P1 Modbus load balancer

Modbus registers

Register R/W Description Resolution Unit Default
1000 RW Override the current load balancer limit (applied directly) 0.001 A 16 A
1001 R The current limit decided by the load balancer 0.001 A
1002 R The current load balancer state
1010 RW The maximum charger current of the charger 0.001 A 16 A
1011 RW Number of phases 3
1012 RW Alarm limit current 0.001 A 24 A
1013 RW Alarm limit wait time 1 second 1 s
1014 RW Alarm limit current change amount 0.001 A 12.5A
1015 RW Upper limit current 0.001 A 22 A
1016 RW Upper limit wait time 1 second 5 s
1017 RW Upper limit current change amount 0.001 A 1 A
1018 RW Lower limit current 0.001 A 19 A
1019 RW Lower limit wait time 1 second 1 s
1020 RW Lower limit current change amount 0.001 A 1 A
1021 RW Fallback limit 0.001 A 0 A
1022 RW Fallback limit time 1 second 30 s
1090 W Change the modbus server address 10
1091 W Save and apply configuration (write 1)
1092 W Restore defaults (write 1)

The defaults are bases on an 11 kW charger on an 3 phase 25 A grid connection.

Load balancer state

State Description LED Indication
0 Normal ._______ (1 pulse per second)
1 Lower limit ._._____ (2 pulses per second)
2 Upper limit ._._.___ (3 pulses per second)
3 Alarm limit ._._._._ (4 pulses per second)
4 Fallback/Error ----____ (0.5 sec on, 0.5 sec off)

diagslave -m rtu -b 9600 -p none /dev/ttyUSB0 modpoll -a 1 -0 -r 1000 -t 4 -1 -b 9600 -p none /dev/ttyACM1

Schematic and PCB are available on https://oshwlab.com/timstegeman/p1_modbus_loadbalancer