Updating mail pack preparation SOP
Browse files Browse the repository at this point in the history
  • Loading branch information
peterhcharlton committed Jan 11, 2024
1 parent 63badbf commit 8c2a6d8
Show file tree
Hide file tree
Showing 2 changed files with 36 additions and 11 deletions.
Original file line number Diff line number Diff line change
@@ -1,15 +1,15 @@
---
layout: default
title: 3.01 Participation - Device Preparation
title: 3.01 Participation - Device Setup
parent: SOPs
grand_parent: SAFER Wearables
has_children: false
---

# Device Preparation
# Device Setup
{: .no_toc }

This page provides details of how devices are prepared to be sent to participants of the SAFER Wearables Study.
This page provides details of how devices are setup ready to be sent to participants of the SAFER Wearables Study.
{: .fs-6 .fw-300 }

## Table of contents
Expand All @@ -20,6 +20,10 @@ This page provides details of how devices are prepared to be sent to participant

---

## Cleaning

All devices should be cleaned using wipes.

## Bittium Faros 180

1. Connect the device to a Windows PC via USB.
Expand Down
37 changes: 29 additions & 8 deletions safer_wearables/sops/participation/mail_pack_preparation.md
Original file line number Diff line number Diff line change
Expand Up @@ -6,7 +6,7 @@ grand_parent: SAFER Wearables
has_children: false
---

# Sending Mail Packs
# Mail Pack Preparation
{: .no_toc }

This page describes how to put together a Mail Pack to be sent to a participant.
Expand All @@ -20,22 +20,43 @@ This page describes how to put together a Mail Pack to be sent to a participant.

---

## Device setup
## Preparation

Ensure the devices have been setup as detailed in the [device setup SOP](./device_preparation). Currently, we are using the following three devices:
Ensure the devices have been setup as detailed in the [Device Setup SOP](./device_setup). Currently, we are using the following three devices:
- Bittium Faros 180
- PulseOn OHR Tracker
- PulseOn Arrythmia Monitor

## Printing

Ensure that the following are printed:
- 2 x return labels
- Instruction leaflet
- Questionnaire (including the participant ID)

## Prepare mail pack

Prepare a mail pack consisting of:
Prepare two bags each consisting of:
- Bag: currently using polyethene bags measuring 350x405 mm
- Return address label: a label on each bag stating "If undelivered please return to: SAFER Wearables Study; Strangeways Research Laboratory; 2 Worts Causeway; Cambridge; CB1 8RN".


Prepare a device box consisting of:
- A cardboard box (currently using brown boxes measuring 240x240x40mm)
- Foam inserts (currently using three pieces of foam: one at the bottom and top measuring 6 mm thick, and a middle layer measuring 25mm thick).
- Bags: one for outward, and one for return (currently using polyethene measuring 350x405 mm). Both with return address labels.
- Instruction leaflet
- Questionnaire
- Three wearable devices (already set up)
- Charger for the PulseOn Arrythmia Monitor
- Check that there is an electrode cable already in the Bittium Faros device
- Electrodes in an envelope (8 electrodes)
Selotape the device box shut.

Prepare a return envelope consisting of:
- Questionnaire
- Return bag (with return label)
- A5 Envelope stating "To open when ready to return devices. Contains: (i) Questionnaire; (ii) Return bag (for the box to be put in)."
Put the questionnaire and return bag in the envelope, and selotape it shut. Then selotape the return envelope to the device box.


Prepare a mail pack by taking the remaining bag and putting in it:
- Device box
- Instruction leaflet
- Chest dots envelope

0 comments on commit 8c2a6d8