Notifications
You must be signed in to change notification settings - Fork 1
Commit
This commit does not belong to any branch on this repository, and may belong to a fork outside of the repository.
git-svn-id: http://www.observium.org/svn/observer/trunk@2796 61d68cd4-352d-0410-923a-c4978735b2b8
- Loading branch information
sid3windr
committed
Dec 16, 2011
1 parent
879a59f
commit 346d071
Showing
1 changed file
with
351 additions
and
0 deletions.
There are no files selected for viewing
This file contains bidirectional Unicode text that may be interpreted or compiled differently than what appears below. To review, open the file in an editor that reveals hidden Unicode characters.
Learn more about bidirectional Unicode characters
Original file line number | Diff line number | Diff line change |
---|---|---|
@@ -0,0 +1,351 @@ | ||
BROADCOM-POWER-ETHERNET-MIB DEFINITIONS ::= BEGIN | ||
|
||
-- Copyright Broadcom Corporation (2003-2007) All rights reserved. | ||
|
||
-- This SNMP Management Information Specification | ||
-- embodies Broadcom Corporation's confidential and proprietary | ||
-- intellectual property. Broadcom Corporation retains all title | ||
-- and ownership in the Specification including any revisions. | ||
|
||
-- This Specification is supplied "AS IS", Broadcom Corporation | ||
-- makes no warranty, either expressed or implied, | ||
-- as to the use, operation, condition, or performance of the | ||
-- Specification. | ||
|
||
IMPORTS | ||
MODULE-IDENTITY, OBJECT-TYPE, Gauge32 FROM SNMPv2-SMI | ||
TruthValue FROM SNMPv2-TC | ||
fastPath FROM BROADCOM-REF-MIB | ||
pethPsePortEntry, pethMainPseEntry FROM POWER-ETHERNET-MIB; | ||
|
||
|
||
fastPathpowerEthernetMIB MODULE-IDENTITY | ||
LAST-UPDATED "200708191200Z" -- 17 Aug 2007 12:00:00 GMT | ||
ORGANIZATION "Broadcom Corporation" | ||
CONTACT-INFO | ||
" Customer Support | ||
Postal: Broadcom Corporation | ||
100 Perimeter Park Dr., Suite H | ||
Morrisville, NC 27560 | ||
Tel: +1 919 865 2700" | ||
|
||
DESCRIPTION | ||
"This MIB Augments the POWER-ETHERNET-MIB created by the IETF Ethernet | ||
Interfaces and Hub MIB Working Group for managing Power Source | ||
Equipment (PSE). The objects in this MIB are intended to provide | ||
additional objects for reporting information available to the hardware | ||
on this platform which are not represented in the draft MIB." | ||
|
||
-- Revision history. | ||
REVISION | ||
"200708191200Z" -- 17 Aug 2007 12:00:00 GMT | ||
DESCRIPTION | ||
"PoE support for BCM59101 added." | ||
REVISION | ||
"200705230000Z" -- 23 May 2007 12:00:00 GMT | ||
DESCRIPTION | ||
"Broadcom branding related changes." | ||
REVISION | ||
"200311101200Z" -- 10 Nov 2003 12:00:00 GMT | ||
DESCRIPTION | ||
"Initial revision." | ||
::= { fastPath 15 } | ||
|
||
agentPethObjects OBJECT IDENTIFIER ::= { fastPathpowerEthernetMIB 1 } | ||
|
||
agentPethPsePortTable OBJECT-TYPE | ||
SYNTAX SEQUENCE OF AgentPethPsePortEntry | ||
MAX-ACCESS not-accessible | ||
STATUS current | ||
DESCRIPTION | ||
"A table of per-port information and configuration objects relating | ||
to the power status of each port." | ||
::= { agentPethObjects 1 } | ||
|
||
agentPethPsePortEntry OBJECT-TYPE | ||
SYNTAX AgentPethPsePortEntry | ||
MAX-ACCESS not-accessible | ||
STATUS current | ||
DESCRIPTION | ||
"A collection of objects providing additional power information | ||
and control parameters for the specified port." | ||
AUGMENTS { pethPsePortEntry } | ||
::= { agentPethPsePortTable 1 } | ||
|
||
AgentPethPsePortEntry ::= SEQUENCE { | ||
agentPethPowerLimit | ||
Gauge32, | ||
agentPethOutputPower | ||
Gauge32, | ||
agentPethOutputCurrent | ||
Gauge32, | ||
agentPethOutputVolts | ||
Gauge32, | ||
agentPethTemperature | ||
Gauge32, | ||
agentPethPowerLimitType | ||
INTEGER, | ||
agentPethHighPowerEnable | ||
TruthValue, | ||
agentPethPowerDetectionType | ||
INTEGER, | ||
agentPethFaultStatus | ||
INTEGER, | ||
agentPethPortReset | ||
INTEGER | ||
} | ||
|
||
agentPethPowerLimit OBJECT-TYPE | ||
SYNTAX Gauge32 | ||
UNITS "Milliwatts" | ||
MAX-ACCESS read-write | ||
STATUS current | ||
DESCRIPTION | ||
"The configured maximum power this port can provide to an | ||
attached device measured in Milliwatts." | ||
::= { agentPethPsePortEntry 1 } | ||
|
||
agentPethOutputPower OBJECT-TYPE | ||
SYNTAX Gauge32 | ||
UNITS "Milliwatts" | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"The power this port is supplying to an attached device measured | ||
in Milliwatts." | ||
::= { agentPethPsePortEntry 2 } | ||
|
||
agentPethOutputCurrent OBJECT-TYPE | ||
SYNTAX Gauge32 | ||
UNITS "Milliamps" | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"The current this port is supplying to an attached device measured | ||
in Milliamps." | ||
::= { agentPethPsePortEntry 3 } | ||
|
||
agentPethOutputVolts OBJECT-TYPE | ||
SYNTAX Gauge32 | ||
UNITS "Volts" | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"The voltage this port is supplying to an attached device measured | ||
in Volts." | ||
::= { agentPethPsePortEntry 4 } | ||
|
||
agentPethTemperature OBJECT-TYPE | ||
SYNTAX Gauge32 | ||
UNITS "DEGREES" | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"The temperature measured at this port of the PoE Controller. It is | ||
measured in degree celcius." | ||
::= { agentPethPsePortEntry 5 } | ||
|
||
agentPethPowerLimitType OBJECT-TYPE | ||
SYNTAX INTEGER { | ||
dot3af(1), | ||
user(2) | ||
} | ||
MAX-ACCESS read-write | ||
STATUS current | ||
DESCRIPTION | ||
"Describes or controls the maximum power that a port can deliver | ||
A value of dot3af(1) means that the port power limit is as per | ||
the dot3af class of the PD attached. | ||
A value of user(2) means that the port power limit is equal to the value | ||
specified by agentPethPowerLimit" | ||
REFERENCE | ||
"Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6" | ||
|
||
::= { agentPethPsePortEntry 6 } | ||
|
||
agentPethHighPowerEnable OBJECT-TYPE | ||
SYNTAX TruthValue | ||
MAX-ACCESS read-write | ||
STATUS current | ||
DESCRIPTION | ||
"true (1) The PSE port can deliver power up to 32Watts. | ||
false(2) The PSE port can deliver power up to 18Watts" | ||
REFERENCE | ||
"Broadcom 5910X programmers guide" | ||
|
||
::= { agentPethPsePortEntry 7 } | ||
|
||
agentPethPowerDetectionType OBJECT-TYPE | ||
SYNTAX INTEGER { | ||
none(0), | ||
legacy(1), | ||
fourPtdot3afonly(2), | ||
fourPtdot3afandlegacy(3), | ||
twoPtdot3afonly(4), | ||
twoPtdot3afandlegacy(5) | ||
} | ||
MAX-ACCESS read-write | ||
STATUS current | ||
DESCRIPTION | ||
"Describes PD detection mechanism performed by the PSE port. | ||
A value of none(0) means no detection is done. | ||
A value of legacy(1) means only legacy capacitive detection scheme is | ||
used. | ||
A value of 4ptdot3afonly(2) means that IEEE 802.3af 4point detection scheme | ||
is used. | ||
A value of 4ptdot3afandlegacy(3)means that IEEE 802.3af 4point detection scheme | ||
is used and when that fails to detect a connected PD, legacity capacitive detection | ||
is used. | ||
A value of 2ptdot3afonly(4) means that IEEE 802.3af 2point detection scheme | ||
is used. | ||
A value of 2ptdot3afandlegacy(5)means that IEEE 802.3af 2point detection scheme | ||
is used and when that fails to detect a connected PD, legacity capacitive detection | ||
is used. | ||
The value 'none' can not be forcibly set by the administrator." | ||
REFERENCE | ||
"Broadcom 5910X programmers guide, IEEE Std 802.3af Section 30.9.1.1.6" | ||
|
||
::= { agentPethPsePortEntry 8 } | ||
|
||
agentPethFaultStatus OBJECT-TYPE | ||
SYNTAX INTEGER { | ||
none(0), | ||
mpsAbsent(1), | ||
short(2), | ||
overload(3), | ||
powerDenied(4) | ||
} | ||
MAX-ACCESS read-only | ||
STATUS current | ||
DESCRIPTION | ||
"Describes the error description when the pse port is in fault status. | ||
A value of none(0) specifies that the pse port is not in any error state. | ||
A value of mpsAbsent(1) specifies that the pse port has detected and absence | ||
of main power supply. | ||
A value of short(2) specifies that the pse port has detected a short circuit | ||
condition. | ||
