This document provides the instructions for using the Intel Ethernet Operator on supported Kubernetes clusters (Vanilla K8s or Red Hat's OpenShift Container Platform). This operator was developed with aid of the Operator SDK project.
The role of the Intel Ethernet Operator is to orchestrate and manage the configuration of the capabilities exposed by the Intel X710/E810 Series network interface cards (NICs). The operator is a state machine which will configure certain functions of the card and then monitor the status and act autonomously based on the user interaction. The operator design of the Intel Ethernet Operator supports the following X710/E810 series cards:
- Intel® Ethernet Network Adapter X710-DA2/DA4
- Intel® Ethernet Network Adapter E810-CQDA1/CQDA2
- Intel® Ethernet Network Adapter E810-XXVDA4
- Intel® Ethernet Network Adapter E810-XXVDA2
The Intel Ethernet Operator provides functionality for:
- Update of the devices' FW (Firmware) via NVM Update tool (X710/E810 NICs).
- Update of the devices' DDP (Dynamic Device Personalization) profile (E810 NICs only).
- Flow configuration of traffic handling for the devices, based on supported DDP profile (E810 NICs only).
The user interacts with the operator by providing CRs (CustomResources). The operator constantly monitors the state of the CRs to detect any changes and acts based on the changes detected. There is a separate CR to be provided for the FW/DDP update functionality and the Flow Configuration functionality. Once the CR is applied or updated, the operator/daemon checks if the configuration is already applied and if it is not, it applies the configuration.
⚠️ If you want to use Flow Configuration, dependencies (out-of-tree ICE driver, SRIOV Network Operator, Hugepages) must be fullfilled before the deployment of this operator - these dependencies are listed in the prerequisites section. If you want to use Operator only for modyfing firmware and DDP, configuration of some of the mentioned dependencies might be skipped. All the required steps are outlined in deployment section.
The controller manager pod is the first pod of the operator, it is responsible for deployment of other assets, exposing the APIs, handling of the CRs and executing the validation webhook. It contains the logic for accepting and splitting the FW/DDP CRs into node CRs and reconciling the status of each CR.
The validation webhook of the controller manager is responsible for checking each CR for invalid arguments.
The CVL-discovery pod is a DaemonSet deployed on each node in the cluster. It's responsibility is to check if a supported hardware is discovered on the platform and label the node accordingly.
To get all the nodes containing the supported devices run:
$ kubectl get EthernetNodeConfig -A
NAMESPACE NAME UPDATE
intel-ethernet-operator worker-1 InProgress
intel-ethernet-operator worker-2 InProgress
To get the list of supported devices to be found by the discovery pod run:
$ kubectl describe configmap supported-cvl-devices -n intel-ethernet-operator
The FW/DDP daemon pod is a DaemonSet deployed as part of the operator. It is deployed on each node labeled with
appropriate label indicating that a supported X710/E810 Series NIC is detected on the platform. It is a reconcile loop
which monitors the changes in each node's EthernetNodeConfig
and acts on the changes. The logic implemented into
this Daemon takes care of updating the NICs firmware and DDP profile. It is also responsible for draining the nodes,
taking them out of commission and rebooting when required by the update.
Once the operator/daemon detects a change to a CR related to the update of the Intel® X710/E810 NIC firmware, it tries to
perform an update. The firmware for the Intel® X710/E810 NICs is expected to be provided by the user in form of a tar.gz
file. The user is also responsible to verify that the firmware version is compatible with the device. The user is
required to place the firmware on an accessible HTTP server and provide an URL for it in the CR. If the file is provided
correctly and the firmware is to be updated, the Ethernet Configuration Daemon will update the Intel® X710/E810 NICs with the
NVM utility provided.
To update the NVM firmware of the Intel® X710/E810 NICs user must create a CR containing the information about which card should be programmed. The Physical Functions of the NICs will be updated in logical pairs. The user needs to provide the FW URL and checksum (SHA-1) in the CR.
For a sample CR go to Updating Firmware.
Once the operator/daemon detects a change to a CR related to the update of the Intel® E810 DDP profile, it tries to perform an update. The DDP profile for the Intel® E810 NICs is expected to be provided by the user. The user is also responsible to verify that the DDP version is compatible with the device. The user is required to place the DDP package on an accessible HTTP server and provide an URL for it in the CR. If the file is provided correctly and the DDP is to be updated, the Ethernet Configuration Daemon will update the DDP profile of Intel® E810 NICs by placing it in correct filesystem on the host.
To update the DDP profile of the Intel® E810 NIC user must create a CR containing the information about which card should be programmed. All the Physical Functions of the NICs will be updated for each NIC.
For a sample CR go to Updating DDP.
The Flow Configuration pod is a DaemonSet deployed with a CRD FlowConfigNodeAgentDeployment
provided by Ethernet
operator once it is up and running and the required DCF VF pools and their network attachment definitions are
created with SRIOV Network Operator APIs. It is deployed on each node that exposes DCF VF pool as extended node
resource. It is a reconcile loop which monitors the changes in each node's CR and acts on the changes. The logic
implemented into this Daemon takes care of updating the NIC's traffic flow configuration. It consists of two
components Flow Config controller container and UFT container.
The Node Flow Configuration Controller watches for flow rules changes via a node specific CRD - NodeFlowConfig
named
same as the node name. Once the operator/daemon detects a change to this CR related to the Intel® E810 Flow
Configuration, it tries to create/delete rules via UFT over an internal gPRC API call.
Once the Flow Config change is required the Flow Config Controller will communicate with the UFT container running a DPDK DCF application. The UFT application accepts an input with the configuration and programmes the device using a trusted VF created for this device (it is responsibility of the user to provide the trusted VF as an allocatable K8s resource - see prerequisites section).
Take note that for DDP profile update to take effect, ICE driver needs to be reloaded after reboot. Reboot is performed
by operator after updating DDP profile to one requested in EthernetClusterConfig
, but reloading of ICE driver is
responsibility of user.
Such reload can be achieved by creating systemd service that executes reload script on boot.
[Unit]
Description=ice driver reload
# Start after the network is up
Wants=network-online.target
After=network-online.target
# Also after docker.service (no effect on systems without docker)
After=docker.service
# Before kubelet.service (no effect on systems without kubernetes)
Before=kubelet.service
[Service]
Type=oneshot
TimeoutStartSec=25m
RemainAfterExit=true
ExecStart=/usr/bin/sh <path to reload script>
StandardOutput=journal+console
[Install]
WantedBy=default.target
If working on OCP, a sample MachineConfig can be used.
