[3.7.0] October 27 2024

IMPORTANT! BREAKING CHANGES with 3.6.5

  • "ww" and "wwc" has been renamed to "dhw". It is nested JSON object in both the MQTT and API outputs. The old prefix has also been removed from MQTT topics (#1634). This will impact historical data in home automation systems like Home Assistant and IOBroker. To preserve the current value of dhw energy (was previously nrgww) refer to this issue #1938.
  • dhw entities from the MM100/SM100 have been moved under a new Device called 'water'.
  • The automatically generated temperature sensor ID has replaced dashes (-) with underscores (_) to be compatible with Home Assistant.
  • api/system/info has it's JSON key names changed to camelCase syntax.

For more details go to www.emsesp.org

Added

  • some more entities for dhw with SM100 module
  • thermostat second dhw circuit #1634
  • remote thermostat emulation for RC100H, RC200 and FB10 #1287, #1602, #1551
  • heatpump dhw stop temperatures #1624
  • reset history #1695
  • heatpump entities fan and shutdown #1690
  • mqtt HA-mode 3 for v3.6 compatible HA entities, set on update v3.6->v3.7
  • HP input states #1723
  • holiday settings for rego 3000 #1735
  • Added scripts for OTA (scripts/upload.py and upload_cli.py) #1738
  • timeout for remote thermostat emulation #1680, #1774
  • CR120 thermostat as own model() #1779
  • modules - external linkable module library #1778
  • scheduler onChange and Conditions #1806
  • make remote control timeout editable #1774
  • added extra pump characteristics (mode and pressure for EMS+) by @SLTKA #1802
  • allow device name to be customized #1174
  • Modbus support by @mheyse #1744
  • System Message command #1854
  • scheduler can use web get/post for values and commands #1806
  • RT800 remote emulation #1867
  • RC310 cooling parameters #1857
  • command api/device/entities #1897
  • switchprogmode #1903
  • autodetect and download firmware upgrades via the WebUI
  • command 'show log' that lists out the current weblog buffer, showing last messages.
  • default web log buffer to 25 lines for ESP32s with no PSRAM
  • try and determine correct board profile if none is set during boot
  • auto Scroll in WebLog UI - reduced delay so incoming logs are faster
  • uploading custom support info, shown to Guest users in Help page #2054
  • feature: Dashboard showing all data (favorites, sensors, custom) #1958
  • entity for low-temperature boilers pump start temp (pumpOnTemp) #2088 #2088
  • internal ESP32 temperature sensor on the S3 #2077
  • MQTT status topic (used in connect and last will) set to Retain #2086
  • Czech language 2096
  • Developer Mode and send EMS Read Commands from WebUI #2116
  • Scheduler functions #2115
  • Set device custom name from telegram 0x01 #2073

Fixed

  • remote thermostat emulation for RC200 on Rego2000/3000 thermostats #1691
  • log shows data for F7/F9 requests
  • Detection of LittleFS for factory setting wasn't working
  • Check for bad GPIOs with Ethernet before the ethernet is initialized
  • Show values with factor 50 on webUI #2064
  • Rendering of values between -1 and 0
  • Value for 32bit times not-set #2109

Changed

  • use flag for BC400 compatible thermostats, manage different mode settings
  • use factory partition for 16M flash
  • store digital out states to nvs
  • Refresh UI - moving settings to one location #1665
  • rename DeviceValueTypes, add UINT32 for custom entities
  • dynamic register dhw circuits for thermostat
  • removed OTA feature #1738
  • added shower min duration #1801
  • Include TXT file along with the generated CSV for Device Data export/download
  • thermostat/remotetemp as command #1835
  • temperaturesensor id notation with underscore #1794
  • Change key-names in JSON to be compliant and consistent #1860
  • Updates to webUI #1920
  • Correct firmware naming #1933 #1933
  • Don't start Serial console if not connected to a Serial port. Will initiate manually after a CTRL-C/CTRL-S
  • WebLog UI matches color schema of the terminal console correctly
  • Updated Web libraries, ArduinoJson
  • Help page doesn't show detailed tech info if the user is not 'admin' role #2054
  • removed system command allvalues and moved to an action called export
  • Show ems-esp internal devices in device list of system/info
  • Scheduler and mqtt run async on systems with psram
  • Show IPv6 address type (local/global/ula) in log