Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

enable near realtime mode (feature request) #401

Open
eid0 opened this issue Jan 20, 2025 · 3 comments
Open

enable near realtime mode (feature request) #401

eid0 opened this issue Jan 20, 2025 · 3 comments

Comments

@eid0
Copy link

eid0 commented Jan 20, 2025

Issue related to

Sunsynk / mbusd Home Assistant Add-On

I ask if it's possible to add a feature to the addon timing config.
It's very usefull to have the real time consumptions when looking for failures, so in that ocassions the polling modbus times have to be the lowest possible, but it's not advisable that these values remains that way in the setup forever in order not to load the inverter, and the n the typical 30 seconds are fine.
So I ask if we can put two polling times, realtime polling, and normal polling.
And from the frontend somehow the frontend can switch that time in the addon.

@eid0 eid0 changed the title enable near realtime. enable near realtime.(feature request) Jan 20, 2025
@eid0 eid0 changed the title enable near realtime.(feature request) enable near realtime mode (feature request) Jan 20, 2025
@kellerza
Copy link
Owner

Would you want to do this for only power sensors? or voltage & current as well.

Any other that makes sense?

@eid0
Copy link
Author

eid0 commented Jan 21, 2025

I think power sensors are the most useful, and the less items we ask the modbus, the better for the realtime answer. Thanks kellerza.

@JanKraslice
Copy link

May I ask for an explanation of the times:
Example of key ´´W´´

Image

Read 5 seconds reads every 5 seconds from the inverter?
Report 30 seconds means that the value is updated for me in a readable form in the sensor or graph in the interface?
Change by means that if I change by 80 watts the Report time will be interrupted immediately?

If the answers are YES,
can I set the Report to a lower time for example every 5 seconds? and Change by to remove it completely.

Or is it already beyond what MQTT can handle and the edge is the mentioned 30 seconds?

What is the lowest possible read and report time?

Thank you
PS:
I have tested the HF-5111B serial network server and confirm that it is functional simply connectable via pymodbus and TCP connection
I have tested the USR-TCP232-304 RS485 and confirm that it is functional simply connectable via pymodbus and TCP connection

  • I can supply copies of the screens if that helps