Notifications
You must be signed in to change notification settings - Fork 10
/
Copy pathCircuitBreakerResURI.swagger.json
129 lines (129 loc) · 4.24 KB
/
CircuitBreakerResURI.swagger.json
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
{
"swagger": "2.0",
"info": {
"title": "Circuit Breaker (IEC 61850)",
"version": "2019-06-13",
"license": {
"name": "OCF Data Model License",
"url": "https://github.com/openconnectivityfoundation/core/blob/e28a9e0a92e17042ba3e83661e4c0fbce8bdc4ba/LICENSE.md",
"x-copyright": "copyright 2019 Open Connectivity Foundation, Inc. All rights reserved."
},
"termsOfService": "https://openconnectivityfoundation.github.io/core/DISCLAIMER.md"
},
"schemes": ["http"],
"consumes": ["application/json"],
"produces": ["application/json"],
"paths": {
"/CircuitBreakerResURI" : {
"get": {
"description": "This Resource describes functions for the control and monitoring of IEC 61850 based circuit breaker.",
"parameters": [
{"$ref": "#/parameters/interface"}
],
"responses": {
"200": {
"description" : "",
"x-example":
{
"rt": ["oic.r.circuitbreaker"],
"if": ["oic.if.s", "oic.if.baseline"],
"status": "on",
"ratedcurrent": 10.0,
"ratedbreakingcurrent": 2500.0,
"ratedvoltage": 460.0,
"leakagecurrent": 0.5,
"insulationresistance": 0.3,
"timestamp": "2015-11-05T14:30:00.10Z"
},
"schema": { "$ref": "#/definitions/CircuitBreaker" }
}
}
}
}
},
"parameters": {
"interface" : {
"in": "query",
"name": "if",
"type": "string",
"enum": ["oic.if.s", "oic.if.baseline"]
}
},
"definitions": {
"CircuitBreaker" : {
"properties": {
"rt" : {
"description": "The Resource Type",
"items": {
"enum": ["oic.r.circuitbreaker"],
"maxLength": 64,
"type": "string"
},
"minItems": 1,
"uniqueItems": true,
"readOnly": true,
"type": "array"
},
"status" : {
"description": "The circuit breaker status. The status can only be reset out of bounds.",
"readOnly": true,
"type": "string",
"enum" : [ "on", "off", "trip"]
},
"ratedcurrent" : {
"description": "The rated current in Ampere, defined at manufacturing time.",
"readOnly": true,
"type": "number"
},
"ratedbreakingcurrent" : {
"description": "The rated breaking current in Ampere, defined at manufacturing time.",
"readOnly": true,
"type": "number"
},
"ratedvoltage" : {
"description": "The rated voltage in Volts, defined at manufacturing time.",
"readOnly": true,
"type": "number"
},
"leakagecurrent" : {
"description": "The leakage current in mA.",
"readOnly": true,
"type": "number"
},
"insulationresistance" : {
"description": "Insulation resistance of circuit breaker (M Ohm).",
"readOnly": true,
"type": "number"
},
"timestamp": {
"description": "An RFC3339 formatted time indicating when the data was observed (e.g.: 2016-02-15T09:19Z, 1996-12-19T16:39:57-08:00). Note that 1/100 time resolution should be used.",
"format": "date-time",
"readOnly": true,
"type": "string"
},
"n": {
"$ref": "https://openconnectivityfoundation.github.io/core/schemas/oic.common.properties.core-schema.json#/definitions/n"
},
"id": {
"$ref": "https://openconnectivityfoundation.github.io/core/schemas/oic.common.properties.core-schema.json#/definitions/id"
},
"if": {
"description": "The OCF Interface set supported by this Resource.",
"items": {
"enum": [
"oic.if.s",
"oic.if.baseline"
],
"type": "string"
},
"minItems": 2,
"uniqueItems": true,
"readOnly": true,
"type": "array"
}
},
"type": "object",
"required": ["status", "ratedcurrent", "ratedbreakingcurrent", "ratedvoltage", "timestamp"]
}
}
}