Some orchestration platforms based on kubernetes have /lib/firmware directory immutable. Intel Ethernet Operator needs
read and write permissions in this directory to perform FW and DDP updates. Solution to this problem is
alternative firmware search path.
Custom firmware path needs be set up on all nodes in the cluster. Controller manager pod checks content of
/sys/module/firmware_class/parameters/path
on node, on which it was deployed and takes that path into consideration
while managing rest of the operator resources.
One of the orchestration platform with /lib/firmware directory immutable is RedHat OpenShift Container Platform. To
enable FW and DDP configuration on OCP, MachineConfig
that sets firmware_class.path
kernel argument to a directory
with read
and write
permisisons must be used. User might make use of example
MachineConfig provided in this repository.
In order for the Flow Configuration to be possible, the platform needs to provide an OOT ICE driver v1.9.11. This is required since current implementations of in-tree drivers do not support all required features. It is a responsibility of the cluster admin to provide and install this driver and it is out of scope of this Operator at this time. This particular version of the driver is required, as Intel Ethernet Operator currently only supports DPDK v22.07. Kernel driver, DDP and firmware matching list can be found here.
Firmware and DDP configuration is possible with most of the in-tree drivers included in popular Linux distributions. List of supported distributions is described in Feature Support Matrix (Chapter 2.0 - Operating Systems Supported).
In order for the Flow Configuration feature to be able to configure the flow configuration of the NICs traffic the
configuration must happen using a trusted Virtual Function (VF) from each Physical Function (PF) in the NIC. Usually
it is the VF0 of a PF that has the trust mode set to on
and bound to vfio-pci
driver. This VF pool needs to be
created by the user and be allocatable as a K8s resource. This VF pool will be used exclusively by the UFT container
and no application container.
For user applications additional VF pools should be created separately as needed.
One way of creating and providing this trusted VF and application VFs is to configure it through SRIOV Network Operator. The configuration and creation of the trusted VF and application VFs is out of scope of Intel Ethernet Operator and is user responsibility.
In order to use SRIOV functionality of E810 series cards be sure that IOMMU is enabled on nodes. Enabling it usually consists of making changes in UEFI/BIOS.
In order for the Flow Configuration to work, Hugepages needs to be configured on node on which flow rules will be applied. This is standard requirement for any application that uses DPDK. Responsibilty for provisioning Hugepages lies on the user. For more information, see DPDK system requirements (2.3.2. Use of Hugepages in the Linux Environment) and Hugepages in Kubernetes.
There are multiple ways to deploy Intel Ethernet Operator.
- Build Operator images from source code and then use Operator Lifecycle Manager (OLM) or Helm to deploy Operator into cluster.
- If working on OCP, RedHat Certified release might be used. Be informed, that certified variant follows different release cycle and Flow Configuration is not supported. Refer to release notes for more information.
- If working on standard Kubernetes cluster, OperatorHub release might be used. Be informed that OperatorHub variant also follows different release cycle and Flow Configuration is not supported. Refer to release notes for more information.
⚠️ No matter which deployment variant is selected by the user, prerequisites adequate to expected functionality must be fullfilled. Based on selected variant, please follow one of the deployment steps from list below.
- Deploy from source code on OCP
- Deploy from source code on K8s
- Deploy from Certified Operators Catalog on OCP
- Deploy from OperatorHub Catalog on K8s
Once the operator is successfully deployed, the user interacts with it by creating CRs which will be interpreted by the operator.
Note: Example code below uses kubectl
and the client binary. You can substitute kubectl
with oc
if you are
operating in a OCP cluster.
If cluster is running in disconnected environment, then user has to create local cache (e.g webserver) which will serve required files. Cache should be created on machine with access to Internet. Start by creating dedicated folder for webserver.
$ mkdir webserver
$ cd webserver
Create nginx Dockerfile.
$ echo "
FROM nginx
COPY files /usr/share/nginx/html
" >> Dockerfile
Create files
folder.
$ mkdir files
$ cd files
Download required packages into files
directory.
$ curl -OjL https://downloadmirror.intel.com/769278/E810_NVMUpdatePackage_v4_20_Linux.tar.gz
Build image with packages.
$ cd ..
$ podman build -t webserver:1.0.0 .
Push image to registry that is available in disconnected environment (or copy binary image to machine via USB flash
driver by using podman save
and podman load
commands).
$ podman push localhost/webserver:1.0.0 $IMAGE_REGISTRY/webserver:1.0.0
Create Deployment on cluster that will expose packages.
apiVersion: apps/v1
kind: Deployment
metadata:
name: ice-cache
namespace: default
spec:
selector:
matchLabels:
run: ice-cache
replicas: 1
template:
metadata:
labels:
run: ice-cache
spec:
containers:
- name: ice-cache
image: $IMAGE_REGISTRY/webserver:1.0.0
ports:
- containerPort: 80
And Service to make it accessible within cluster.
apiVersion: v1
kind: Service
metadata:
name: ice-cache
namespace: default
labels:
run: ice-cache
spec:
ports:
- port: 80
protocol: TCP
selector:
run: ice-cache
After that package will be available in cluster under following path: (http://ice-cache.default.svc.cluster.local/E810_NVMUpdatePackage_v4_20_Linux.tar.gz)
To update FW on FVL/CVL(X710/E810) card or DDP on CVL(E810) card, you have to download corresponding packages for them. For security reasons, you might want to validate certificate that is exposed by server before downloading and this optional step describes how to add trusted certificate.
If operator is already installed, you can apply new configuration by manually restarting fwddp-daemon
pods.
Prepare trusted X509 certificate certificate.der
that will be added to trusted store. It could be either root CA
certificate or intermediate certificate. It must contain Subject Alternative Name
or IPAdresses
identical to path
from which packages will be downloaded.
$ kubectl create -n intel-ethernet-operator secret generic tls-cert --from-file=tls.crt=certificate.der
Restart fwddp-daemon
pods or install/reinstall operator.
Check that certificate is correctly loaded in fwddp-daemon
pods.
