This repository has been archived by the owner. It is now read-only.
-
Notifications
You must be signed in to change notification settings - Fork 39
/
Copy pathCTRON-CHASSIS-MIB
247 lines (209 loc) · 8.77 KB
/
CTRON-CHASSIS-MIB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
CTRON-CHASSIS-MIB DEFINITIONS ::= BEGIN
-- ################################
-- ctenvir-mib.txt
-- ################################
-- Revision: 1.05.01
-- Part Number: 2170553
-- Date: May 23, 1997
-- Cabletron Systems, Inc.
-- 35 Industrial Way, P.O. Box 5005
-- Rochester, NH 03867-0505
-- (603) 332-9400
-- This module provides authoritative definitions for Cabletron's
-- enterprise-specific chassis MIB.
--
-- This module will be extended, as required.
--
-- Cabletron Systems reserves the right to make changes in
-- specification and other information contained in this document
-- without prior notice. The reader should consult Cabletron Systems
-- to determine whether any such changes have been made.
--
-- In no event shall Cabletron Systems be liable for any incidental,
-- indirect, special, or consequential damages whatsoever (including
-- but not limited to lost profits) arising out of or related to this
-- document or the information contained in it, even if Cabletron
-- Systems has been advised of, known, or should have known, the
-- possibility of such damages.
--
-- Cabletron grants vendors, end-users, and other interested parties
-- a non-exclusive license to use this Specification in connection
-- with the management of Cabletron products.
-- Copyright October 95 Cabletron Systems
-- This mib contains objects that are an extenstion to the
-- standard chassis MIB.
IMPORTS
ctronChassis FROM CTRON-MIB-NAMES
OBJECT-TYPE FROM RFC-1212;
-- chassis group. Implementation of this group is mandatory.
ctChas OBJECT IDENTIFIER ::= { ctronChassis 1 }
-- the environment group. Implementation of this group is
-- mandatory for power supply monitoring.
ctEnviron OBJECT IDENTIFIER ::= { ctronChassis 2 }
-- the fan module group. Implementation of this group is
-- mandatory for fan module monitoring.
ctFanModule OBJECT IDENTIFIER ::= { ctronChassis 3 }
ctChasFNB OBJECT-TYPE
SYNTAX INTEGER {
absent(1),
present(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the presence or absence of the FNB."
::= { ctChas 1 }
ctChasAlarmEna OBJECT-TYPE
SYNTAX INTEGER {
disable(1),
enable(2),
notSupported(3) -- Object is not supported
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allow an audible alarm to be either enabled or dis-
abled. Setting this object to disable(1) will prevent an
audible alarm from being heard and will also stop the
sound from a current audible alarm. Setting this object
to enable(2) will allow an audible alarm to be heard and
will also enable the sound from a current audible alarm,
if it has previously been disabled. This object will read
with the current setting."
::= { ctChas 2 }
chassisAlarmState OBJECT-TYPE
SYNTAX INTEGER {
chassisNoFaultCondition(1),
chassisFaultCondition(2),
notSupported(3) -- Object is not supported
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the current condition of the power supply
fault detection circuit. This object will read with
the value of chassisNoFaultCondition(1) when the chassis
is currently operating with no power faults detected.
This object will read with the value of
chassisFaultCondition(2) when the chassis is currently in
a power fault condition."
::= { ctChas 3 }
-- The environment group
-- Implementation of this group is mandatory for devices that
-- incorporate environmental support.
ctChasPowerTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtChasPowerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of power supply entries."
::= { ctEnviron 1 }
ctChasPowerEntry OBJECT-TYPE
SYNTAX CtChasPowerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the powerTable providing objects for a
power supply."
INDEX { ctChasPowerSupplyNum }
::= { ctChasPowerTable 1 }
CtChasPowerEntry ::=
SEQUENCE {
ctChasPowerSupplyNum
INTEGER,
ctChasPowerSupplyState
INTEGER,
ctChasPowerSupplyType
INTEGER,
ctChasPowerSupplyRedundancy
INTEGER
}
ctChasPowerSupplyNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the power supply."
::= { ctChasPowerEntry 1 }
ctChasPowerSupplyState OBJECT-TYPE
SYNTAX INTEGER {
infoNotAvailable(1),
notInstalled(2),
installedAndOperating(3),
installedAndNotOperating(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the power supply's state."
::= { ctChasPowerEntry 2 }
ctChasPowerSupplyType OBJECT-TYPE
SYNTAX INTEGER {
ac-dc(1),
dc-dc(2),
notSupported(3), -- Object is not supported
highOutput(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the power supply type."
::= { ctChasPowerEntry 3 }
ctChasPowerSupplyRedundancy OBJECT-TYPE
SYNTAX INTEGER {
redundant(1),
notRedundant(2),
notSupported(3) -- Object is not supported
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes whether or not the power supply is redundant."
::= { ctChasPowerEntry 4 }
-- The fan module group
-- Implementation of this group is mandatory for devices that
-- incorporate fan module monitoring support.
ctChasFanModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF CtChasFanModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of fan module entries."
::= { ctFanModule 1 }
ctChasFanModuleEntry OBJECT-TYPE
SYNTAX CtChasFanModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the fan module Table providing objects for a
fan module."
INDEX { ctChasFanModuleNum }
::= { ctChasFanModuleTable 1 }
CtChasFanModuleEntry ::=
SEQUENCE {
ctChasFanModuleNum
INTEGER,
ctChasFanModuleState
INTEGER
}
ctChasFanModuleNum OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the Fan module that may have failed."
::= { ctChasFanModuleEntry 1 }
ctChasFanModuleState OBJECT-TYPE
SYNTAX INTEGER {
infoNotAvailable(1),
notInstalled(2),
installedAndOperating(3),
installedAndNotOperating(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Denotes the fan modules state."
::= { ctChasFanModuleEntry 2 }
END