Skip to content
New issue

Have a question about this project? Sign up for a free GitHub account to open an issue and contact its maintainers and the community.

By clicking “Sign up for GitHub”, you agree to our terms of service and privacy statement. We’ll occasionally send you account related emails.

Already on GitHub? Sign in to your account

Read.spc leads to error while reading any horiba spc files From 2018 version till now #3

Open
GegznaV opened this issue Jul 10, 2021 · 0 comments

Comments

@GegznaV
Copy link
Member

GegznaV commented Jul 10, 2021

@r-hyperspec/r-hyperspec, I think that the discussion of cbeleites/hyperSpec#124 should continue here.

Some messages by @b8e5n from the original issue:


So far, I had no luck reading Horiba LabSpec generated files using any version after 2017 10 05.
The error message is the following:

Error in x[[jj]][iseq] <- vjj : replacement has length zero

Looking at the code, I haven't found anything that could fix that.


sample.spc.pdf
Here is a sample file.
Notice that I renamed it was PDF so GitHub would let me upload it.
I just tried and I cannot read it with the latest version of hyperSpec, which gives me the same issues as I have with other files. The file was generated by Horiba LabSpec 6.


More details are in discussion cbeleites/hyperSpec#124

Sign up for free to join this conversation on GitHub. Already have an account? Sign in to comment