$ kubectl logs -n intel-ethernet-operator pod/fwddp-daemon|grep -i "found certificate - using HTTPS client"
{"level":"info","logger":"daemon","msg": "found certificate - using HTTPS client"}
To find the NIC devices belonging to the Intel® X710/E810 NIC, run following command. You can detect devices information of the NICs from the output:
$ kubectl get enc -n intel-ethernet-operator <nodename> -o jsonpath={.status} | jq
To update the Firmware of the supported device run following steps:
- If
deviceSelector
is left empty, theEthernetClusterConfig
will target all compatible devices on node specified innodeSelector
. - If
nodeSelector
is left empty, theEthernetClusterConfig
will target devices with PCI address specified indeviceSelector
on all available nodes. - If
nodeSelector
anddeviceSelector
are both left empty, theEthernetClusterConfig
will target all compatible devices on all available nodes. retryOnFail
field defaults to false. If you want update to retry 5 minutes after it encounters a failure, please set it to true.fwUpdateParam
field is optional and can be omitted in CR if not used.
⚠️ If X710/E810 NIC that you are targetting for an update has more than one device, note that Firmware for X710/E810 cards and DDP version for E810 cards is NIC wide. This means that if you setdeviceSelector
to PCI address of one of the NIC's device, Firmware and/or DDP version will be applied to all devices on that NIC.
Create a CR yaml
file:
apiVersion: ethernet.intel.com/v1
kind: EthernetClusterConfig
metadata:
name: config
namespace: <namespace>
spec:
retryOnFail: false
nodeSelectors:
kubernetes.io/hostname: <hostname>
deviceSelector: # Use cases:
deviceIds: # If you want to target specific cards on your node, use pciAddresses list.
- "<deviceID>" # If you want to target all E810 devices on your node, you might want to use deviceIDs list.
- "<deviceID>" # Also check list of notes above to create ECC that is matching your needs.
pciAddresses:
- "<pci-address>"
- "<pci-address>"
deviceConfig:
fwURL: "<URL_to_firmware>"
fwChecksum: "<file_checksum_SHA-1_hash>"
fwUpdateParam: "<optional_param>"
If fwUrl
points to external location, then depending on the environment, proxy configuration might be required. Steps
describing how to configure proxy in Operator are present in deployment guides.
The CR can be applied by running:
$ kubectl apply -f <filename>
The firmware update status can be checked by running:
$ kubectl get -n intel-ethernet-operator enc <nodename> -o jsonpath={.status.conditions} | jq
[
{
"lastTransitionTime": "2021-12-17T15:25:32Z",
"message": "Updated successfully",
"observedGeneration": 3,
"reason": "Succeeded",
"status": "True",
"type": "Updated"
}
]
The user can observe the change of the NICs firmware:
$ kubectl get -n intel-ethernet-operator enc <nodename> -o jsonpath={.status.devices[<index _of_device>].firmware} | jq
{
"MAC": "40:a6:b7:67:1f:c0",
"version": "3.00 0x80008271 1.2992.0"
}
To update the DDP profile of the supported device run following steps:
- If
deviceSelector
is left empty, theEthernetClusterConfig
will target all compatible devices on node specified innodeSelector
. - If
nodeSelector
is left empty, theEthernetClusterConfig
will target devices with PCI address specified indeviceSelector
on all available nodes. - If
nodeSelector
anddeviceSelector
are both left empty, theEthernetClusterConfig
will target all compatible devices on all available nodes. retryOnFail
field defaults to false. If you want update to retry 5 minutes after it encounters a failure, please set it to true.
⚠️ If X710/E810 NIC that you are targetting for an update has more than one device, note that Firmware for X710/E810 cards and DDP version for E810 cards is NIC wide. This means that if you setdeviceSelector
to PCI address of one of the NIC's device, Firmware and/or DDP version will be applied to all devices on that NIC.
Create a CR yaml
file:
apiVersion: ethernet.intel.com/v1
kind: EthernetClusterConfig
metadata:
name: <name>
namespace: <namespace>
spec:
retryOnFail: false
nodeSelectors:
kubernetes.io/hostname: <hostname>
deviceSelector: # Use cases:
deviceIds: # If you want to target specific cards on your node, use pciAddresses list.
- "<deviceID>" # If you want to target all E810 devices on your node, you might want to use deviceIDs list.
- "<deviceID>" # Also check list of notes above to create ECC that is matching your needs.
pciAddresses:
- "<pci-address>"
- "<pci-address>"
deviceConfig:
ddpURL: "<URL_to_DDP>"
ddpChecksum: "<file_checksum_SHA-1_hash>"
If ddpUrl
points to external location, then depending on the environment, proxy configuration might be required. Steps
describing how to configure proxy in Operator are present in deployment guides.
The CR can be applied by running:
$ kubectl apply -f <filename>
Once the DDP profile update is complete, the following status is reported:
$ kubectl get -n intel-ethernet-operator enc <nodename> -o jsonpath={.status.conditions} | jq
[
{
"lastTransitionTime": "2021-12-17T15:25:32Z",
"message": "Updated successfully",
"observedGeneration": 3,
"reason": "Succeeded",
"status": "True",
"type": "Updated"
}
]
The user can observe the change of the NICs DDP:
$ kubectl get -n intel-ethernet-operator enc <nodename> -o jsonpath={.status.devices[<index _of_device>].DDP} | jq
{
"packageName": "ICE COMMS Package",
"trackId": "0xc0000002",
"version": "1.3.30.0"
}
If using recent versions of OCP, there is an option to switch DDP profile to one already located on node. These are provided and verified by Red Hat. In order to do so, first check if profiles were discovered properly.
$ oc get enc -n intel-ethernet-operator enc <nodename> -o jsonpath={.status.discoveredDDPs} | jq
[
"/host/discover-ddp/ddp/ice-1.3.30.0.pkg.xz",
"/host/discover-ddp/ddp-comms/ice_comms-1.3.31.0.pkg.xz",
"/host/discover-ddp/ddp-wireless_edge/ice_wireless_edge-1.3.7.0.pkg.xz"
]
Create EthernetClusterConfig
CR file and provide one of selected paths:
apiVersion: ethernet.intel.com/v1
kind: EthernetClusterConfig
metadata:
name: <name>
namespace: <namespace>
spec:
nodeSelectors:
kubernetes.io/hostname: <hostname>
deviceSelector: # Use cases:
deviceIds: # If you want to target specific cards on your node, use pciAddresses list.
- "<deviceID>" # If you want to target all E810 devices on your node, you might want to use deviceIDs list.
