |
Yes, correctly! The different clock reference signals are the reason for applying the biases. The idea was to pick two reference signals and apply the corresponding biases from the SSR corrections and the IGS reference product, to make the clock offsets comparable. It is not necessary for the user to know the clock reference signals, because they are supposed to apply the corresponding observable-specific bias (OSB) for each observation. If there is no bias for a signal, this measurement cannot be processed. It is the responsibility of the provider of the corrections to make sure that orbit, clock offset and bias corrections are consistent irrespective of which signals are processed on the user side. The use of OSBs therefore makes the processing on the user side much easier. |
Dear Dr. hirokawa and Dr. AndreHauschild, Thank you very much for your explanations! However, is the GLONASS also possible to apply ionospheric free code bias correction to compare the clock bias in the same way? Thank you very much! |
Dear MayHarryWang, You are welcome! Your question on GLONASS is difficult to answer. In general, the answer is yes, because GLONASS is parametrized in exactly the same way in the SSR correction and therefore, at least formally, the method described above also applies. However, as you rightfully point out, the FDMA signals of GLONASS introduce a strong dependency of the biases on the user's equipment, which puts a limit on how well the biases can be eliminated with satellite-dependent bias corrections only. |
Dear Dr. AndreHauschild, Yes, this is why I'm questionable about the difference between precise product and SSR-corrected ephemeris of GLONASS. But, as you mentioned, I think it might still feasible to preview the assessment of SSR product. Thank you very much for your work! It really helps me a lot! |
It is assumed that the user processes the signals C1C and C2W, therefore the iono-free combination of the corresponding biases is applied to make the clock comparable for these signals. Again, the idea behind using OSBs is that you do not need to know (or assume) the clock reference signals of your product, because the biases are computed such that consistency is assured. |
I understand that PPP positioning users do not need to know the clock reference signals after applying OSB products, but when doing clock comparison, from my point of view, the clock datum did not seem to be unified after applying the OSBs. I'd appreciate if you could clarify the logic and reasoning behind it. |
The reasoning behind it is that clocks and biases are inseparable. Imagine that the CODE and HAS clock and biases were free of any errors. Then the combined correction of clock offset and biases to the ionosphere-free observation equation would yield exactly the same values (*). If everything is done consistently in the generation of the products, this should also be the case if CODE and HAS use different clock reference signals. Hope that helps! (*) ...but potentially a common offset for all satellites still exists, which will be absorbed in the receiver clock estimate. |
Dear Dr. hirokawa,
Thank you for providing this powerful tool for SSR-PPP learners.
However, I have one question about applying ionosphere-free bias correction to clock offsets in sisre analysis code.
In general, the precise clock bias product should already be ionospheric-free.
I wonder why the parameter of osbIF and osbIF_ are used again for both precise product and SSR correction?
Also, could you please provide reference about the equation of ionospheric-free satellite clock bias correction?
I'm not sure why the code bias should be applied for satellite clock bias ionospheric correction.
Thank you very much!
Best regards.
The text was updated successfully, but these errors were encountered: