Add more flux units for SB conv
Browse files Browse the repository at this point in the history
Fix test and some indentations
  • Loading branch information
pllim committed Jan 15, 2025
1 parent 87016c7 commit 0e16917
Show file tree
Hide file tree
Showing 2 changed files with 21 additions and 10 deletions.
2 changes: 2 additions & 0 deletions CHANGES.rst
Original file line number Diff line number Diff line change
Expand Up @@ -64,6 +64,8 @@ Cubeviz

- Fixed copious warnings from spaxel tool when data has INF. [#3368]

- Fixed unit conversion for certain units when Surface Brightness is selected. [#3389]

Imviz
^^^^^

Expand Down
29 changes: 19 additions & 10 deletions jdaviz/utils.py
Original file line number Diff line number Diff line change
Expand Up @@ -326,9 +326,19 @@ def standardize_roman_metadata(data_model):


def indirect_units():
from jdaviz.core.custom_units_and_equivs import PIX2
from jdaviz.core.unit_conversion_utils import supported_sq_angle_units

units = []
# Only PIX2 here because sr would mess with PIXAR_SR stuff from JWST.
units = [
u.Jy / PIX2,
u.MJy / PIX2,
u.mJy / PIX2,
u.uJy / PIX2,
u.W / (u.Hz * u.m**2 * PIX2),
u.eV / (u.Hz * u.s * u.m**2 * PIX2),
u.ct / PIX2
]

for angle_unit in supported_sq_angle_units():
units += [
Expand Down Expand Up @@ -418,11 +428,10 @@ def flux_conversion(values, original_units, target_units, spec=None, eqv=None, s
solid_angle_in_targ = check_if_unit_is_per_solid_angle(targ_units, return_unit=True)

# Ensure a spectrum passed through Spectral Extraction plugin
if ((((spec and ('_pixel_scale_factor' in spec.meta))) or
(spectral_axis is not None and ('_pixel_scale_factor' in spectral_axis.info.meta)))
and
(((solid_angle_in_orig) and (not solid_angle_in_targ)) or
((not solid_angle_in_orig) and (solid_angle_in_targ)))):
if (((spec and ('_pixel_scale_factor' in spec.meta)) or
(spectral_axis is not None and ('_pixel_scale_factor' in spectral_axis.info.meta))) and
((solid_angle_in_orig and (not solid_angle_in_targ)) or
((not solid_angle_in_orig) and solid_angle_in_targ))):
# Data item in data collection does not update from conversion/translation.
# App-wide original data units are used for conversion, original and
# target_units dictate the conversion to take place.
Expand Down Expand Up @@ -456,9 +465,9 @@ def flux_conversion(values, original_units, target_units, spec=None, eqv=None, s
# additional conversions to reach the desired end unit.
# if spec_unit in [original_units, target_units]:
result = _indirect_conversion(
values=values, orig_units=orig_units, targ_units=targ_units,
eqv=eqv, spec_unit=spec_unit
)
values=values, orig_units=orig_units, targ_units=targ_units,
eqv=eqv, spec_unit=spec_unit
)

if result and len(result) == 2:
values, updated_units = result
Expand Down Expand Up @@ -523,7 +532,7 @@ def _indirect_conversion(values, orig_units, targ_units, eqv,
targ_units /= solid_angle_in_spec
solid_angle_in_targ = solid_angle_in_spec
if ((u.Unit(targ_units) in indirect_units()) or
(u.Unit(orig_units) in indirect_units())):
(u.Unit(orig_units) in indirect_units())):
# SB -> Flux -> Flux -> SB
temp_orig = orig_units * solid_angle_in_orig
temp_targ = targ_units * solid_angle_in_targ
Expand Down