Notifications
You must be signed in to change notification settings - Fork 33
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
Signed-off-by: Tony Xiang <[email protected]>
- Loading branch information
1 parent
a68bb7f
commit 3d5edca
Showing
7 changed files
with
76 additions
and
1 deletion.
There are no files selected for viewing
2 changes: 1 addition & 1 deletion
2
tests/data/state_estimation/leaf-without-power-sensor/params.json
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
29 changes: 29 additions & 0 deletions
29
tests/data/state_estimation/middle-without-power-sensor/input.json
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,29 @@ | ||
{ | ||
"version": "1.0", | ||
"type": "input", | ||
"is_batch": false, | ||
"attributes": {}, | ||
"data": { | ||
"node": [ | ||
{"id": 0, "u_rated": 10}, | ||
{"id": 1, "u_rated": 10}, | ||
{"id": 7, "u_rated": 10} | ||
], | ||
"line": [ | ||
{"id": 2, "from_node": 0, "to_node": 1, "from_status": 1, "to_status": 1, "r1": 1.0, "x1": 0.0, "c1": 0.0, "tan1": 0.0, "i_n": 500}, | ||
{"id": 8, "from_node": 1, "to_node": 7, "from_status": 1, "to_status": 1, "r1": 1.0, "x1": 0.0, "c1": 0.0, "tan1": 0.0, "i_n": 500} | ||
], | ||
"source": [ | ||
{"id": 3, "node": 0, "status": 1, "u_ref": 1.0} | ||
], | ||
"sym_load": [ | ||
{"id": 4, "node": 1, "status": 1, "type": 0, "p_specified": 9, "q_specified": 0} | ||
], | ||
"sym_power_sensor": [ | ||
{"id": 5, "measured_object": 3, "measured_terminal_type": 2, "power_sigma": 1, "p_measured": 10, "q_measured": 0} | ||
], | ||
"sym_voltage_sensor": [ | ||
{"id": 6, "measured_object": 0, "u_sigma": 1, "u_measured": 10} | ||
] | ||
} | ||
} |
3 changes: 3 additions & 0 deletions
3
tests/data/state_estimation/middle-without-power-sensor/input.json.license
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,3 @@ | ||
SPDX-FileCopyrightText: Contributors to the Power Grid Model project <[email protected]> | ||
|
||
SPDX-License-Identifier: MPL-2.0 |
8 changes: 8 additions & 0 deletions
8
tests/data/state_estimation/middle-without-power-sensor/params.json
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,8 @@ | ||
{ | ||
"calculation_method": ["newton_raphson", "iterative_linear"], | ||
"rtol": 1e-8, | ||
"atol": { | ||
"default": 1e-8, | ||
".+_residual": 5e-4 | ||
} | ||
} |
3 changes: 3 additions & 0 deletions
3
tests/data/state_estimation/middle-without-power-sensor/params.json.license
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,3 @@ | ||
SPDX-FileCopyrightText: Contributors to the Power Grid Model project <[email protected]> | ||
|
||
SPDX-License-Identifier: MPL-2.0 |
29 changes: 29 additions & 0 deletions
29
tests/data/state_estimation/middle-without-power-sensor/sym_output.json
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,29 @@ | ||
{ | ||
"version": "1.0", | ||
"type": "sym_output", | ||
"is_batch": false, | ||
"attributes": {}, | ||
"data": { | ||
"node": [ | ||
{"id": 0, "energized": 1, "u_pu": 1, "u": 10, "u_angle": 0}, | ||
{"id": 1, "energized": 1, "u_pu": 0.9, "u": 9, "u_angle": 0}, | ||
{"id": 7, "energized": 1, "u_pu": 0.9, "u": 9, "u_angle": 0} | ||
], | ||
"line": [ | ||
{"id": 2, "energized": 1, "p_from": 10, "q_from": 0, "p_to": -9, "q_to": 0}, | ||
{"id": 8, "energized": 1, "p_from": 0, "q_from": 0, "p_to": 0, "q_to": 0} | ||
], | ||
"source": [ | ||
{"id": 3, "energized": 1, "p": 10, "q": 0} | ||
], | ||
"sym_load": [ | ||
{"id": 4, "energized": 1, "p": 9, "q": 0} | ||
], | ||
"sym_power_sensor": [ | ||
{"id": 5, "energized": 1, "p_residual": 0, "q_residual": 0} | ||
], | ||
"sym_voltage_sensor": [ | ||
{"id": 6, "energized": 1, "u_residual": 0} | ||
] | ||
} | ||
} |
3 changes: 3 additions & 0 deletions
3
tests/data/state_estimation/middle-without-power-sensor/sym_output.json.license
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,3 @@ | ||
SPDX-FileCopyrightText: Contributors to the Power Grid Model project <[email protected]> | ||
|
||
SPDX-License-Identifier: MPL-2.0 |