Skip to content

Releases: johanmazoyer/Asterix

v0.1.1

07 Feb 12:34
a90600b
Compare
Choose a tag to compare

Full description in #156

Description

First release that covers both the FQPM (tested on W7 component) and the WV (tested on Pos5 component).

WV tests performed on 02 February 2023. FQPM tests performed on 03 February 2023.

Hardware and software tests

The number of modes indicated in the table assume the usage of the 8.1 mm Lyot stop.

FDH, 2-DM control
600 modes
FDH, DM3 control
300 modes
HDH, DM3 control
300 modes
FQPM sim
FQPM hw
WV sim
WV hw

FQPM ... four-quadrant phase-mask coronagraph
WV ... wrapped vortex coronagraph
hw ... hardware -> on the THD2 testbed
sim ... simulations
DM3 ... the in-pupil DM

✅ ... tested
🟡 ... untested

v0.1.0

24 Jan 17:03
1f69a41
Compare
Choose a tag to compare

Full description in #154

Description

Preparing a release that fully works on the THD2 testbed following work on Wed, 18 January 2023.

The tests for this release were done on Tuesday, 24 January 2023.

Since this is our first formal release, we focused on testing the FQPM coronagraph only and leave WV work for a later date.

Hardware and software tests

FDH, 2-DM control
600 modes
FDH, DM3 control
300 modes
HDH, DM3 control
300 modes
FQPM sim
FQPM hw
WV sim 🟡 🟡 🟡
WV hw 🟡 🟡 🟡

FQPM ... four-quadrant phase-mask coronagraph
WV ... wrapped vortex coronagraph
hw ... hardware -> on the THD2 testbed
sim ... simulations
DM3 ... the in-pupil DM

✅ ... tested
🟡 ... untested

v0.1.0-alpha

18 Jan 14:56
a7cdbb2
Compare
Choose a tag to compare
v0.1.0-alpha Pre-release
Pre-release

First hardware release for THD2 testbed

Checked requirements

FQPM coronagraph

  • created matrix from default values on repo for FQPM, no need to change a single parameter, no errors; needs to run fast enough for debugging
  • tested half DH matrix for FQPM on hardware, and simulation (converging EFC loop)
  • tested full DH matrix for FQPM on hardware, and simulation (converging EFC loop)

Wrapped Vortex coronagraph

  • created matrix for WV while only parameters changed are corona_type, wavelength_0, Science_sampling, without errors; needs to run fast enough for debugging
  • tested half DH matrix for WV on hardware, and simulation (converging EFC loop)
  • tested full DH matrix for WV on hardware, and simulation (converging EFC loop)

General

  • matrices successfully tested on testbed have been saved to permanent interaction matrix folder on lab machine

Notes

This is supposed to be an intermediary release on our way to create a first release with all boxes above checked.