- "<deviceID>" # Also check list of notes above to create ECC that is matching your needs.
pciAddresses:
- "<pci-address>"
- "<pci-address>"
deviceConfig:
discoveredDDPPath: "/host/discover-ddp/ddp-comms/ice_comms-1.3.31.0.pkg.xz"
$ kubectl apply -f <filename>
Once the DDP profile update is complete, the following status is reported:
$ kubectl get -n intel-ethernet-operator enc <nodename> -o jsonpath={.status.conditions} | jq
[
{
"lastTransitionTime": "2024-01-31T11:49:27Z",
"message": "Updated successfully",
"observedGeneration": 2,
"reason": "Succeeded",
"status": "True",
"type": "Updated"
}
]
The user can observe the change of the NICs DDP:
$ kubectl get -n intel-ethernet-operator enc <nodename> -o jsonpath={.status.devices[<index _of_device>].DDP} | jq
{
"packageName": "ICE COMMS Package",
"trackId": "0xc0000002",
"version": "1.3.31.0"
}
You can also update Firmware and DDP using one EthernetClusterConfig
CR. Rules are the same as for
Firmware and DDP updates.
Create a CR yaml
file:
apiVersion: ethernet.intel.com/v1
kind: EthernetClusterConfig
metadata:
name: <name>
namespace: <namespace>
spec:
nodeSelectors:
kubernetes.io/hostname: <hostname>
deviceSelector: # Use cases:
deviceIds: # If you want to target specific cards on your node, use pciAddresses list.
- "<deviceID>" # If you want to target all E810 devices on your node, you might want to use deviceIDs list.
- "<deviceID>" # Also check list of notes above to create ECC that is matching your needs.
pciAddresses:
- "<pci-address>"
- "<pci-address>"
deviceConfig:
ddpURL: "<URL_to_DDP>"
ddpChecksum: "<file_checksum_SHA-1_hash>"
fwURL: "<URL_to_firmware>"
fwChecksum: "<file_checksum_SHA-1_hash>"
If fwURL
or ddpUrl
points to external location, then depending on the environment, proxy configuration might be
required. Steps describing how to configure proxy in Operator are present in
deployment guides.
The CR can be applied by running:
$ kubectl apply -f <filename>
Once the Firmware version and DDP profile update is complete, the following status is reported:
$ kubectl get -n intel-ethernet-operator enc <nodename> -o jsonpath={.status.conditions} | jq
[
{
"lastTransitionTime": "2024-12-12T12:36:36Z",
"message": "Updated successfully",
"observedGeneration": 3,
"reason": "Succeeded",
"status": "True",
"type": "Updated"
}
]
The user can observe the change of the NICs status:
`$ kubectl get -n intel-ethernet-operator enc <nodename> -o jsonpath='{.status.devices[<index _of_device>]}' | jq
{
"DDP": {
"packageName": "ICE COMMS Package",
"trackId": "0xc0000002",
"version": "1.3.37.0"
},
...
"firmware": {
"MAC": "b4:96:91:af:6e:14",
"version": "4.01 0x800135ed 1.3256.0"
},
...
}
The Flow Configuration Agent Pod runs Unified Flow Tool (UFT) to configure Flow rules for a PF. UFT requires that trust
mode is enabled for the first VF (VF0) of a PF so that it has the capability of creating/modifying flow rules for that
PF. This VF also needs to be bound to vfio-pci
driver. The SRIOV VFs pools are K8s extended resources that are exposed
via SRIOV Network Operator.
The VF pool consists of VF0 from all available Intel E810 series NICs PF which, in this context, we call the Admin VF pool. The Admin VF pool is associated with a NetworkAttachmentDefinition that enables these VFs trust mode 'on'. The SRIOV Network Operator can be used to create the Admin VF pool and the NetworkAttachmentDefinition needed by UFT. You can find more information on creating VFs pools with SRIOV Network Operator here and creating NetworkAttachmentDefinition here. This documentation is valid for both OCP and K8s versions of SRIOV Network Operator.
The following steps will guide you through how to create the Admin VF pool and the NetworkAttachmentDefinition needed for Flow Configuration Agent Pod.
Once SRIOV Network operator is up and running we can examine the SriovNetworkNodeStates
to view available Intel E810
Series NICs as shown below:
$ kubectl get sriovnetworknodestates -n intel-ethernet-operator
NAME AGE
worker-01 1d
$ kubectl describe sriovnetworknodestates worker-01 -n intel-ethernet-operator
Name: worker-01
Namespace: intel-ethernet-operator
Labels: <none>
Annotations: <none>
API Version: sriovnetwork.openshift.io/v1
Kind: SriovNetworkNodeState
Metadata:
Spec:
Dp Config Version: 42872603
Status:
Interfaces:
Device ID: 165f
Driver: tg3
Link Speed: 100 Mb/s
Link Type: ETH
Mac: b0:7b:25:de:3f:be
Mtu: 1500
Name: eno8303
Pci Address: 0000:04:00.0
Vendor: 14e4
Device ID: 165f
Driver: tg3
Link Speed: -1 Mb/s
Link Type: ETH
Mac: b0:7b:25:de:3f:bf
Mtu: 1500
Name: eno8403
Pci Address: 0000:04:00.1
Vendor: 14e4
Device ID: 159b
Driver: ice
Link Speed: -1 Mb/s
Link Type: ETH
Mac: b4:96:91:cd:de:38
Mtu: 1500
Name: eno12399
Pci Address: 0000:31:00.0
Vendor: 8086
Device ID: 159b
Driver: ice
Link Speed: -1 Mb/s
Link Type: ETH
Mac: b4:96:91:cd:de:39
Mtu: 1500
Name: eno12409
Pci Address: 0000:31:00.1
Vendor: 8086
Device ID: 1592
Driver: ice
E Switch Mode: legacy
Link Speed: -1 Mb/s
Link Type: ETH
Mac: b4:96:91:aa:d8:40
Mtu: 1500
Name: ens1f0
Pci Address: 0000:18:00.0
Totalvfs: 128
Vendor: 8086
Device ID: 1592
Driver: ice
E Switch Mode: legacy
Link Speed: -1 Mb/s
Link Type: ETH
Mac: b4:96:91:aa:d8:41
Mtu: 1500
Name: ens1f1
Pci Address: 0000:18:00.1
Totalvfs: 128
Vendor: 8086
Sync Status: Succeeded
Events: <none>
By looking at the SriovNetworkNodeStates
status we can find the NICs information such as PCI addresses and Interface
names. Those will be used to define SriovNetworkNodePolicy
required VFs pools.
