Notifications
You must be signed in to change notification settings - Fork 27
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
feat: add autoware_control_center and autoware_node
Signed-off-by: M. Fatih Cırıt <[email protected]>
- Loading branch information
M. Fatih Cırıt
committed
Jul 19, 2024
1 parent
d02c63c
commit dc0fb55
Showing
46 changed files
with
2,045 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,61 @@ | ||
cmake_minimum_required(VERSION 3.8) | ||
project(autoware_control_center) | ||
|
||
find_package(autoware_cmake REQUIRED) | ||
autoware_package() | ||
|
||
ament_auto_add_library(${PROJECT_NAME} SHARED | ||
src/control_center_node.cpp | ||
src/include/control_center_node.hpp | ||
) | ||
|
||
# In order to instantiate only a single instance, we have to use custom main function | ||
#rclcpp_components_register_node(${PROJECT_NAME} | ||
# PLUGIN "autoware::control_center::ControlCenter" | ||
# EXECUTABLE ${PROJECT_NAME}_node | ||
#) | ||
|
||
ament_auto_add_executable(${PROJECT_NAME}_node | ||
src/control_center_main.cpp | ||
) | ||
|
||
if(BUILD_TESTING) | ||
# add_smoke_test(${PROJECT_NAME} ${PROJECT_NAME}_node | ||
# TEST_PARAM_FILENAMES "config/control_center.param.yaml" | ||
# ) | ||
|
||
install(DIRECTORY | ||
test/config/ | ||
DESTINATION share/${PROJECT_NAME}/test/config/ | ||
) | ||
|
||
file(GLOB_RECURSE TEST_FILES test/*.cpp) | ||
|
||
foreach(TEST_FILE ${TEST_FILES}) | ||
# Get the test name without directory and extension | ||
get_filename_component(TEST_NAME ${TEST_FILE} NAME_WE) | ||
|
||
# Add each test separately | ||
ament_add_ros_isolated_gtest(${TEST_NAME} ${TEST_FILE} TIMEOUT 10) | ||
target_include_directories(${TEST_NAME} PRIVATE src/include) | ||
target_link_libraries(${TEST_NAME} ${PROJECT_NAME}) | ||
ament_target_dependencies(${TEST_NAME} | ||
rclcpp | ||
rclcpp_lifecycle | ||
autoware_utils | ||
autoware_control_center_msgs) | ||
endforeach() | ||
|
||
# ament_add_ros_isolated_gtest(test_autoware_control_center ${TEST_SOURCES}) | ||
# target_include_directories(test_autoware_control_center PRIVATE src/include) | ||
# target_link_libraries(test_autoware_control_center ${PROJECT_NAME}) | ||
# ament_target_dependencies(test_autoware_control_center | ||
# rclcpp | ||
# rclcpp_lifecycle | ||
# autoware_utils | ||
# autoware_control_center_msgs) | ||
endif() | ||
|
||
ament_auto_package(INSTALL_TO_SHARE | ||
launch | ||
config) |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,99 @@ | ||
# Autoware Control Center | ||
|
||
## Abbreviations | ||
|
||
- **ACC:** Autoware Control Center | ||
- **AN:** Autoware Node | ||
|
||
## Overview | ||
|
||
The Autoware Control Center (ACC) is a core package within the Autoware system, designed to manage and monitor Autoware | ||
nodes (ANs). | ||
|
||
It provides services for the registration, de-registration, and error handling of ANs, as well as publishing reports on | ||
their status. | ||
|
||
ACC maintains an internal registry to keep track of registered ANs. | ||
|
||
## Interfaces | ||
|
||
### Services | ||
|
||
#### Register | ||
|
||
Registers an Autoware node to the ACC. | ||
|
||
- **Topic:** `/autoware/control_center/srv/register` | ||
- **Type:** `autoware_control_center_msgs::srv::Register` | ||
|
||
#### Deregister | ||
|
||
De-registers an Autoware node from the ACC. | ||
|
||
- **Topic:** `/autoware/control_center/srv/deregister` | ||
- **Type:** `autoware_control_center_msgs::srv::Deregister` | ||
|
||
### Subscribers | ||
|
||
#### Heartbeat (**Source:** Autoware Node) | ||
|
||
Subscribes to the heartbeat topic of an Autoware node after its registration. | ||
ACC controls the liveness of Autoware nodes by monitoring this topic. | ||
|
||
This topic also contains the information about the node's status. | ||
|
||
- **Topic:** `/autoware_node_name/heartbeat` | ||
- **Type:** `autoware_control_center_msgs::msg::Heartbeat` | ||
- **Source:** An Autoware Node | ||
|
||
### Publishers | ||
|
||
#### NodeReports | ||
|
||
Publishes reports on the current status of registered Autoware nodes. | ||
|
||
- **Topic:** `/autoware/control_center/node_reports` | ||
