setup
Experiment: 20190329a-5. Duration: 98.0us (100000 - 2000), for 10 repeats each 2500.0us. Fech = 64.0Msps, total of 6272.0 pts per line, Nacq = 10. Separate tx/rx, good pulser element, on target 25mm, probe: dualNDT5MHz, target = calib_block. Timestamp = 2019-03-29 21:44:48.853785
Automated image of 20190329a experiment. First position of dual SMAs - wrong position (category: graph).
FFT of the of 20190329a experiment. Separate tx/rx, good pulser element, on target 25mm (category: FFT).
Experiment: 20190329a-5 Duration: 98.0us (100000 - 2000), for 10 repeats each 2500.0us Fech = 64.0Msps, total of 6272.0 pts per line, Nacq = 10 Separate tx/rx, good pulser element, on target 25mm, probe: dualNDT5MHz, target = calib_block Timestamp = 2019-03-29 21:44:48.853785 Details of acquisition between us 0 and 90. (category: signal).
Automated image of 20190329a experiment. Good pulser element identified, tx/rx on single path (category: graph).
FFT of the of 20190329a experiment. Good pulser element identified, tx/rx on single path (category: FFT).
Experiment: 20190329a-5 Duration: 98.0us (100000 - 2000), for 10 repeats each 2500.0us Fech = 64.0Msps, total of 6272.0 pts per line, Nacq = 10 Separate tx/rx, good pulser element, on target 25mm, probe: dualNDT5MHz, target = calib_block Timestamp = 2019-03-29 21:44:48.853785 Details of acquisition between us 25 and 27. (category: graph).
Experiment: 20190329a-5 Duration: 98.0us (100000 - 2000), for 10 repeats each 2500.0us Fech = 64.0Msps, total of 6272.0 pts per line, Nacq = 10 Separate tx/rx, good pulser element, on target 25mm, probe: dualNDT5MHz, target = calib_block Timestamp = 2019-03-29 21:44:48.853785 Details of acquisition between us 15 and 18. (category: graph).
Automated image of 20190329a experiment. Good position identified for pulser, tx/rx single, shooting on 25mm target (category: graph).
FFT of the of 20190329a experiment. Good position identified for pulser, tx/rx single, shooting on 25mm target (category: FFT).
FFT of the of 20190329a experiment. First position of dual SMAs - wrong position (category: FFT).
Automated image of 20190329a experiment. Separate tx/rx, good pulser element, on target 25mm (category: graph).
FFT of the of 20190329a experiment. Separate TX/RX, no target (category: FFT).
Experiment: 20190329a-5 Duration: 98.0us (100000 - 2000), for 10 repeats each 2500.0us Fech = 64.0Msps, total of 6272.0 pts per line, Nacq = 10 Separate tx/rx, good pulser element, on target 25mm, probe: dualNDT5MHz, target = calib_block Timestamp = 2019-03-29 21:44:48.853785 Details of acquisition between us 10 and 40. (category: graph).
Experiment: 20190329a-5 Duration: 98.0us (100000 - 2000), for 10 repeats each 2500.0us Fech = 64.0Msps, total of 6272.0 pts per line, Nacq = 10 Separate tx/rx, good pulser element, on target 25mm, probe: dualNDT5MHz, target = calib_block Timestamp = 2019-03-29 21:44:48.853785 Details of Hilbert acquisition between us 32.2 and 33. (category: hilbert,signal).
Automated image of 20190329a experiment. Separate TX/RX, no target (category: graph).