For example, the following three SriovNetworkNodePolicy
CRs will create a trusted VF pool name with resourceName
cvl_uft_admin
along with two additional VFs pools for application.
Please note, that the
SriovNetworkNodePolicy
nameduft-admin-policy
below usespfNames:
with VF index range selectors to target VF0 only of Intel E810 series NIC. More information on using VF partitioning can be found here.Also note, that the
nodeSelector
label can be modified to match your preferences.ethernet.intel.com/intel-ethernet-cvl-present
label is automatically created by Operator on nodes with E810 NICs present. You can also use labels created by solutions like Node Feature Discovery.
Save the yaml shown below to a file named sriov-network-policy.yaml
and then apply to create the VFs pools.
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
name: uft-admin-policy
namespace: sriov-network-operator
spec:
deviceType: vfio-pci
nicSelector:
pfNames:
- ens1f0#0-0
- ens1f1#0-0
vendor: "8086"
nodeSelector:
ethernet.intel.com/intel-ethernet-cvl-present: ""
numVfs: 8
priority: 99
resourceName: cvl_uft_admin
---
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
name: cvl-vfio-policy
namespace: sriov-network-operator
spec:
deviceType: vfio-pci
nicSelector:
pfNames:
- ens1f0#1-3
- ens1f1#1-3
vendor: "8086"
nodeSelector:
ethernet.intel.com/intel-ethernet-cvl-present: ""
numVfs: 8
priority: 89
resourceName: cvl_vfio
---
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetworkNodePolicy
metadata:
name: cvl-iavf-policy
namespace: sriov-network-operator
spec:
deviceType: netdevice
nicSelector:
pfNames:
- ens1f0#4-7
- ens1f1#4-7
vendor: "8086"
nodeSelector:
ethernet.intel.com/intel-ethernet-cvl-present: ""
numVfs: 8
priority: 79
resourceName: cvl_iavf
$ kubectl create -f sriov-network-policy.yaml
Check the node status to confirm that cvl_uft_admin
resource pool registered DCF capable VFs on the node.
$ kubectl describe node worker-01 -n intel-ethernet-operator | grep -i allocatable -A 20
Allocatable:
bridge.network.kubevirt.io/cni-podman0: 1k
cpu: 108
devices.kubevirt.io/kvm: 1k
devices.kubevirt.io/tun: 1k
devices.kubevirt.io/vhost-net: 1k
ephemeral-storage: 468315972Ki
hugepages-1Gi: 0
hugepages-2Mi: 8Gi
memory: 518146752Ki
openshift.io/cvl_iavf: 8
openshift.io/cvl_uft_admin: 2
openshift.io/cvl_vfio: 6
pods: 250
Next, we will need to create SRIOV network attachment definition for the DCF VF pool as shown below:
$ cat <<EOF | kubectl apply -f -
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetwork
metadata:
name: sriov-cvl-dcf
namespace: sriov-network-operator
spec:
trust: 'on'
networkNamespace: intel-ethernet-operator
resourceName: cvl_uft_admin
EOF
Note: If the above does not successfully set trust mode to 'on' for VF0, you can do it manually using this command:
$ ip link set <PF_NAME> vf 0 trust on
$ export IMAGE_REGISTRY=<OCP Image registry>
$ git clone https://github.com/intel/UFT.git
$ git checkout v22.07
$ make dcf-image
$ docker tag uft:v22.07 $IMAGE_REGISTRY/uft:v22.07
$ docker push $IMAGE_REGISTRY/uft:v22.07
⚠️ If you are using a version of sriov-network-device-plugin newer than v3.5.1, you will need to apply the "patches/uft-fix.patch
" file from the IEO repository on "images/entrypoint.sh
" located in the UFT repository before building the UFT image (runningmake dcf-image
).
$ patch -u <UFT_repo>/images/entrypoint.sh < <IEO_repo>/patches/uft-fix.patch
Note: The Admin VF pool prefix in
DCFVfPoolName
should match how it is shown on node description in Checking node status section.
apiVersion: flowconfig.intel.com/v1
kind: FlowConfigNodeAgentDeployment
metadata:
labels:
control-plane: flowconfig-daemon
name: flowconfig-daemon-deployment
namespace: intel-ethernet-operator
spec:
DCFVfPoolName: openshift.io/cvl_uft_admin
NADAnnotation: sriov-cvl-dcf
$ kubectl get pods -n intel-ethernet-operator
NAME READY STATUS RESTARTS AGE
cvl-discovery-kwjkb 1/1 Running 0 44h
cvl-discovery-tpqzb 1/1 Running 0 44h
flowconfig-daemon-worker-01 2/2 Running 0 44h
fwddp-daemon-m8d4w 1/1 Running 0 44h
intel-ethernet-operator-controller-manager-79c4d5bf6d-bjlr5 1/1 Running 0 44h
intel-ethernet-operator-controller-manager-79c4d5bf6d-txj5q 1/1 Running 0 44h
$ kubectl logs -n intel-ethernet-operator flowconfig-daemon-worker-01 -c uft
Generating server_conf.yaml file...
Done!
server :
ld_lib : "/usr/local/lib64"
ports_info :
- pci : "0000:18:01.0"
mode : dcf
do eal init ...
[{'pci': '0000:18:01.0', 'mode': 'dcf'}]
[{'pci': '0000:18:01.0', 'mode': 'dcf'}]
the dcf cmd line is: a.out -c 0x30 -n 4 -a 0000:18:01.0,cap=dcf -d /usr/local/lib64 --file-prefix=dcf --
EAL: Detected 96 lcore(s)
EAL: Detected 2 NUMA nodes
EAL: Detected shared linkage of DPDK
EAL: Multi-process socket /var/run/dpdk/dcf/mp_socket
EAL: Selected IOVA mode 'VA'
EAL: No available 1048576 kB hugepages reported
EAL: VFIO support initialized
EAL: Using IOMMU type 1 (Type 1)
EAL: Probe PCI driver: net_iavf (8086:1889) device: 0000:18:01.0 (socket 0)
EAL: Releasing PCI mapped resource for 0000:18:01.0
EAL: Calling pci_unmap_resource for 0000:18:01.0 at 0x2101000000
EAL: Calling pci_unmap_resource for 0000:18:01.0 at 0x2101020000
EAL: Using IOMMU type 1 (Type 1)
EAL: Probe PCI driver: net_ice_dcf (8086:1889) device: 0000:18:01.0 (socket 0)
ice_load_pkg_type(): Active package is: 1.3.30.0, ICE COMMS Package (double VLAN mode)
TELEMETRY: No legacy callbacks, legacy socket not created
grpc server start ...
now in server cycle
With trusted VFs and application VFs ready to be configured, create a sample ClusterFlowConfig
CR:
Please see the ClusterFlowConfig Spec for detailed specification of supported
rules. Also, please note that this ClusterFlowConfig
CR will create NodeFlowConfig
with rules on nodes, on which
pods matching podSelector
will be present.