- **Type:** `autoware_control_center_msgs::msg::NodeReport` | ||
|
||
## Parameters | ||
|
||
| Name | Type | Default Value | Description | | ||
| --------------------- | -------- | ------------- | ----------------------------------------------------------------------------------- | | ||
| `lease_duration_ms` | `double` | `220.0` | If not received another heartbeat within this duration, AN will be considered dead. | | ||
| `report_publish_rate` | `double` | `1.0` | Publish NodeReports rate (hz) | | ||
|
||
## Singleton Constraint | ||
|
||
To ensure that only one instance of the ACC is running at any given time, two checks are performed in the main function: | ||
|
||
### 1. Lockfile Check | ||
|
||
This lockfile mechanism is fast and reliable for single-machine scenarios. | ||
It prevents multiple instances of ACC from running concurrently on the same machine. | ||
|
||
**Path:** `/tmp/autoware_control_center_node.lock` | ||
|
||
### 2. Network-Wide Node Name Check | ||
|
||
This involves gathering all node names and comparing them with the ACC node name (`/autoware/control_center`). | ||
While this method is slower and less reliable than the lockfile check, | ||
it is necessary for scenarios where the ACC is run across a network of machines. | ||
This ensures that no other instance of ACC is running on any other machine within the network. | ||
|
||
## Usage | ||
|
||
`ros2 launch autoware_control_center control_center.launch.xml` | ||
|
||
## Workflow | ||
|
||
When an Autoware Node starts, it registers itself with the ACC. | ||
|
||
The ACC then subscribes to the heartbeat topic of the Autoware node to monitor its liveness. | ||
|
||
If the ACC does not receive a heartbeat from the Autoware node within the specified lease duration, | ||
it considers the node to be dead. | ||
|
||
## Credits | ||
|
||
- Heartbeat functionality is based on ROS 2 [software_watchdogs](https://github.com/ros-safety/software_watchdogs) | ||
package. |
4 changes: 4 additions & 0 deletions
4
common/autoware_control_center/config/control_center.param.yaml
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,4 @@ | ||
/**: | ||
ros__parameters: | ||
deadline_ms: 220.0 | ||
report_publish_rate: 1.0 |
8 changes: 8 additions & 0 deletions
8
common/autoware_control_center/launch/control_center.launch.xml
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,8 @@ | ||
<?xml version="1.0" encoding="UTF-8"?> | ||
<launch> | ||
<arg name="param_path" default="$(find-pkg-share autoware_control_center)/config/control_center.param.yaml"/> | ||
|
||
<node pkg="autoware_control_center" exec="autoware_control_center_node" name="control_center" output="screen"> | ||
<param from="$(var param_path)"/> | ||
</node> | ||
</launch> |
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,34 @@ | ||
<?xml version="1.0"?> | ||
<?xml-model href="http://download.ros.org/schema/package_format3.xsd" schematypens="http://www.w3.org/2001/XMLSchema"?> | ||
<package format="3"> | ||
<name>autoware_control_center</name> | ||
<version>0.0.0</version> | ||
<description> | ||
Autoware Control Center (ACC) is an Autoware.Core package designed to manage | ||
and monitor Autoware nodes within a system. | ||
</description> | ||
<maintainer email="[email protected]">M. Fatih Cırıt</maintainer> | ||
<license>Apache-2.0</license> | ||
|
||
<buildtool_depend>ament_cmake_auto</buildtool_depend> | ||
<buildtool_depend>autoware_cmake</buildtool_depend> | ||
|
||
<depend>autoware_control_center_msgs</depend> | ||
<depend>autoware_utils</depend> | ||
<depend>lifecycle_msgs</depend> | ||
<depend>rclcpp</depend> | ||
<depend>rclcpp_components</depend> | ||
<depend>rclcpp_lifecycle</depend> | ||
|
||
<test_depend>ament_cmake_gtest</test_depend> | ||
<test_depend>ament_cmake_ros</test_depend> | ||
<test_depend>ament_lint_auto</test_depend> | ||
<test_depend>autoware_lint_common</test_depend> | ||
<test_depend>autoware_utils</test_depend> | ||
<test_depend>ros_testing</test_depend> | ||
<!-- <test_depend>autoware_testing</test_depend>--> | ||
|
||
<export> | ||
<build_type>ament_cmake</build_type> | ||
