Smart meter manufacturer | Model | Interface socket | Baud rate | Parity | Encryption | Physical signal interface | Known countries Note 1 |
Payload protocol | Standard | Our product |
---|---|---|---|---|---|---|---|---|---|---|
Aidon with built-in interface | 6442, 6490, 6492 | RJ11/12 | 115200 | 8N1 | No | Open collector | Sweden | P1-DSMR v5.0.2 | EN-IEC 62056-21 Mode D | Pow-P1 with RJ12 cable |
Aidon with built-in interface | 65xx, 6474, 6476, 6477, 6479, 6484 | RJ45 ("Ethernet") | 2400 | 8E1 | No | M-bus 24/12V (HAN-NVE) | Norway, Sweden | HAN-NVE (HDLC/DLMS/COSEM) | EN-IEC 62056-7-5 | Pow-U with RJ45 cable |
Aidon with Rejlers Politerm interface | 65xx, 6474, 6476, 6477, 6479, 6484 | RJ45 ("Ethernet") | 2400 | 8N1 | No | M-bus 24/12V (HAN-NVE) | Norway | HAN-NVE (HDLC/DLMS/COSEM) | EN-IEC 62056-7-5 | Pow-U with RJ45 cable |
Iskraemeco | AM550 | RJ11/12 | 115200 | 8N1 | No | Open collector | P1-DSMR v5.0.2 | EN-IEC 62056-21 Mode D | Pow-P1 with RJ12 cable | |
Iskraemeco | AM550 | RJ11/12 | 38400 | 8N1 | No | Open collector | Slovenia | P1-DSMR v5.0.2 | Special payload formats | Pow-P1 with RJ12 cable |
Kaifa/Nuri | "MA105H2E MA304H3E MA304H4 MA304T3 MA304T4" | RJ45 ("Ethernet") | 2400 | 8E1 | No | M-bus 24/12V (HAN-NVE) | Norway | HAN-NVE (HDLC/DLMS/COSEM) | EN-IEC 62056-7-5 | Pow-U with RJ45 cable |
Kaifa/Nuri | MA309M | RJ11/12 | 2400 | 8N1 | Country / Network operator dependent | M-bus 34/22V | Austria | HDLC/DLMS/COSEM | Pow-U with RJ12 cable | |
Kamstrup Omnia | Omnia E-meter | RJ11/12 | 115200 | 8N1 | No | Open collector | Denmark, Sweden | P1-DSMR v5.0.2 | EN-IEC 62056-21 Mode D | Pow-P1 with RJ12 cable |
Kamstrup Omnipower with HAN-NVE adapter | 684xx2, 684xx3, 685xx2, 685xx3, 686xx1, C65 | RJ45 ("Ethernet") | 2400 | 8N1 | Country / Network operator dependent | M-bus 24/12V (HAN-NVE) | Norway, Sweden, Denmark, Switzerland | HDLC/DLMS/COSEM | EN-IEC 62056-7-5 |
Pow-U with RJ45 cable Note 2 |
Kamstrup Omnipower with P1 adapter | 684xx2, 684xx3, 685xx2, 685xx3, 686xx1, C65 | RJ11/12 | 115200 | 8N1 | No | Open collector | Denmark, Sweden | P1-DSMR v5.0.2 | EN-IEC 62056-21 Mode D |
Pow-P1 with RJ12 cable and modification (Notify us when ordering) Note 3 |
Kamstrup Omnipower, without adapter, HAN-NVE configuration | 684xx2, 684xx3, 685xx2, 685xx3, 686xx1, C65 | 6-pin plug in expansion bay | 2400 | 8N1 | Country / Network operator dependent | TTL 3.3V | Norway, Sweden, Denmark, Switzerland | HDLC/DLMS/COSEM | EN-IEC 62056-7-5 | Pow-K |
Kamstrup Omnipower, without adapter, P1 configuration | 684xx2, 684xx3, 685xx2, 685xx3, 686xx1, C65 | 6-pin plug in expansion bay | 115200 | 8N1 | No | TTL 3.3V | Sweden, Denmark ? | P1-DSMR v5.0.2 | EN-IEC 62056-21 Mode D | Pow-K |
Landis & Gyr with Embriq Politerm800 module | E350 | RJ45 | 2400 | 8N1 | No | M-bus 24/12V (HAN-NVE) | Norway (Klive nett) | HAN-NVE (HDLC/DLMS/COSEM) | EN-IEC 62056-7-5 | Pow-U with RJ45 cable |
Landis & Gyr | E360 | RJ11/12 | 115200 | 8N1 | No | Open collector | Sweden, Denmark, | P1-DSMR v5.0.2 | EN-IEC 62056-21 Mode D | Pow-P1 with RJ12 cable |
Landis + Gyr | E450 S4, S5 | RJ11/12 | 2400 | 8E1 | Country / Network operator dependent | M-bus 34/22V | Austria, Switzerland | HDLC/DLMS/COSEM | Pow-U with RJ12 cable | |
Landis + Gyr | E450 S4, S5 | RJ11/12 | 2400 | 8N1 | Country / Network operator dependent | M-bus 24/12V | Austria: Netz Burgenland | Network operator specific (ASCII) | Pow-U with RJ12 cable | |
NES | G5 83335-X | RJ11/12 | 115200 | 8N1 | No | Open collector | Denmark | P1-DSMR v5.0.2 | EN-IEC 62056-21 Mode D | Pow-P1 with RJ12 cable |
Sagemcom | S211, T211 | RJ11/12 | 115200 | 8N1 | No | Open collector | Sweden | P1-DSMR v5.0.2 | EN-IEC 62056-21 Mode D | Pow-P1 with RJ12 cable |
Sagemcom | T210-D, S210 | RJ11/12 | 2400 | 8N1 | Country / Network operator dependent | M-bus 34/22V (Is this wrong?) | Austria | HDLC/DLMS/COSEM | Pow-U with RJ12 cable | |
Sanxing | S34U18 | RJ11/12 | 115200 | 8N1 | No | Open collector | Sweden | P1-DSMR v5.0.2 | EN-IEC 62056-21 Mode D | Pow-P1 with RJ12 cable |
Sanxing | S34U18 | RJ11/12 | 115200 | 8N1 | No | Open collector | Hungary | EON payload | EN-IEC 62056-21 Mode D | Pow-P1 with RJ12 cable |
Note
Note 1: Please notify us if other countries should be added to the table!
Note 2: Might need USB power to operate. For Kamstrup Omnipower meters we recommend using Pow-K (without using the HAN-NVE module). Pow-U + RJ45 cable can be a solution in cases where there is no Wi-Fi coverage at the location of the power meter.
Note 3: Needs USB power to operate, as the Kamstrup HAN-P1 adapter does not deliver power. For Kamstrup Omnipower meters we recommend using Pow-K (without using the HAN-P1 module). A modified Pow-P1 + RJ12 cable can be a solution in cases where there is no Wi-Fi coverage at the location of the power meter.