Note: By default, first additional network interface added to pod from Multus will be named
net1
. That is whyspec.rules.pattern[0].action[0].conf.podInterface
field in provided example is set tonet1
.
apiVersion: flowconfig.intel.com/v1
kind: ClusterFlowConfig
metadata:
name: pppoes-sample
namespace: intel-ethernet-operator
spec:
rules:
- pattern:
- type: RTE_FLOW_ITEM_TYPE_ETH
- type: RTE_FLOW_ITEM_TYPE_IPV4
spec:
hdr:
src_addr: 10.56.217.9
mask:
hdr:
src_addr: 255.255.255.255
- type: RTE_FLOW_ITEM_TYPE_END
action:
- type: to-pod-interface
conf:
podInterface: net1
attr:
ingress: 1
priority: 0
podSelector:
matchLabels:
app: vagf
role: controlplane
To verify if the flow rules has been applied, sample pod that meets the criteria needs to be created.
First create SRIOV pod network to which sample pod will be attached.
apiVersion: sriovnetwork.openshift.io/v1
kind: SriovNetwork
metadata:
name: sriov-podnet
namespace: sriov-network-operator
spec:
networkNamespace: intel-ethernet-operator
resourceName: cvl_iavf
ipam: |-
{
"type": "host-local",
"subnet": "10.56.217.0/24",
"rangeStart": "10.56.217.171",
"rangeEnd": "10.56.217.181",
"routes": [
{
"dst": "0.0.0.0/0"
}
],
"gateway": "10.56.217.1"
}
When SRIOV pod network is ready to be utilized by pods, create sample pod itself.
kind: Pod
apiVersion: v1
metadata:
name: example-pod
namespace: intel-ethernet-operator
labels:
app: vagf
role: controlplane
annotations:
k8s.v1.cni.cncf.io/networks: sriov-podnet
spec:
containers:
- name: appcntr
image: alpine
command:
- /bin/sh
- '-c'
- '--'
args:
- ' while true; do sleep 30; done '
resources:
limits:
openshift.io/cvl_iavf: '1'
requests:
openshift.io/cvl_iavf: '1'
imagePullPolicy: IfNotPresent
Validate that Flow Rules are applied by the controller from UFT logs.
$ kubectl logs -n intel-ethernet-operator flowconfig-daemon-worker-01 -c uft
Generating server_conf.yaml file...
Done!
server :
ld_lib : "/usr/local/lib64"
ports_info :
- pci : "0000:18:01.0"
mode : dcf
do eal init ...
[{'pci': '0000:18:01.0', 'mode': 'dcf'}]
[{'pci': '0000:18:01.0', 'mode': 'dcf'}]
the dcf cmd line is: a.out -c 0x30 -n 4 -a 0000:18:01.0,cap=dcf -d /usr/local/lib64 --file-prefix=dcf --
EAL: Detected 96 lcore(s)
EAL: Detected 2 NUMA nodes
EAL: Detected shared linkage of DPDK
EAL: Multi-process socket /var/run/dpdk/dcf/mp_socket
EAL: Selected IOVA mode 'VA'
EAL: No available 1048576 kB hugepages reported
EAL: VFIO support initialized
EAL: Using IOMMU type 1 (Type 1)
EAL: Probe PCI driver: net_iavf (8086:1889) device: 0000:18:01.0 (socket 0)
EAL: Releasing PCI mapped resource for 0000:18:01.0
EAL: Calling pci_unmap_resource for 0000:18:01.0 at 0x2101000000
EAL: Calling pci_unmap_resource for 0000:18:01.0 at 0x2101020000
EAL: Using IOMMU type 1 (Type 1)
EAL: Probe PCI driver: net_ice_dcf (8086:1889) device: 0000:18:01.0 (socket 0)
ice_load_pkg_type(): Active package is: 1.3.30.0, ICE COMMS Package (double VLAN mode)
TELEMETRY: No legacy callbacks, legacy socket not created
grpc server start ...
now in server cycle
flow.rte_flow_attr
flow.rte_flow_item
flow.rte_flow_item
flow.rte_flow_item_ipv4
flow.rte_ipv4_hdr
flow.rte_flow_item_ipv4
flow.rte_ipv4_hdr
flow.rte_flow_item
flow.rte_flow_action
flow.rte_flow_action_vf
flow.rte_flow_action
rte_flow_attr(group=0, priority=0, ingress=1, egress=0, transfer=0, reserved=0) [rte_flow_item(type_=9, spec=None, last=None, mask=None), rte_flow_item(type_=11, spec=rte_flow_item_ipv4(hdr=rte_ipv4_hdr(version_ihl=0, type_of_service=0, total_length=0, packet_id=0, fragment_offset=0, time_to_live=0, next_proto_id=0, hdr_checksum=0, src_addr=171497737, dst_addr=0)), last=None, mask=rte_flow_item_ipv4(hdr=rte_ipv4_hdr(version_ihl=0, type_of_service=0, total_length=0, packet_id=0, fragment_offset=0, time_to_live=0, next_proto_id=0, hdr_checksum=0, src_addr=4294967295, dst_addr=0))), rte_flow_item(type_=0, spec=None, last=None, mask=None)] [rte_flow_action(type_=11, conf=rte_flow_action_vf(reserved=0, original=0, id=2)), rte_flow_action(type_=0, conf=None)]
rte_flow_attr(group=0, priority=0, ingress=1, egress=0, transfer=0, reserved=0)
1
Finish ipv4: {'hdr': {'version_ihl': 0, 'type_of_service': 0, 'total_length': 0, 'packet_id': 0, 'fragment_offset': 0, 'time_to_live': 0, 'next_proto_id': 0, 'hdr_checksum': 0, 'src_addr': 165230602, 'dst_addr': 0}}
Finish ipv4: {'hdr': {'version_ihl': 0, 'type_of_service': 0, 'total_length': 0, 'packet_id': 0, 'fragment_offset': 0, 'time_to_live': 0, 'next_proto_id': 0, 'hdr_checksum': 0, 'src_addr': 4294967295, 'dst_addr': 0}}
rte_flow_action(type_=11, conf=rte_flow_action_vf(reserved=0, original=0, id=2))
rte_flow_action_vf(reserved=0, original=0, id=2)
Action vf: {'reserved': 0, 'original': 0, 'id': 2}
rte_flow_action(type_=0, conf=None)
Validate ok...