</export> | ||
</package> |
122 changes: 122 additions & 0 deletions
122
common/autoware_control_center/src/control_center_main.cpp
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,122 @@ | ||
// Copyright 2024 The Autoware Contributors | ||
// | ||
// Licensed under the Apache License, Version 2.0 (the "License"); | ||
// you may not use this file except in compliance with the License. | ||
// You may obtain a copy of the License at | ||
// | ||
// http://www.apache.org/licenses/LICENSE-2.0 | ||
// | ||
// Unless required by applicable law or agreed to in writing, software | ||
// distributed under the License is distributed on an "AS IS" BASIS, | ||
// WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. | ||
// See the License for the specific language governing permissions and | ||
// limitations under the License. | ||
|
||
#include "include/control_center_node.hpp" | ||
|
||
#include <rclcpp/rclcpp.hpp> | ||
|
||
#include <fcntl.h> | ||
#include <unistd.h> | ||
|
||
#include <algorithm> | ||
#include <memory> | ||
#include <string> | ||
|
||
const char * lock_file_path = "/tmp/autoware_control_center_node.lock"; | ||
|
||
int open_lock_file() | ||
{ | ||
// Open or create the lock file with read/write permissions | ||
int fd = open(lock_file_path, O_CREAT | O_RDWR, 0666); | ||
|
||
// Check if the file descriptor is valid | ||
if (fd == -1) { | ||
RCLCPP_FATAL(rclcpp::get_logger(""), "Failed to open lock file"); | ||
} | ||
return fd; | ||
} | ||
|
||
bool lock_file(int fd) | ||
{ | ||
struct flock fl = {F_WRLCK, SEEK_SET, 0, 0, 0}; | ||
// F_WRLCK: Write lock | ||
// SEEK_SET: Base the lock offset from the beginning of the file | ||
// 0, 0: Lock the entire file (start offset, length) | ||
|
||
// Attempt to set the file lock using fcntl | ||
if (fcntl(fd, F_SETLK, &fl) == -1) { | ||
// Check if the file is already locked by another process | ||
if (errno == EWOULDBLOCK) { | ||
RCLCPP_FATAL(rclcpp::get_logger(""), "Another instance is already running"); | ||
} else { | ||
// Handle other locking errors | ||
RCLCPP_FATAL(rclcpp::get_logger(""), "Failed to lock file"); | ||
} | ||
// Close the file descriptor on failure | ||
close(fd); | ||
return false; | ||
} | ||
return true; | ||
} | ||
|
||
void unlock_file(int fd) | ||
{ | ||
// Ensure the file descriptor is valid before closing | ||
if (fd != -1) { | ||
close(fd); | ||
} | ||
} | ||
|
||
bool node_already_exists(const std::string & node_name) | ||
{ | ||
auto temp_node = rclcpp::Node::make_shared("temp_node"); | ||
auto all_nodes = temp_node->get_node_names(); | ||
return std::find(all_nodes.begin(), all_nodes.end(), node_name) != all_nodes.end(); | ||
} | ||
|
||
int main(int argc, char * argv[]) | ||
{ | ||
bool use_lock_file = true; | ||
for (int i = 1; i < argc; ++i) { | ||
if (std::string(argv[i]) == "--dont-use-lock-file") { | ||
use_lock_file = false; | ||
break; | ||
} | ||
} | ||
rclcpp::init(argc, argv); | ||
|
||
// Lock file to prevent multiple instances on the same machine | ||
int lock_fd = -1; | ||
if (use_lock_file) { | ||
lock_fd = open_lock_file(); | ||
if (lock_fd == -1 || !lock_file(lock_fd)) { | ||
return 1; | ||
} | ||
} | ||
|
||
// Check if node already exists to prevent multiple instances across the network | ||
// It's a bit slow but better than nothing | ||
const std::string node_name_with_namespace = "/autoware/control_center"; | ||
if (node_already_exists(node_name_with_namespace)) { | ||
RCLCPP_FATAL( | ||
rclcpp::get_logger(""), "Node %s already exists", node_name_with_namespace.c_str()); | ||
if (use_lock_file) { | ||
unlock_file(lock_fd); | ||
} | ||
return 2; | ||
} | ||
|
||
// Instantiate the control center node, hopefully the only instance | ||
auto control_center = | ||
std::make_shared<autoware::control_center::ControlCenter>(rclcpp::NodeOptions()); | ||
rclcpp::executors::MultiThreadedExecutor exec; | ||
exec.add_node(control_center->get_node_base_interface()); | ||
exec.spin(); | ||
|
||
if (use_lock_file) { | ||
unlock_file(lock_fd); | ||
} | ||
rclcpp::shutdown(); | ||
return 0; | ||
} |
Oops, something went wrong.