86 changes: 49 additions & 37 deletions src/dbschema/bynar_stats.sql
Original file line number Diff line number Diff line change
Expand Up @@ -94,14 +94,17 @@ BEGIN
region_name VARCHAR (256) PRIMARY KEY NOT NULL
);

CREATE TABLE IF NOT EXISTS storage_types (
storage_id SERIAL NOT NULL UNIQUE,
storage_type VARCHAR (256) PRIMARY KEY NOT NULL
);
INSERT INTO storage_types (storage_type) vALUES ('ceph');
INSERT INTO storage_types (storage_type) vALUES ('sio');
INSERT INTO storage_types (storage_type) vALUES ('solidfire');
INSERT INTO storage_types (storage_type) VALUES ('hitachi');
IF NOT table_exists('public', 'storage_types')
THEN
CREATE TABLE storage_types (
storage_id SERIAL NOT NULL UNIQUE,
storage_type VARCHAR (256) PRIMARY KEY NOT NULL
);
INSERT INTO storage_types (storage_type) vALUES ('ceph');
INSERT INTO storage_types (storage_type) vALUES ('sio');
INSERT INTO storage_types (storage_type) vALUES ('solidfire');
INSERT INTO storage_types (storage_type) VALUES ('hitachi');
END IF;

CREATE TABLE IF NOT EXISTS storage_details (
detail_id SERIAL NOT NULL UNIQUE,
Expand All @@ -127,20 +130,23 @@ BEGIN
UNIQUE (device_path, detail_id)
);

CREATE TABLE IF NOT EXISTS operation_types (
IF NOT table_exists('public', 'operation_types')
THEN
CREATE TABLE operation_types (
type_id SERIAL NOT NULL UNIQUE,
op_name VARCHAR (128) PRIMARY KEY NOT NULL
);

INSERT INTO operation_types (op_name) VALUES ('diskadd');
INSERT INTO operation_types (op_name) VALUES ('diskreplace');
INSERT INTO operation_types (op_name) VALUES ('diskremove');
INSERT INTO operation_types (op_name) VALUES ('clusteradd');
INSERT INTO operation_types (op_name) VALUES ('clusterdelete');
INSERT INTO operation_types (op_name) VALUES ('waitingforreplacement');
-- Evaluation combines all the internal work like checking
-- file system for corruption, attempting repair etc.
INSERT INTO operation_types (op_name) VALUES ('evaluation');
INSERT INTO operation_types (op_name) VALUES ('diskadd');
INSERT INTO operation_types (op_name) VALUES ('diskreplace');
INSERT INTO operation_types (op_name) VALUES ('diskremove');
INSERT INTO operation_types (op_name) VALUES ('clusteradd');
INSERT INTO operation_types (op_name) VALUES ('clusterdelete');
INSERT INTO operation_types (op_name) VALUES ('waitingforreplacement');
-- Evaluation combines all the internal work like checking
-- file system for corruption, attempting repair etc.
INSERT INTO operation_types (op_name) VALUES ('evaluation');
END IF;

-- This table will hold one record per (device_id, entry_id)
-- Sub operations for each record here should be added to
Expand Down Expand Up @@ -182,32 +188,38 @@ BEGIN

IF (current_revision < 3)
THEN
UPDATE TABLE operation_types SET op_name='waiting_for_replacement' WHERE op_name='waitingforreplacement';
UPDATE operation_types SET op_name='waiting_for_replacement' WHERE op_name='waitingforreplacement';
END IF;

IF (current_revision < 4)
THEN
-- Captures the detail of each hardware replacement operation
-- for the server
CREATE TABLE IF NOT EXISTS hardware (
device_id SERIAL NOT NULL UNIQUE,
detail_id INTEGER REFERENCES storage_details(detail_id) ON DELETE CASCADE,
device_name VARCHAR NOT NULL,
device_location VARCHAR, --some devices have location data
state VARCHAR, -- refers to device state in the state machine
serial_number VARCHAR, -- some hardware devices have serial numbers
UNIQUE (device_name, detail_id)
);
CREATE TABLE IF NOT EXISTS hardware_types (
-- Added during redfish support which monitors different hardwares other
-- than just disks.
IF NOT table_exists('public', 'hardware_types')
THEN
CREATE TABLE hardware_types (
hardware_id SERIAL NOT NULL UNIQUE,
hardware_type VARCHAR (256) PRIMARY KEY NOT NULL
);
INSERT INTO hardware_types (hardware_type) VALUES ('array_controller');
INSERT INTO hardware_types (hardware_type) VALUES ('disk');
INSERT INTO hardware_types (hardware_type) VALUES ('fan');
INSERT INTO hardware_types (hardware_type) VALUES ('ilo_manager');
INSERT INTO hardware_types (hardware_type) VALUES ('power_supply');
INSERT INTO hardware_types (hardware_type) VALUES ('storage_controller');
INSERT INTO hardware_types (hardware_type) VALUES ('array_controller');
INSERT INTO hardware_types (hardware_type) VALUES ('disk');
INSERT INTO hardware_types (hardware_type) VALUES ('fan');
INSERT INTO hardware_types (hardware_type) VALUES ('ilo_manager');
INSERT INTO hardware_types (hardware_type) VALUES ('power_supply');
INSERT INTO hardware_types (hardware_type) VALUES ('storage_controller');
END IF;

-- Rename devices table to hardware. Add a type column to it
-- to indicate hardware_types. Make device_name and detail_id unique instead
-- of device_path. Add fields needed for other hardware.
IF table_exists('public', 'devices')
THEN
ALTER TABLE devices ADD COLUMN hardware_type INTEGER REFERENCES hardware_types(hardware_id);
ALTER TABLE devices DROP CONSTRAINT IF EXISTS devices_device_path_detail_id_key;
ALTER TABLE devices ALTER COLUMN device_path DROP NOT NULL;
ALTER TABLE devices ADD CONSTRAINT device_name_detail_id UNIQUE(device_name, detail_id);
ALTER TABLE devices RENAME TO hardware;
END IF;
END IF;