flow.rte_flow_attr
flow.rte_flow_item
flow.rte_flow_item
flow.rte_flow_item_ipv4
flow.rte_ipv4_hdr
flow.rte_flow_item_ipv4
flow.rte_ipv4_hdr
flow.rte_flow_item
flow.rte_flow_action
flow.rte_flow_action_vf
flow.rte_flow_action
rte_flow_attr(group=0, priority=0, ingress=1, egress=0, transfer=0, reserved=0) [rte_flow_item(type_=9, spec=None, last=None, mask=None), rte_flow_item(type_=11, spec=rte_flow_item_ipv4(hdr=rte_ipv4_hdr(version_ihl=0, type_of_service=0, total_length=0, packet_id=0, fragment_offset=0, time_to_live=0, next_proto_id=0, hdr_checksum=0, src_addr=171497737, dst_addr=0)), last=None, mask=rte_flow_item_ipv4(hdr=rte_ipv4_hdr(version_ihl=0, type_of_service=0, total_length=0, packet_id=0, fragment_offset=0, time_to_live=0, next_proto_id=0, hdr_checksum=0, src_addr=4294967295, dst_addr=0))), rte_flow_item(type_=0, spec=None, last=None, mask=None)] [rte_flow_action(type_=11, conf=rte_flow_action_vf(reserved=0, original=0, id=2)), rte_flow_action(type_=0, conf=None)]
rte_flow_attr(group=0, priority=0, ingress=1, egress=0, transfer=0, reserved=0)
rte_flow_attr(group=0, priority=0, ingress=1, egress=0, transfer=0, reserved=0)
1
Finish ipv4: {'hdr': {'version_ihl': 0, 'type_of_service': 0, 'total_length': 0, 'packet_id': 0, 'fragment_offset': 0, 'time_to_live': 0, 'next_proto_id': 0, 'hdr_checksum': 0, 'src_addr': 165230602, 'dst_addr': 0}}
Finish ipv4: {'hdr': {'version_ihl': 0, 'type_of_service': 0, 'total_length': 0, 'packet_id': 0, 'fragment_offset': 0, 'time_to_live': 0, 'next_proto_id': 0, 'hdr_checksum': 0, 'src_addr': 4294967295, 'dst_addr': 0}}
rte_flow_action(type_=11, conf=rte_flow_action_vf(reserved=0, original=0, id=2))
rte_flow_action_vf(reserved=0, original=0, id=2)
Action vf: {'reserved': 0, 'original': 0, 'id': 2}
rte_flow_action(type_=0, conf=None)
free attr
free item ipv4
free item ipv4
free list item
free action vf conf
free list action
Flow rule #0 created on port 0
If ClusterFlowConfig
does not satisfy your use case, you can use NodeFlowConfig
. Create a sample, node specific
NodeFlowConfig
CR with the same name as a target node. It should have empty spec:
apiVersion: flowconfig.intel.com/v1
kind: NodeFlowConfig
metadata:
name: worker-01
spec:
Check status of CR:
$ kubectl describe nodeflowconfig worker-01
Name: worker-01
Namespace: intel-ethernet-operator
Labels: <none>
Annotations: <none>
API Version: flowconfig.intel.com/v1
Kind: NodeFlowConfig
Metadata:
Status:
Port Info:
Port Id: 0
Port Mode: dcf
Port Pci: 0000:18:01.0
Events: <none>
You can see the DCF port information from NodeFlowConfig CR status for a node. These port information can be used to identify for which port on a node the Flow rules should be applied.
Please see the NodeFlowConfig Spec for detailed specification of supported rules.
You can update the NodeFlowConfig
with a sample rule for a target port as shown below:
apiVersion: flowconfig.intel.com/v1
kind: NodeFlowConfig
metadata:
name: worker-01
namespace: intel-ethernet-operator
spec:
rules:
- pattern:
- type: RTE_FLOW_ITEM_TYPE_ETH
- type: RTE_FLOW_ITEM_TYPE_IPV4
spec:
hdr:
src_addr: 10.56.217.9
mask:
hdr:
src_addr: 255.255.255.255
- type: RTE_FLOW_ITEM_TYPE_END
action:
- type: RTE_FLOW_ACTION_TYPE_DROP
- type: RTE_FLOW_ACTION_TYPE_END
portId: 0
attr:
ingress: 1
Validate that Flow Rules are applied by the controller from UFT logs.
$ kubectl logs -n intel-ethernet-operator flowconfig-daemon-worker-01 -c uft
Generating server_conf.yaml file...
Done!
server :
ld_lib : "/usr/local/lib64"
ports_info :
- pci : "0000:5e:01.0"
mode : dcf
server's pid=14
do eal init ...
[{'pci': '0000:5e:01.0', 'mode': 'dcf'}]
[{'pci': '0000:5e:01.0', 'mode': 'dcf'}]
the dcf cmd line is: a.out -v -c 0x30 -n 4 -a 0000:5e:01.0,cap=dcf -d /usr/local/lib64 --file-prefix=dcf --
EAL: Detected CPU lcores: 88
EAL: Detected NUMA nodes: 2
EAL: RTE Version: 'DPDK 22.07.0'
EAL: Detected shared linkage of DPDK
EAL: Multi-process socket /var/run/dpdk/dcf/mp_socket
EAL: Selected IOVA mode 'VA'
EAL: VFIO support initialized
EAL: Using IOMMU type 1 (Type 1)
EAL: Probe PCI driver: net_ice_dcf (8086:1889) device: 0000:5e:01.0 (socket 0)
ice_load_pkg_type(): Active package is: 1.3.37.0, ICE COMMS Package (double VLAN mode)
TELEMETRY: No legacy callbacks, legacy socket not created
grpc server start ...