A value of overload(3) specifies that the pd connected to the pse port had tried | ||
to draw more power than permissible by the hardware. | ||
A value of powerDenied(4) specifies that the pse port has been denied power | ||
because of shortage of power or due to administrative action." | ||
REFERENCE | ||
"Broadcom 5910X programmers guide, IEEE Std 802.3af" | ||
|
||
::= { agentPethPsePortEntry 9 } | ||
|
||
agentPethPortReset OBJECT-TYPE | ||
SYNTAX INTEGER { | ||
none(0), | ||
reset(1) | ||
} | ||
MAX-ACCESS read-write | ||
STATUS current | ||
DESCRIPTION | ||
"A value of reset(1) is used to move the pse port dot3af state to idle. A | ||
read on this object will always return the value none(0). The value none(0) | ||
can not be forcibly set by the administrtor." | ||
REFERENCE | ||
"Broadcom 5910X programmers guide, IEEE Std 802.3af" | ||
|
||
::= { agentPethPsePortEntry 10 } | ||
|
||
|
||
-- Main objects | ||
agentPethMainPseObjects OBJECT IDENTIFIER ::= { agentPethObjects 2 } | ||
|
||
agentPethMainPseTable OBJECT-TYPE | ||
SYNTAX SEQUENCE OF AgentPethMainPseEntry | ||
MAX-ACCESS not-accessible | ||
STATUS current | ||
DESCRIPTION | ||
"A table of objects that display and control attributes | ||
of the main power source in a PSE device. Ethernet | ||
switches are one example of boxes that would support | ||
these objects. | ||
Values of all read-write objects in this table are | ||
persistent at restart/reboot." | ||
::= { agentPethMainPseObjects 1 } | ||
|
||
agentPethMainPseEntry OBJECT-TYPE | ||
SYNTAX AgentPethMainPseEntry | ||
MAX-ACCESS not-accessible | ||
STATUS current | ||
DESCRIPTION | ||
"A set of objects that display and control the Main | ||
power of a PSE. " | ||
AUGMENTS { pethMainPseEntry } | ||
::= { agentPethMainPseTable 1 } | ||
|
||
AgentPethMainPseEntry ::= SEQUENCE { | ||
agentPethMainPseLegacy | ||
TruthValue | ||
} | ||
|
||
agentPethMainPseLegacy OBJECT-TYPE | ||
SYNTAX TruthValue | ||
MAX-ACCESS read-write | ||
STATUS current | ||
DESCRIPTION | ||
"Enable/Disable Legacy device detection. The | ||
value true(1) means legacy devices are detected; the | ||
value false(2) means legacy devices are not detected." | ||
::= { agentPethMainPseEntry 1 } | ||
|
||
agentPethPseTable OBJECT-TYPE | ||
SYNTAX SEQUENCE OF AgentPethPseEntry | ||
MAX-ACCESS not-accessible | ||
STATUS current | ||
DESCRIPTION | ||
"A table of per-unit information and configuration objects relating | ||
to the power configurtion for the entire pse unit." | ||
::= { agentPethObjects 3 } | ||
|
||
agentPethPseEntry OBJECT-TYPE | ||
SYNTAX AgentPethPseEntry | ||
MAX-ACCESS not-accessible | ||
STATUS current | ||
DESCRIPTION | ||
"A collection of objects providing additional power information | ||
and control parameters for the specified pse unit." | ||
AUGMENTS { pethMainPseEntry } | ||
::= { agentPethPseTable 1 } | ||
|
||
AgentPethPseEntry ::= SEQUENCE { | ||
agentPethPsePowerManagementMode | ||
INTEGER, | ||
agentPethPseAutoResetEnable | ||
TruthValue | ||
} | ||
|
||
agentPethPsePowerManagementMode OBJECT-TYPE | ||
SYNTAX INTEGER { | ||
none(0), | ||
dynamic(1), | ||
static(2) | ||
} | ||
MAX-ACCESS read-write | ||
STATUS current | ||
DESCRIPTION | ||
"Describes or controls the power management algorithm used by the pse | ||
to deliver power to the requesting PDsthat a pds. | ||
A value of dot3af(1) means that the port power limit is as per | ||
the dot3af class of the PD attached. | ||
A value of user(2) means that the port power limit is equal to the value | ||
specified by agentPethPowerLimit" | ||
REFERENCE | ||
"Broadcom 5910X programmers guide" | ||
|
||
::= { agentPethPseEntry 1 } | ||
|
||
agentPethPseAutoResetEnable OBJECT-TYPE | ||
SYNTAX TruthValue | ||
MAX-ACCESS read-write | ||
STATUS current | ||
DESCRIPTION | ||
"true (1) The PSE port is reset with out administrator intervention whenver a | ||
fault condition occurs. | ||
false(2) Administrator has to reset the pse port whenver a fault condition | ||
is detected." | ||
|
||
::= { agentPethPseEntry 2 } | ||
END |