## Initial Setup

Tested with an EdgeSwitch 16 XG.
Tested with an EdgeSwitch 16 XG, configured as a L2 core/distro switch (homelab).

1. Basics (use where appropriate):
1. Log in: Username `ubnt`, password `ubnt`.
1. Enter enable mode: `en`
1. Enter config mode: `conf`
1. Exit any mode: `exit`
1. Save config: `write mem`
1. Setup enable-mode stuff:
1. Set hostname: `hostname <hostname>`
1. **TODO** Network stuff?
1. Setup VLANs:
1. Enter VLAN mode: `vlan database`
1. **TODO**
- Log in: Username `ubnt`, password `ubnt`.
- Enter enable mode (aka. privileged exec mode) from unprivileged mode: `en`
- Enter config mode from enable mode: `conf`
- Exit any mode: `exit`
- Save config: `write mem`
- Assume config commands are in config mode, unless stated otherwise.
1. Add new user and remove the default:
1. Add new user (config mode): `username <username> level 15 override-complexity-check password` (prompts for password)
1. Relog as the new user.
1. Delete the default user (config mode): `no username ubnt`
1. Setup basics:
1. Set hostname (enable mode): `hostname <hostname>`
1. Set pre-login banner: `set clibanner "Hello"`
1. Setup AAA:
1. Set timezone (Norway example):
1. `clock timezone +1`
1. `clock summer-time recurring EU`
1. **TODO**: Verify this.
1. Set SNTP server: `sntp server <server>`
1. Setup STP:
1. Set mode: `spanning-tree mode rstp`
1. Set priority: `spanning-tree mst priority 0 8192`
1. Enable STP on all ports by default: `spanning-tree port mode all` (default)
1. Enable BPDU guard on all edge ports: `spanning-tree bpduguard`
1. Setup VLANs:
1. Enter VLAN mode (enable mode): `vlan database`
1. Create VLAN (VLAN mode):
1. Define: `vlan <vid>`
1. Name: `vlan name <vid> <name>`
1. Setup management interface:
1. Set management VLAN (enable mode): `network mgmt_vlan <vid>`
1. **TODO**
1. Setup access ports (untagged edge):
1. Enter interface config: `int <range>` (e.g. `int 0/8-0/12`)
1. Description: `desc host:pve`
1. Disable flow control: `no flowcontrol` (default)
1. Configure LLDP:
1. `lldp receive` (default)
1. `lldp transmit` (default)
1. `lldp transmit-tlv port-desc`
1. `lldp transmit-tlv sys-name`
1. `lldp transmit-tlv sys-desc`
1. Configure VLAN (example: VLAN 10):
1. **TODO**
1. `switchport mode access`
1. `switchport access vlan 10`
1. `vlan acceptframe admituntaggedonly`
1. `vlan participation include 10`
1. `vlan pvid 10`
1. Configure STP:
1. Set as edge port: `spanning-tree edgeport`
1. (Optional) Enable BPDU filter: `spanning-tree bpdufilter`
1. Configure storm control:
1. `storm-control unicast level 5`
1. `storm-control broadcast level 5`
1. `storm-control multicast level 75`
1. Setup L2 link ports (trunk link):
1. Repeat relevant access port config.
1. Configure VLAN trunk (example: VLANs 10+50):
1. **TODO**
1. `switchport mode trunk`
1. `switchport trunk allowed vlan all`
1. `vlan acceptframe vlanonly`
1. `vlan participation include 10,50`
1. `vlan participation include 10,50`
1. Configure STP:
1. Enable root guard: `spanning-tree guard root`
1. Setup AAA:
1. Setup (better) local auth:
1. Remove any custom AAA commands.
1. Avoid enable password: `aaa authorization exec default local`
1. Setup console:
1. Enter line config: `line console`
1. Set timeout: `serial timeout 60` (mintes)
1. Setup SSH:
1. **TODO**
1. Set SSH timeout (enable mode): `sshcon timeout 60` (mintes)
1. **TODO** Line enable/authn/authz
1. **TODO**:
1. SNMP
1. Syslog
1. IGMP/MLD snooping.
1. MTU

## Commands

- System:
- Show hardware and versions: `show version`
- Show active and backup firmware: `show bootvar`
- L2 interfaces:
- Notice the difference between the `show interface` and `show interfaces` commands.
- Show status: `show interfaces status all`
- Show traffic counters: `show interface counters`
- Show switchport config: `show interfaces switchport [port]`
- L3 interfaces:
- Show brief: `show ip int brief`
- STP:
- Show summary: `show spanning-tree`

## Tasks

Expand All @@ -42,6 +122,12 @@ Tested with an EdgeSwitch 16 XG.

### Upgrade Software

**TODO**
1. Consider whether to use the lite version (limited to 255 VLANS for lower memory utilization).
1. Download the new version from the downloads page: `https://ui.com/download/edgemax`
1. Download the firmware to the backup partition: `copy tftp://<ip-address>/<filename> backup` (example)
1. Select the backup partition for the next boot: `boot system backup`
1. Reboot: `reload`
1. Verify that the new firmware is booted into: `show bootvar`
1. Copy the backup firmware to the active partition: `copy backup active`

{% include footer.md %}