now in server cycle
flow.rte_flow_attr
flow.rte_flow_item
flow.rte_flow_item
flow.rte_flow_item_ipv4
flow.rte_ipv4_hdr
flow.rte_flow_item_ipv4
flow.rte_ipv4_hdr
flow.rte_flow_item
flow.rte_flow_action
flow.rte_flow_action
rte_flow_attr(group=0, priority=0, ingress=1, egress=0, transfer=0, reserved=0) [rte_flow_item(type_=9, spec=None, last=None, mask=None), rte_flow_item(type_=11, spec=rte_flow_item_ipv4(hdr=rte_ipv4_hdr(version_ihl=0, type_of_service=0, total_length=0, packet_id=0, fragment_offset=0, time_to_live=0, next_proto_id=0, hdr_checksum=0, src_addr=171497737, dst_addr=0)), last=None, mask=rte_flow_item_ipv4(hdr=rte_ipv4_hdr(version_ihl=0, type_of_service=0, total_length=0, packet_id=0, fragment_offset=0, time_to_live=0, next_proto_id=0, hdr_checksum=0, src_addr=4294967295, dst_addr=0))), rte_flow_item(type_=0, spec=None, last=None, mask=None)] [rte_flow_action(type_=7, conf=None), rte_flow_action(type_=0, conf=None)]
rte_flow_attr(group=0, priority=0, ingress=1, egress=0, transfer=0, reserved=0)
1
Finish ipv4: {'hdr': {'version_ihl': 0, 'type_of_service': 0, 'total_length': 0, 'packet_id': 0, 'fragment_offset': 0, 'time_to_live': 0, 'next_proto_id': 0, 'hdr_checksum': 0, 'src_addr': 165230602, 'dst_addr': 0}}
Finish ipv4: {'hdr': {'version_ihl': 0, 'type_of_service': 0, 'total_length': 0, 'packet_id': 0, 'fragment_offset': 0, 'time_to_live': 0, 'next_proto_id': 0, 'hdr_checksum': 0, 'src_addr': 4294967295, 'dst_addr': 0}}
rte_flow_action(type_=7, conf=None)
rte_flow_action(type_=0, conf=None)
Validate ok...
flow.rte_flow_attr
flow.rte_flow_item
flow.rte_flow_item
flow.rte_flow_item_ipv4
flow.rte_ipv4_hdr
flow.rte_flow_item_ipv4
flow.rte_ipv4_hdr
flow.rte_flow_item
flow.rte_flow_action
flow.rte_flow_action
rte_flow_attr(group=0, priority=0, ingress=1, egress=0, transfer=0, reserved=0) [rte_flow_item(type_=9, spec=None, last=None, mask=None), rte_flow_item(type_=11, spec=rte_flow_item_ipv4(hdr=rte_ipv4_hdr(version_ihl=0, type_of_service=0, total_length=0, packet_id=0, fragment_offset=0, time_to_live=0, next_proto_id=0, hdr_checksum=0, src_addr=171497737, dst_addr=0)), last=None, mask=rte_flow_item_ipv4(hdr=rte_ipv4_hdr(version_ihl=0, type_of_service=0, total_length=0, packet_id=0, fragment_offset=0, time_to_live=0, next_proto_id=0, hdr_checksum=0, src_addr=4294967295, dst_addr=0))), rte_flow_item(type_=0, spec=None, last=None, mask=None)] [rte_flow_action(type_=7, conf=None), rte_flow_action(type_=0, conf=None)]
rte_flow_attr(group=0, priority=0, ingress=1, egress=0, transfer=0, reserved=0)
rte_flow_attr(group=0, priority=0, ingress=1, egress=0, transfer=0, reserved=0)
1
Finish ipv4: {'hdr': {'version_ihl': 0, 'type_of_service': 0, 'total_length': 0, 'packet_id': 0, 'fragment_offset': 0, 'time_to_live': 0, 'next_proto_id': 0, 'hdr_checksum': 0, 'src_addr': 165230602, 'dst_addr': 0}}
Finish ipv4: {'hdr': {'version_ihl': 0, 'type_of_service': 0, 'total_length': 0, 'packet_id': 0, 'fragment_offset': 0, 'time_to_live': 0, 'next_proto_id': 0, 'hdr_checksum': 0, 'src_addr': 4294967295, 'dst_addr': 0}}
rte_flow_action(type_=7, conf=None)
rte_flow_action(type_=0, conf=None)
free attr
free item ipv4
free item ipv4
free list item
free list action
Flow rule #0 created on port 0
Note: If you installed Operator from RedHat Certified Operators catalog or OperatorHub catalog, it means that OLM was used as deployment method.
Uninstalling of the Operator should be done by deleting OLM ClusterServiceVersion
and Subscription
CRs from
intel-ethernet-operator
namespace. In case flowconfig-daemon was deployed, FlowConfigNodeAgentDeployment
CR also
needs to be deleted prior to uninstalling of operator itself:
$ kubectl -n intel-ethernet-operator delete flowconfignodeagentdeployments flowconfig-daemon-flowconfig-daemon
To uninstall operator execute following commands:
$ CSV=$(kubectl get subscription intel-ethernet-subscription -n intel-ethernet-operator -o json | jq -r '.status.installedCSV')
$ kubectl delete subscription intel-ethernet-subscription -n intel-ethernet-operator
$ kubectl delete csv $CSV -n intel-ethernet-operator
Replace names of resources according to ones that were used. Deleting namespace without prior deleting of resources inside it can lead to namespace being stuck at termination state. To delete namespace:
$ kubectl delete ns intel-ethernet-operator
More information can be found here https://olm.operatorframework.io/docs/tasks/uninstall-operator/
If you used make helm-deploy
to deploy Operator, you can uninstall it by executing:
$ make helm-undeploy
If you used different release name or namespace, you need to execute following command:
$ helm uninstall <release-name> --namespace=<release-namespace>
Be sure to substitute <release-name
and release-namespace
with values used in deployment process.
Then you can delete Operator namespace:
$ kubectl delete ns <release-namespace>
- Intel® Ethernet Network Adapter X710-DA2
- Intel® Ethernet Network Adapter E810-XXVDA2
- 3nd Generation Intel® Xeon® processor platform
The Intel Ethernet Operator is a functional tool to manage the update of Intel® X710/E810 NICs FW and E810 NICs DDP profile, as well as the programming of the E810 NICs VFs Flow Configuration autonomously in a Cloud Native OpenShift environment based on user input. It is easy in use by providing simple steps to apply the Custom Resources to configure various aspects of the device.